Permit: T01CM02566

Parcel: 137105120


Addresses:

5660 S 12TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T01CM02566

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/14/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS.
02/08/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) INSTALL APPROVED C.O. ADPT AND PLUG ON SEWER. 2.) STRAP EXPANSION TANK 3.) KITCHEN EQUIPMENT NOT INSTALLED PER PLAN 4.) NEED TO SEE CERTIFICATION FOR RPBB.
09/30/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*FOR TEMP POWER.1.) OK FOR TEMP POWER.
09/12/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) ADMIN BLDG "A" AND CLASSROOMS "C" 1.) ALL CORRECTIONS MADE OK 2.) THE GANG BATHROOM BETWEEN "A" & "C" COMPLETE 3.) NO CORRECTIONS REQ'D THIS AREA ONLY.
09/10/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*A.) ADMIN AND BLDG "A" CORRECTIONS 1.) URINALS REQUIRE CLEAN-OUTS 2.) 17" AFF MAX FOR H.C. URINAL. 3.) REDUCING PAN DRAIN FROM 1" TO 3/4" CONSIDERED AN OBSTRUCTION. 4.) DRINKING FOUNTAINS NOT INSTALLED 5.) CUT DOWN CLEAN-OUTS OURTSIDE BATHROOMS AND REPLACE RAISED SQ HEAD PLUG TO ELIMINATE TRIPPING HAZZARD 6.) PAN DRAIN, AND T & P RELIEF DRAIN TERMINATION NOT APPROVED OVER CONCRETE SIDE WALK.
09/07/2001 PLUMBING - FINAL Partial Approval 1.) BLDG "B" PLUMBING FINAL OK 2.) NO CORRECTIONS REQUIRED.
09/06/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) BLDG "B" VENTS NOT FLASHED PER PLAN.
08/29/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SOMEBODY INITIALED CHANGES FROM THE APPROVED PLAN. . RE-SUBMIT INITIALED PLAN FOR CITY APPROVAL. 2.) WHERE IS REVISED PLAN FOR ADDED PLUMBING FIXTURES IN THE BATHROOMS? 3.) NO BATHROOM GROUPS READY FOR INSPECTION 4.) IF THE ARCHETECT IS GOING TO INITIAL CHANGES TO PLAN, HAVE HIM MAKE ALL AS BUILT CHANGES.
08/28/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) THERE ARE FOUR SETS OF GANG BATHROOM NONE ARE COMPLETE AND ALL REQUIRE MULTIPLE CORRECTIONS 2.) KITCHEN IS NOT READY FOR INSPECTION 3.) NO DRINKING FOUNTAINS HAVE BEEN SETS.
08/27/2001 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) PLUMBING FINAL NOT READY 2.) REMEMBER, REQUIRE 6" FROM TOP OF URINAL OR WATER CLOSET TO CRITICAL LEVEL OF FLUSH O METER.
08/19/2001 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) PLUMBING FINAL NOT READY 2.) OK FOR TEMP POWER.
08/13/2001 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION 2.) ROUGH IN IS NOW COMPLETE.
08/02/2001 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION.