Permit Details

Status:
Inspections
Type:
Development Package
Apply Date:
11/20/2024
Applicant:
Andie Hemmah
Description:
PRIVATE GRADING & DRAINAGE PLAN for LA ESCALERA PHASE 4, LOTS 1-215 related to TD-DEV-0224-00061

Permit Reviews

Permit Number - TD-DEV-1124-00312
Permit Status: Inspections
Permit Description: PRIVATE GRADING & DRAINAGE PLAN for LA ESCALERA PHASE 4, LOTS 1-215 related to TD-DEV-0224-00061
Start Date Submittal Complete Date Status  
01/24/2025 DEVELOPMENT PACKAGE NEW v.2 02/10/2025 APPROVED Review Details
09/16/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/22/2025 APPROVED Review Details
11/27/2024 DEVELOPMENT PACKAGE NEW v.1 01/21/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-1124-00312
Permit Status: Inspections
Permit Description: PRIVATE GRADING & DRAINAGE PLAN for LA ESCALERA PHASE 4, LOTS 1-215 related to TD-DEV-0224-00061
Total Outstanding Activity Conditions - 3
Date Name
01/09/2025 Wall permits must be on file before the DP can be closed.
12/12/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
12/12/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TD-DEV-1124-00312
Permite Description: PRIVATE GRADING & DRAINAGE PLAN for LA ESCALERA PHASE 4, LOTS 1-215 related to TD-DEV-0224-00061
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
05/13/2025 NPPO Monitoring N/A Complete (Recurring) See checklist items for details.

6/25/25
Temporary irrigation system has been installed in Nursery.
06/24/2025 N/A Partial Pass All graded areas shall have a compaction minimum of 95%,
except for bottom of Storm Water Basins. These should not be compacted.
09/19/2025 SITE - Stormwater Follow-up N/A Failed 9/19/25
1. The track out at Lalas Way needs to be repaired to function as in intended currently there is a bypass with no rock on it.
2. The trench berm is not continuous on east side of site. It is interrupted approximately at lot 142 and there is another interruption north of that area. There is another area at Lot 15 on West side where there is no BMP. The SWPPP has continuous BMP’s around Perimeter.
3. The grade Limit T Posts and rope have been knocked over at the NE of site, just west of the Storm Basin. These need to be repaired.
4. On plan it shows OP outlet protection at low point at perimeter at SE end of Site. There is just Trench Berm at this point.
5. inspection Reports need to be kept in SWPPP book.
11/03/2025 N/A Partial Pass 11/3/25
4-24" RCP (CL II) Drain Pipe. Coming from ROW Catch Basin. Approximately 20' of the RCP is outside ROW running .08% downgrade to Basin N1. Pipes layed out by survey and inverts elevations correct. Pipes bedded in bedding sand. Shaded with bedding sand and AB over shading. When I arrived AB was being compacted with Whacker. I was provided pictures of bedding and shading being compacted with whacker. Second pipe from last to the north, segment furthest east did not have correct downslope (.08%) Contracter corrected this. Contractor notified of need to schedule inspections for drain pipe/structures on the DP outside of ROW for the duration of the project.
10/30/2025 N/A Failed 10/30/25
East side of Subdivision. Footer Rebar layout is not to plan for Partial View Fence. Columns are only being built at the property lines of each lot. Plan calls for them at 136" on center.

Completed Inspections

Permit Status: Inspections
Permit Number: TD-DEV-1124-00312
Permit Description: PRIVATE GRADING & DRAINAGE PLAN for LA ESCALERA PHASE 4, LOTS 1-215 related to TD-DEV-0224-00061
Total Completed Inspections - 3
Date Description Inspector Results Comments
05/02/2025 NPPO Pre-Construction Passed 5/2/25 TOS Accounted for. Nursery ok. Ok To start grubbing. Do not disturb plants with orange tape.
See checklist items for details.
05/01/2025 PDSD Engineering Division Pre-Construction SITE Passed
06/27/2025 SITE - Stormwater Setup and Controls Passed When grading is not active soil stabilizers per the swppp plan will be used.
All Inlets at curb along Gran Escalera need to be gravel bagged correctly per plan.

The Swppp with AMH expires 6/30/25
I have verified the new Swppp agreement with KB Homes as the Owner/Developer of the new plan and CMG as having 3rd party operational control…It is Signed and looks correct.

New signed Plan will be uploaded today 6/27/25

See checklist items for details.

Documents

File Name Document Type  
APPROVED TD-DEV-0224-00061_V1.PDF DOCUMENTS VIEW
APPROVED TD-DEV-0224-00061_V2.PDF DOCUMENTS VIEW
SUB 1-SWPPP BINDER_V1.PDF DOCUMENTS VIEW
SUB 2-SWPPP BINDER_V2.PDF DOCUMENTS VIEW
SUB1-ESCALERA PH4 GRADING PLAN-SWPPP 11-19-24_V1.PDF DOCUMENTS VIEW
SUB2-ESCALERA PH4 COMMENT RESPONSE LETTER_V1.PDF DOCUMENTS VIEW