Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TD-DEV-0424-00140
Permit Details
Status:
In Revision
Type:
Development Package
Address:
1500 E TUCSON MARKETPLACE BL
Address NEW:
1500 E TUCSON MARKETPLACE BL
Apply Date:
04/29/2024
Applicant:
Alexis Neuroth
Description:
Rev 1 - EV units, parking log, sewer update, started 12.22.2025 ** Ground up development for new retail store.
Permit Reviews
Permit Number - TD-DEV-0424-00140
Permit Status: In revision
Permit Description: Rev 1 - EV units, parking log, sewer update, started 12.22.2025 ** Ground up development for new retail store.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/29/2024 | DEVELOPMENT PACKAGE NEW v.1 | 05/08/2024 | REQUIRES RESUBMIT |
| 09/10/2024 | DEVELOPMENT PACKAGE NEW v.4 | 10/10/2024 | REQUIRES RESUBMIT |
| 12/22/2025 | DEVELOPMENT PACKAGE NEW REVISION v.1 | 12/22/2025 | REQUIRES RESUBMIT |
| 01/09/2026 | DEVELOPMENT PACKAGE NEW REVISION v.2 | N/A | IN REVIEW |
| 11/26/2024 | DEVELOPMENT PACKAGE NEW v.5 | 12/03/2024 | APPROVED |
| 07/22/2024 | DEVELOPMENT PACKAGE NEW v.3 | 08/23/2024 | REQUIRES RESUBMIT |
| 05/15/2024 | DEVELOPMENT PACKAGE NEW v.2 | 06/27/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TD-DEV-0424-00140
Permit Status: In revision
Permit Description: Rev 1 - EV units, parking log, sewer update, started 12.22.2025 ** Ground up development for new retail store.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/12/2025 |
Outstanding Inspections
Permit Status: In Revision
Permit Number: TD-DEV-0424-00140
Permite Description: Rev 1 - EV units, parking log, sewer update, started 12.22.2025 ** Ground up development for new retail store.
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/10/2025 | ENGR - Drainage Structures | N/A | Partial Pass | Okay to button up forms on E2. call for inspection prior to pouring concrete. |
| 11/28/2025 | N/A | Partial Pass | Verified sleeves are in place. | |
| 12/11/2025 | N/A | Partial Pass | Contractor grading for curb in the west parking lot area islands 12 different islands contractor formed up all good they can pour concrete | |
| 10/10/2025 | For trash and recycling enclosures | N/A | Partial Pass | Will verify that verts are trimmed |
| 01/21/2026 | ENGR Paving | N/A | Partial Pass | Tucson asphalt is paving the west parking lot |
| 01/30/2026 | N/A | Partial Pass | Area I am inspecting today 12" HDPE at SW of Bldg. 2 legs of 12" Trench is dug correct from 90 deg elbows at building. Okay to bed this trench to 70' toward Catch Basin. At 70' 12 inch HDPE is in place and bedded correctly to the catch basin. Min 1 % slope correct. OK to backfill this stretch. Two more legs of 12 inch HDPE pipe to the building are not dug yet and will be soon. On the other side of Catch Basin there is 18 inch HDPE that extends out two sticks joined correctly and bedded correct. Min 1 % slope correct. Both joints at the catch basin have been inspected previously. OK to backfill this 40' 18" leg.. | |
| 01/30/2026 | Grading Progress ENGR | N/A | Partial Pass | 1/30/26 Subgrade inspection for outdoor showroom area. Rectangular area to east of building that all slopes toward catch basin midway at west side of area, just east of loading dock. This catch basin has not been installed yet. Density testing complies. Grade is even and sloped correctly into catch basin, hubs in place and good. OK to place AB for 3" over 4" light duty asphalt |
Completed Inspections
Permit Status: In Revision
Permit Number: TD-DEV-0424-00140
Permit Description: Rev 1 - EV units, parking log, sewer update, started 12.22.2025 ** Ground up development for new retail store.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PDSD Engineering Division Pre-Construction SITE | Passed | |||
| 09/22/2025 | SITE - Stormwater Setup and Controls | Passed | NOI Good. SWPPP inspections good up to last one on 9/4. Track out needs to be built per detail in plan. Also in the wrong location. Concrete washout in place but it needs to cleaned out. 75% full. Wattle Needs to cover SW corner of side up to the curb line of the Costco parking lot. |