Permit: T01CM02566
Permit Details
Apply Date:
05/29/2001
Applicant:
BAY CITIES STEVE
Description:
TI:CHARTER SCHOOL
Contractors:
- CAPITAL CONSTRUCTION L L C ,
Permit Reviews
Permit Number - T01CM02566
Permit Status: C of o
Permit Description: TI:CHARTER SCHOOL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/13/2002 | REVISION | 02/13/2002 | COMPLETED |
| 05/29/2001 | 3RD PARTY COMMERCIAL TI | 06/06/2001 | COMPLETED |
| 05/30/2002 | SITE | 05/31/2002 | COMPLETED |
| 08/29/2001 | REVISION | 08/30/2001 | COMPLETED |
| 09/06/2001 | REVISION | 09/06/2001 | COMPLETED |
| 09/27/2001 | REVISION | 09/27/2001 | COMPLETED |
| 10/10/2001 | REVISION | 10/10/2001 | COMPLETED |
| 12/17/2001 | REVISION | 01/24/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM02566
Permit Status: C of o
Permit Description: TI:CHARTER SCHOOL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/29/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM02566
Permit Description: TI:CHARTER SCHOOL
Total Completed Inspections - 33
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
| 06/29/2001 | ELECTRIC - INTERMEDIATE | JORTA | Approved | E-4OK,E2 OK TO COVER WALLS S E1 NOT READY STRAP INSTALL PANCEL |
| 07/06/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/01/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/01/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) INTERMEDIATE AT KITCHEN OK DWV OK WATER TEST TO 10' OK COOPER OK PRESSURE OK 2.) GREASE TRAP OK 3.) OK TO BACKFILL OK FOR SHEETROCK. |
| 08/02/2001 | SHEET ROCK NAILING | DWITT | Approved | IVRS - Inspection 0000* |
| 08/03/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/08/2001 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*1.) PLUMBING ABOVE CEILING OK 2.) REPAIR TO BROKEN 4"ABS OK SOUTHSIDE OF BLDG. |
| 08/13/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/19/2001 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/20/2001 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/20/2001 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000*APPROVED FOR TEMP POWER. |
| 08/21/2001 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) BLDG SEWER FROM KITCHEN TO TIE-IN ON MAIN OK OK TO BACKFILL. 2.) PLUMBING YARDWATER OK PRESSURE TEST OK. |
| 08/27/2001 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0999*1. WILL NEED OFFICE TO EXAMINE CONTENTS OF LETTER ON ACCEPTANCE OF (A) SQUARE 'D" SIDE ENTRY INTO SWITHGEAR NOT NORMALLY DESIGNED FOR SIDE ENTRY (B) NEED LETTER DESCRIBING METHOD OF GROUNDING TO USE (UFER MISSED) (C) SHOW DERATE OF CONDUCTORS FOR EXTERIOR FEEDER .2. BOLT DOWN SWITCH GEAR 3. TEMP LETTER AT OFFICE. |
| 08/28/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 08/29/2001 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 08/29/2001 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 08/29/2001 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 08/30/2001 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | BUILDING A AND C ONLY O.K. TEMP C OF O. 1.) COMPLETE HALL EXISTS AND LIGHTING 2.) COMPLETE ROOF TOP EQUIPMENT CONDUIT NOT SUPPORTED AND CLEANANCE @ ONE LOCATION. 3.) BARRICADE PER BUILD INSPECT REQUIREMENT. |
| 09/10/2001 | LANDSCAPE - FINAL | PGILBERT | Approved | COMPLETE LANDSCAPING PER PLAN. PROTECTION FOR PLANTS REQUIRED IN PARKING LOT. RECOUNT OF PIP NEEDED; MONITORING REPORT REQUIRED. |
| 09/28/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*PA TEMP POWER FOR TESTING. |
| 09/30/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*FOR TEMP POWER.1.) OK FOR TEMP POWER. |
| 10/01/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 10/04/2001 | ELECTRIC - ABOVE CEILING | JORTA | Approved | ABOVE CEILING BUILD D 1ST AND 2ND FLOOR APPROVED PLEASE EXPOSED ALL AIR HANDLING METER AHU 5 IMPROPER WIRE SIZE IMPROPER WIRING METHOD MARK ON NAME PLATE ALL AUXILARY DEVICES BEING UTILIZED INSTALL COVER. |
| 10/25/2001 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0999*1.) NEED ACCURATE CITY APPROVED AND UNDERSTANDABLE REVISION. ELECTRICAN TO CHECK ALL FOR CODE VIOLATION ABOVE CIELING CONDUITS, SIEISMIC TIES, FAULT CURRENT, PANEL BOARD CONCUIT NO INSPECTION UNTIL EVERY THING IS FIXED AND ACCURATE. |
| 01/11/2002 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 02/14/2002 | ELECTRIC - TEMPORARY POLE | JORTA | Approved | |
| 02/14/2002 | ELECTRIC - UNDERGROUND | JORTA | Approved | |
| 02/14/2002 | ELECTRIC - UFER | JORTA | Approved | |
| 02/19/2002 | MECHANICAL - HOODS | CWILLIAM | Approved | |
| 06/19/2002 | ENGINEERING - FINAL | DROBERTS | Approved | TEMPORARY C OF O APPROVED, FINAL NOT TO BE GIVEN UNTIL THE FINAL GRADING INSPECTION #9190 FOR TOOBU00724 IS COMPLETE AND ACCEPTED. |
| 09/24/2002 | HEALTH DEPT - FINAL 724-7908 | HEALTH | Approved | |
| 05/23/2003 | PERMIT FINALED | PGILBERT | Approved |