Permit: TD-DEV-0425-00097
Permit Details
Status:
Inspections
Type:
Development Package
Address:
8825 E TANQUE VERDE RD
Address NEW:
8825 E TANQUE VERDE RD
Apply Date:
04/03/2025
Applicant:
Andrew Diller
Description:
Development package for a new carwash. Zoning amendment TP-AMD-0124-0001.
Permit Reviews
Permit Number - TD-DEV-0425-00097
Permit Status: Inspections
Permit Description: Development package for a new carwash. Zoning amendment TP-AMD-0124-0001.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/08/2025 | DEVELOPMENT PACKAGE NEW v.5 | 10/16/2025 | REQUIRES RESUBMIT |
| 06/23/2025 | DEVELOPMENT PACKAGE NEW v.4 | 07/21/2025 | REQUIRES RESUBMIT |
| 11/06/2025 | DEVELOPMENT PACKAGE NEW v.6 | 11/12/2025 | REQUIRES RESUBMIT |
| 04/07/2025 | DEVELOPMENT PACKAGE NEW v.1 | 04/11/2025 | REQUIRES RESUBMIT |
| 04/21/2025 | DEVELOPMENT PACKAGE NEW v.2 | 05/28/2025 | REQUIRES RESUBMIT |
| 11/14/2025 | DEVELOPMENT PACKAGE NEW v.7 | 11/19/2025 | APPROVED |
| 06/18/2025 | DEVELOPMENT PACKAGE NEW v.3 | 06/18/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TD-DEV-0425-00097
Permit Status: Inspections
Permit Description: Development package for a new carwash. Zoning amendment TP-AMD-0124-0001.
| Date | Description | Comments |
|---|---|---|
| 11/14/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 11/14/2025 | Dust Control/Air Quality Permit is Required. (Utilized with DP's & TP's) |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TD-DEV-0425-00097
Permite Description: Development package for a new carwash. Zoning amendment TP-AMD-0124-0001.
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2026 | ENGR Grading Final | N/A | Not Ready | Call in a paving inspection for 10/14 to inspect reinforcement for next PCCP pour. |
| 10/27/2026 | Consultation SITE | N/A | Partial Pass | Discussed construction sequences and requirements. |
| 10/27/2026 | N/A | Partial Pass | checked ramp at south east - corrected from Saturday. | |
| 10/24/2026 | ENGR Paving | N/A | Partial Pass | 10/24/26 7" PCCP on east side of main parking areas south of building and 3 curb ramps- Trench drain is precast and differs from detail 13/C303. I was informed that the engineer approves of this and change will be included in As-Builts. Reinforcing is correct and expansion joint material are in place at cold joints. Okay to pour this area. -2 of the curb ramps with domes SW of trench drain are correct. The 3rd south of the crosswalk was over 8.33% but I will allow them to pour this ramp provided it is corrected and complies- this ramp is at risk. -Subgrade at main entrance at SW corner to the PCCP is correct. Okay to place AB here. Call in paving inspection prior to paving here for approval of ABC. |
| 10/23/2026 | Grading Progress ENGR | N/A | Partial Pass | Area of Heavy duty concrete on East side of building and west of asphalt. ABC needs to be adjusted 1" +/- at some of the curb reveals for a 6" curb and 7" of Concrete pavement. Use plate tamper when adjusting the reveals and to tamp any loose areas. Ensure depth of concrete will reach 7" . ABC and subgrade density complies. Submit results to the portal. When ABC depth corrected okay to place #3 rebar @ 18” OC each way, with dobies/chairs for correct clearance over the AB. Subgrade for Asphalt still need work to be complete and ready for AB |
Completed Inspections
Permit Status: Inspections
Permit Number: TD-DEV-0425-00097
Permit Description: Development package for a new carwash. Zoning amendment TP-AMD-0124-0001.
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2026 | NPPO Pre-Construction | Passed | 1. NPPO - 3 transplants to be moved one time into the scenic corridor for required revegetation of that area. 2. Established NPPO nursery location and water source for temporary irrigation. 3. Construction trailer to be placed on site within the scenic corridor where plants have died or are non existent. |
|
| 04/28/2026 | PDSD Engineering Division Pre-Construction SITE | Passed | ||
| 05/15/2026 | SITE - Stormwater Setup and Controls | Passed | Trackout in place. Use large dia rock when refreshing trackout. Protect outlets to north with wattle and rough cut basin before monsoon season begins. | |
| 09/17/2026 | Passed | |||
| 10/23/2026 | For trash and recycling enclosures | Passed | ||
| 10/27/2026 | Passed |
Scheduled Inspections
Scheduled Inspections - TD-DEV-0425-00097
Status: Inspections
Description: Development package for a new carwash. Zoning amendment TP-AMD-0124-0001.
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 11/03/2026 | Grading Progress ENGR | Scheduled | |
| 11/03/2026 | ENGR Paving | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.