Permit: T04CM03185
Permit Details
Status:
Final
Type:
MULTI FAMILY NEW
Address:
3121 E BELLEVUE ST #01
Address NEW:
3121 E BELLEVUE ST #01
Apply Date:
07/09/2004
Applicant:
ARQUITECTO- ORNELAS & ASSOCIATES
Description:
NEW:FOURPLEX
Contractors:
- MARDI S CONSTRUCTION
Permit Reviews
Permit Number - T04CM03185
Permit Status: Final
Permit Description: NEW:FOURPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/06/2005 | RESUBMITTAL - SITE ALL | 04/12/2005 | COMPLETED |
| 05/02/2005 | RESUBMITTAL | 05/25/2005 | COMPLETED |
| 05/25/2005 | RESUBMITTAL | 06/06/2005 | COMPLETED |
| 06/06/2005 | RESUBMITTAL | 07/14/2005 | COMPLETED |
| 07/09/2004 | PLANS OK TO SUBMIT - 3RD PARTY | 07/19/2004 | COMPLETED |
| 07/09/2004 | PLANS OK TO SUBMIT - SITE | 07/19/2004 | COMPLETED |
| 07/19/2004 | SITE | 08/16/2004 | COMPLETED |
| 07/19/2004 | 3RD PARTY REVIEW-COMMERCIAL | 10/25/2004 | COMPLETED |
| 09/15/2004 | RESUBMITTAL - SITE ALL | 10/13/2004 | COMPLETED |
| 10/25/2004 | COMMERCIAL NEW | 12/07/2004 | COMPLETED |
| 11/08/2004 | RESUBMITTAL - SITE ALL | 12/07/2004 | COMPLETED |
| 11/18/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 11/18/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03185
Permit Status: Final
Permit Description: NEW:FOURPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/09/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T04CM03185
Permit Description: NEW:FOURPLEX
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) ABS DWV UNDERGROUND OK 2) CONNECTION TO SITE SEWER OK 3) OK TO COVER |
| 08/16/2005 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* 1) 20' OF #2 COPPER UFER |
| 08/16/2005 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/16/2005 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/16/2005 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/21/2005 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection :* ROOF LINE CLIPS OK |
| 12/06/2005 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection :* SOIL WATER TEST IS OK DWV SYSTEM IS OK OVERHEAD WATER DISTRIBUTION IS OK GAS PRESSURE TEST IS OK FINAL CONNECTION OF YARD WATER LINE TO BLDG SERVICE IS OK TO BACKFILL. |
| 12/06/2005 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection :* |
| 12/06/2005 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection :* |
| 12/08/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR SHEETROCK |
| 12/09/2005 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/09/2005 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/20/2005 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK OUTDOOR HOUSE LIGHTING |
| 12/20/2005 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :*APPROVED |
| 12/20/2005 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
| 12/21/2005 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | APPROVED |
| 01/30/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/27/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/24/2006 | SITE - SEWER | RMYERS | Approved | |
| 03/24/2006 | PLUMBING - PROGRESS | RMYERS | Approved | 1. SEWER APPROVED BY T. VALENCIA 2. YARDWATER CONNECTED TO METER OK OK TO COVER |
| 04/13/2006 | TEP CLEARANCE - PM | JWEATHER | Approved | CEC CLEARED FOR UNITS #1, 2, 3 & 4 PER R. MAJUTA |
| 04/13/2006 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection :* |
| 06/26/2006 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK 2) OK FOR C OF PENDING ANY OTHER INSPECTION |
| 06/26/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 06/27/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR UNITS #1, #2, #3 & #4 PER C. CLEMENS |
| 07/12/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 07/19/2006 | FIRE - FINAL | LTHOMAS | Approved | |
| 07/21/2006 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 08/04/2006 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL |
| 08/14/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 08/14/2006 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 08/14/2006 | ELECTRIC - PROGRESS | CCLEMENS | Approved | IVRS - Inspection :* |
| 08/15/2006 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/16/2006 | PERMIT FINALED | BFLORES | Approved | |
| 08/16/2006 | ENGINEERING - FINAL | MRUSSO | Approved |