Date Description Inspector Results Comments
03/13/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
REVISED APPROVED PLAN ON SITE
(1) IN HOUSE BACKFLOW CERTIFICATION TURNED IN
GAS CARD AT METER
03/12/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) YARD WATER COVERED WITHOUT INSPECTION
2) AVB'S ARE NOT INSTALLED UNTIL RETAINING SCREW IS BROKEN
3) DOOR LOCKED-NO ACCESS
06/20/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection 1) SANITARY DRAINAGE SYSTEM UNDERGROUND ONLY WATER TEST TO 10' ABOVE FINISH FLOOR OK PENDING CITY APPROVAL OF RED LINE DRAWING ON SITE. COVER AT OWN RISK. WILL REQUIRE INSTALLATION OF FIXTURE DRAINAGE FITTINGS AND VENT THRU ROOF TEST AT FUTURE DATE
2) CALL IN FOR PIPE WRAP INSPECTION PRIOR TO CONCRETE POUR BACK
3) GREASE WASTE REQUIRES DIRECTIONAL FITTING FOR CLEANOUT ON DOWN STREAM SIDE, CORRECT INSTALLATION ON GREASE TRAP TO GREASE WASTE PIPING. I.E. PIPING AND TRAP SHOULD BE SAME PIPE SIZE. DO NOT COVER GREASE WASTE SYSTEM