Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
7275 S TUCSON BL
Apply Date:
03/06/2000
Applicant:
GRESHAM & BEACH ARCHITECTS
Description:
CAR RENTAL/OFFICE: ORIGINAL EFFECTIVE DATE 8-9-02
Contractors:
  • TARGET GENERAL INC ,

Permit Reviews

Permit Number - T00CM01082
Permit Status: C of o
Permit Description: CAR RENTAL/OFFICE: ORIGINAL EFFECTIVE DATE 8-9-02
Start Date Submittal Complete Date Status  
01/18/2002 REVISION 02/15/2002 COMPLETED Review Details
02/21/2001 REVISION 03/09/2001 COMPLETED Review Details
05/18/2001 REVISION 05/18/2001 COMPLETED Review Details
08/23/2000 3RD PARTY REVIEW-COMMERCIAL 01/31/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T00CM01082
Permit Description: CAR RENTAL/OFFICE: ORIGINAL EFFECTIVE DATE 8-9-02
Total Completed Inspections - 35
Date Description Inspector Results Comments
11/21/2000 EXCAVATION/LAYOUT REBAR & ZON DWITT Approved
11/29/2000 STEM WALL/RETAINING WALL DWITT Approved IVRS - Inspection 0000*
12/12/2000 REINFORCED MASONRY PRE-GROUT DWITT Approved IVRS - Inspection 0000*
08/20/2001 ELECTRIC - UNDERGROUND JORTA Approved IVRS - Inspection 0000*ROOM 103, 104, AND 105 APPROVED. TELEPHONE AND POWER UNDERGROUND COMPLETE ON WEST SIDE.
09/04/2001 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*NO OTHER INSPECTIONS CALLED CONTACTOR IS CALLING FOR TEMP POWER FOR TESTING. TEMP POWER OK PENDING APPROVAL BY OTHER INSPECTORS.
09/11/2001 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection 0000*CANCELED AIRPORT CLOSED.
09/19/2001 ELECTRIC - TEMPORARY POLE JORTA Approved IVRS - Inspection 0000*TEMP POWER FOR CONSTRUCTION USE SP1 TO TRANSFORM TO DP-1 TO EXTERIOR TEMP SUB PANEL AND RECEPTACLE
09/21/2001 BOILER ROUGH RLOHRMAN Approved IVRS - Inspection 0000*OK CALL 602-542-1648 FOR OPERATING CERTIFICAL.
09/30/2001 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*1.) PLUMBING YARD WATER LINE/TEST 1.) 2"PVC YARDWATER OK PRESSURE TEST OK 2.) OK TO BACKFILL 3.) NEED TO SEE FINAL PIPING AND CONNECTIONS TO METER.
10/01/2001 PLUMBING - FINAL RMYERS Approved 1.) THE WORK ON THIS PERMIT GOES BEYOND A SIMPLE RE-PIPE.YOU HAVE REMOVED FIXTURES TO BE REPLACED AFTER YOU HAVE REMODELED THE BATHROOM.YOU WILL NEED PERMITS TO COVER ALL THE WORK PERFORMED.
10/15/2001 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*1.) WATER AND OIL SEPARATOR IN CARPET CLEANING ROOM INSTALLED OK UNDERGROUND INSTALL CLEAN-OUTS ON INTERMEDIATE. 2.) OK TO COVER 3.) THIS COMPLETES THE UNDERGROUND PORTION OF THIS CONTRACT.
10/31/2001 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*PARTIAL @ TENANT SPACES WALLS APPROVED. XCEPT @ PANEL BOARDS. INSTALLED BELOW FOREIGN PIPING DUCTING ETC. SEE 110-26 99 NEC.
11/15/2001 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*1.) PLUMBING INTERMEDIATE OK N/H DWV OK PRESSURE TEST OK ON COPPER OK TO COVER WALL. 2.) WHERE ROOF DRAIN COMBINES WITH OVERFLOW I QUESTION 1 4" ROOF DRAIN AND OVERFLOW DUMPING INTO 3" PIPE OBSTRUCTION FO FLOW 2.) NO SQ FOOTAGE OF DRAINAGE TO VERIFY SIZING. IS PIPE OVERSIZED TO ALLOW COMBINING? 3.) PROVIDE COMPLETE DATA SUPPORTING INSTALLATION.
11/15/2001 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*SW AND PART OF SE. ALL EDGES REQUIRE SECREWS TO BE MINIMUM 3/8" FROM EDGE.
12/04/2001 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*CHECKED HIGH PRESS DUCTS TO VAV'S BEGINNING LOW PRESS DUCTS TO LINERS PROGRESSING.
12/06/2001 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
12/17/2001 FRAMING LHANLY Approved IVRS - Inspection 0000*GRIO LINE 1.8 BARREL SOFFITS ALONG NORTH WALL; STONE.
12/28/2001 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection 0000*1.) THIS INSPECTION CONCERNS THE COMBINING OF ROOF DRAIN AND OVERFLOW DRAIN FOR THE CANOPY BETWEEN GRID LINES G.H 1.5 AND 8. UNDER THE CODE ENFORCED AT THE TIME THE PLANS WERE APPROVED, THESE DRAINS COULD BE COMBINED IF Z PIPE SIZED LARGER THAN REQ'D SIZE HNTB ARCHETECTS ENGINEERS SUBMITTED PAPER WORK. APPROVING THIS INSTALLATION. 2.) OK TO COVER.
12/28/2001 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection 0000*CENTER BARREL OK LID OVER DRIVEWAY NEEDS SOME VERTICAL.
01/08/2002 ELECTRIC - ABOVE CEILING JORTA Approved IVRS - Inspection 0000*NORTH/SOUTH SOFFIT. INTERMEDIATE SOFFIT AND BARREL SOFFIT. APPROVED.
05/08/2002 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*
05/08/2002 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*
05/08/2002 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection 0000*
05/19/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*1.) CONTRACTOR DESIRES GAS METER. ALL GAS PIPING COMPLETE. MEDIUM PRESSURE REGULATOR INSTALLED OK 2.) CONNECTIONS, VENTS AND VALVES ON ROUGH PIPING OK 3.) EQUIPMENT SUPPLIED REGULATOR NEED VENTING 4.) AFTER BOND POSTED, AND WITL S.LONGS APPROVAL OK FOR GAS METER.
05/20/2002 BOILER FINAL RMYERS Approved 1.) APPROVED BY OTHERS.
07/02/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
07/18/2002 SIGN - FINAL JYBARRA Approved
07/18/2002 FIRE - FINAL LTHOMAS Approved
08/09/2002 PERMIT FINALED LHANLY Approved
08/09/2002 BOILER UNFIRED PRESSURE VESSEL RMYERS Approved
08/09/2002 FIRE SPKLR - FINAL LTHOMAS Approved
08/09/2002 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
08/09/2002 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
08/09/2002 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
08/09/2002 BUILDING PRE-SLAB LHANLY Approved

Documents

File Name Document Type  
None CONSTRPLANS VIEW
C OF O_09-09-2002.TIF CERT OF OCC VIEW
C OF O_08-09-2002.TIF CERT OF OCC VIEW