Permit Details

Status:
Inspections
Type:
Development Package
Address:
4410 S PARK AV
Address NEW:
4410 S PARK AV
Apply Date:
04/02/2023
Applicant:
Don Perkins
Description:
Restricted Access - *Revision #1 (building sq ft.) started 5/6/24* Development package for City of Tucson Southside Public Safety Facility Police Substation and Fire Station NO. 10

Permit Reviews

Permit Number - TD-DEV-0423-00198
Permit Status: Inspections
Permit Description: Restricted Access - *Revision #1 (building sq ft.) started 5/6/24* Development package for City of Tucson Southside Public Safety Facility Police Substation and Fire Station NO. 10
Start Date Submittal Complete Date Status  
05/06/2024 DEVELOPMENT PACKAGE REVIEW v.1 05/13/2024 REQUIRES RESUBMIT Review Details
04/03/2023 DEVELOPMENT PACKAGE REVIEW v.1 06/01/2023 REQUIRES RESUBMIT Review Details
06/03/2024 DEVELOPMENT PACKAGE REVIEW v.2 06/25/2024 REQUIRES RESUBMIT Review Details
08/09/2024 DEVELOPMENT PACKAGE REVIEW v.3 09/05/2024 APPROVED Review Details
12/04/2023 DEVELOPMENT PACKAGE NEW v.1 12/28/2023 REQUIRES RESUBMIT Review Details
01/04/2024 DEVELOPMENT PACKAGE NEW v.2 01/05/2024 APPROVED Review Details

Outstanding Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0423-00198
Permite Description: Restricted Access - *Revision #1 (building sq ft.) started 5/6/24* Development package for City of Tucson Southside Public Safety Facility Police Substation and Fire Station NO. 10
Total Outstanding Inspections - 10
Last Inspection Date Description Inspector Results Comments
10/24/2024 PDSD Engineering Division Pre-Construction SITE N/A Canceled
11/07/2024 N/A Partial Pass Okay for grouting sleeves.
11/15/2024 For trash and recycling enclosures N/A Partial Pass Okay to pour footing & Bollards. Gate Posts will pour with slab & Apron
02/03/2026 LAND Landscape Appearance & Function Final N/A Partial Pass Contractor scarified the basin the north west corner. Looks good as of today. Contractor is going to wait until it raids to see if it perks or not before putting DG in.
10/09/2025 ENGR Paving N/A Partial Pass 10/9/25
Driveway area at South Entrance to parking lot onto Fair.
Plan Keynote 3 in Construction Notes- 8" PCCP states 6" ABC/Native compacted to 95%.
It then refers to detail 1 sheet 7. This Detail shows ABC compacted to 100%. Geotec Report states that structural fill underneath Concrete Pavement to be compacted to minimum 95%. RFI the Engineer for clarification on this Detail. ABC is testing at 97% in area of concrete placement. Forms are correct with dowels at joint. Thickness correct. Slope correct. Use expansion material to full thickness of concrete. Okay to pour this area pending weather.
09/18/2025 N/A Partial Pass 9/18/25
Curb forms defining the south side of driveway at north west corner of site. Curb opening, subgrade good. Trackout rock needs to be cleared out from north end of forms, once this area is correct OK to pour this curb.
Curb forms to the south of building. Forms and subgrade are good expansion material in place correctly. Layout correct to survey. These forms are not 100% finished but are Okay to pour based on prior record.

9/18/25
Curbs that has been poured on this site are within acceptable tolerances. Finish looks good, curb openings, and elevations are correct to plan.
These curbs include the majority of the curbing on site in this phase on the south side and west side of the building all the way over to the large retention basin on north side of building. There are a couple islands and other areas that are not yet poured/formed.

Opening in site wall needed for basin overflow noted on plans at corner 20 yards or so south of driveway at NE of site.
04/15/2026 N/A Not Ready Landscape area south of apparatus Drive area. Alternating swales and landscaping with headers in between. 2 foot root barriers are in place around trees correctly protecting the headers in this area. Trees planted correctly but not staked correctly to Tree staking detail on LL 2.1. If Trees can support themselves tree staking is not necessary. Otherwise follow this detail.
04/15/2026 ENGR - Drainage Structures N/A Partial Pass Inspecting the Planters- waterproofing, and weep hole drains.
Trico waterproofing product in place, and iso board is in place up to where continuous rock pocket will be placed. OK to finish planters.
04/20/2026 N/A Partial Pass contractor can go ahead and backfill the irrigation line at the corner of the property that runs south east corner and run from the south east corner to north they can backfill all the irrigation lane
03/12/2026 N/A Not Ready 3/12/26 Planters at Entry Area.
Detail 9 LH2.2 refers to detail in structural. Use this detail 85 or RFI from Engineer. Retaining wall that retain less than 3’ of dirt can use detail 13 Masonry site wall/footing detail, but all cells filled with grout with a bond beam at top at top course if retained earth. Current footer is dimensioned to this detail. but has verts every 8” OC and would be grouted solid. This is sufficient for walls retaining less than 3’ with a bond beam at top of retaining course.

Completed Inspections

Permit Status: Inspections
Permit Number: TD-DEV-0423-00198
Permit Description: Restricted Access - *Revision #1 (building sq ft.) started 5/6/24* Development package for City of Tucson Southside Public Safety Facility Police Substation and Fire Station NO. 10
Total Completed Inspections - 1
Date Description Inspector Results Comments
11/04/2024 PDSD Engineering Division Pre-Construction SITE Passed

Documents

File Name Document Type  
DEVELOPMENT BIND 05032024_V1.PDF DOCUMENTS VIEW
APPROVED_DEVELOPMENT BIND 010324_V3_V1.PDF DOCUMENTS VIEW
COT_PUBLIC_SAFETY_CIVIL PLANS_V1.PDF DOCUMENTS VIEW
DEVELOPMENT BIND 05032024_V1.PDF DOCUMENTS VIEW
PERLMAN_RESPONSE LETTER_DEVELOPMENT_V1.PDF DOCUMENTS VIEW
COT_PUBLIC_SAFETY_CIVIL PLANS_V1.PDF DOCUMENTS VIEW
DEVELOPMENT BIND 05032024_V1.PDF DOCUMENTS VIEW
COT_PUBLIC_SAFETY_CIVIL PLANS_V1.PDF DOCUMENTS VIEW
DEVELOPMENT BIND 05032024_V1.PDF DOCUMENTS VIEW
PERLMAN_RESPONSE LETTER_DEVELOPMENT_V1.PDF DOCUMENTS VIEW
DEVELOPMENT BIND 05032024_V1.PDF DOCUMENTS VIEW
COT_PUBLIC_SAFETY_CIVIL PLANS_V1.PDF DOCUMENTS VIEW
DEVELOPMENT BIND 05032024_V1.PDF DOCUMENTS VIEW
PERLMAN_RESPONSE LETTER_DEVELOPMENT_V1.PDF DOCUMENTS VIEW