Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T00CM01082
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2002 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
04/11/2002 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection 0000* | |
03/19/2002 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection 0000*LIGHT POLE BASES OK TO POUR. | |
03/18/2002 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999* LIGHT POLE BASES DENIED. 1.) CLEAN LOOSE DEBRIS FROM BOTTOM OF CAISSONS 2.) 3" CLEARANCE REQUIRED FROM SIDE OF BORE TO REBAR. 3. TOP RING OF REBAR CAGE SHOULD BE 2" FROM TOP OF FORM. | |
02/12/2002 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | MET WITH CONTRACTORS REP. TO DISCUSS HOW TO COMENSATE ON UNEVEN STAIR LANDINGS | |
09/05/2001 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection 0000*SMALL SLAB CENTER OF BREEZWAY. 2.) C6 RFI REPAIR DONE. | |
03/28/2001 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1.) INSTALLED ROUGH PLUMBING FOR RECESSED EWC AT VENDING L104. 2.) N/H UNDERGROUND AND TIED IN OK WATER TEST OK 3.) OK TO BACKFILL. | |
11/21/2000 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval |