Permit: T01CM02566

Parcel: 137105120


Addresses:

5660 S 12TH AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM02566

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) INTERMEDIATE AT KITCHEN OK DWV OK WATER TEST TO 10' OK COOPER OK PRESSURE OK 2.) GREASE TRAP OK 3.) OK TO BACKFILL OK FOR SHEETROCK.
07/31/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
07/26/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) BATHROOMS BETWEEN "B" & D" FIRST AND SECOND FLOOR ABS DWV BOTH FLOORS OK WATER TEST 10' HEAD OK COPPER OK PRESSURE TEST OK 2.) OK FOR DRYWALL THIS AREA ONLY 3.) NEED TO SEE VTRS.
07/18/2001 PLUMBING - INTERMEDIATE Partial Approval 1.) INTERMEDIATE AT OFFICE OK ALL CORRECTIONS MADE OK IN THIS AREA OK TO COVER CLOSET RING OK.
07/16/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) INTERMEDIATE AT OFFICE NOT READY WATER TEST TO 10' RUN VENT THRU ROOF CLOSET RING. REMOVE TIE-WIRE.
07/12/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*1.) NOT READY FOR INSPECTOR 2.) PLEASE READ THIS NOT CAREFULLY. BENT NAIL AND TIE-WIRE ARE NOT APPROVED STRAPS DO NOT USE THEM ON THIS OR ANY OTHER JOB.
07/05/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) ABS REQUIRES MINIMUN 12" OF COVER 2.) INTERMEDIATE NOT READY NOTE: I DONT KNOW WHO IS INSTALLING THE PLUMBING BUT THE CONTRACTOR WHO HOLDS THE PLUMBING LICENSSE IS RESPONSIBLE FOR THE INSTALLATION. I KNOW THE PLUMBING CONTRACTOR AND I FEEL HE WOULD NEVER INSTALL PLUMBING OF THIS NATURE HAVE JERRY CALL ME AT 909-5157
07/02/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
06/27/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) OK TO COVER ROUGH IN AT OFFICE 2.) OK TO SHEET ROCK CLASSROOMS 1ST & 2ND FLOOR EASTSIDE 3.) ROUGH IN FOR BATHROOMS BETWEEN BLDG "B" & D (REVISED) OK WATER TEST RISER ONLY.4.) FIRST FLOOR BLDG "B" OK 2ND FLOOR BLDG "B" OK FOR DRYWALL.
06/26/2001 PLUMBING - INTERMEDIATE Denied 1. 2ND FLOOR ABS DRAIN BACKPITCHED 2.) COPPER NOT SUPPORT IN WALL 3.) TIE WIRE NOT AN APPROVED STRAP SEE NOT O6 ZI OL 4.) BLDG "B" OK FOR DRYWALLS ONLY.
06/25/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION
06/21/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1)ABS DWV WATER TEST INCOMPLETE.WATER TEST ALL FITTINGS ADDED SINCE UNDERGROUND TEST.2)ABS NOT SUPPORTED IN THE WALL.3)COPPER NOT SUPPORTED IN WALLS.
4)BENT NAILS NOT APPROVED STRAP.5)TIE-WIRE NOT APPROVED STRAP.