Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM01569
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* REVISED APPROVED PLAN ON SITE (1) IN HOUSE BACKFLOW CERTIFICATION TURNED IN GAS CARD AT METER |
|
03/12/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) YARD WATER COVERED WITHOUT INSPECTION 2) AVB'S ARE NOT INSTALLED UNTIL RETAINING SCREW IS BROKEN 3) DOOR LOCKED-NO ACCESS |
|
06/20/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | 1) SANITARY DRAINAGE SYSTEM UNDERGROUND ONLY WATER TEST TO 10' ABOVE FINISH FLOOR OK PENDING CITY APPROVAL OF RED LINE DRAWING ON SITE. COVER AT OWN RISK. WILL REQUIRE INSTALLATION OF FIXTURE DRAINAGE FITTINGS AND VENT THRU ROOF TEST AT FUTURE DATE 2) CALL IN FOR PIPE WRAP INSPECTION PRIOR TO CONCRETE POUR BACK 3) GREASE WASTE REQUIRES DIRECTIONAL FITTING FOR CLEANOUT ON DOWN STREAM SIDE, CORRECT INSTALLATION ON GREASE TRAP TO GREASE WASTE PIPING. I.E. PIPING AND TRAP SHOULD BE SAME PIPE SIZE. DO NOT COVER GREASE WASTE SYSTEM |