Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/14/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/20/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK OUTDOOR HOUSE LIGHTING |
|
| 12/08/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ADD SMOKE DETECTOR IN EACH UPSTAIRS HALLWAY 2) OK TO COVER ELECTRICAL AFTER SMOKE DETECTORS INSTALLED 3) BOND GAS AND WATER TO SERVICE |
|
| 12/06/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*ALL UNITS ONLY 1 NEUTRAL PER SCREW IN SUB PANEL HAVE 12 GA?/AND 14 GAL WIRE ON SMOKE DET. RUN? ( 15 AMP MAX) AND 3 WAY CKT'S MAKE SURE ALL ROMEX SHEATHING ENTERS PANEL/BOX'S BATH CKT'S TO BE ON OWN CKT'S OR DONT LEAVE BATH'S ( GFI) INSTALL ADDITIONAL NAIL PLATED AS NEEDED IF CEILING FANS ARE INSTALLED, USE FAN RATED BOX'S |