Permit Reviews

Permit Number - TC-MDP-0724-00847
Permit Status: Complete
Permit Description: SFR Model Plan (Model master plan TC-MDP-0424-00532)
Start Date Submittal Complete Date Status  
12/17/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 01/07/2025 REQUIRES RESUBMIT Review Details
06/23/2025 RESTAMP - RESIDENTIAL v.1 06/23/2025 APPROVED Review Details
08/01/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 08/20/2024 REQUIRES RESUBMIT Review Details
09/25/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 10/08/2024 REQUIRES RESUBMIT Review Details
02/11/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4 02/25/2025 REQUIRES RESUBMIT Review Details
04/08/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/08/2026 APPROVED Review Details
09/15/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/15/2025 APPROVED Review Details
06/06/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.5 06/23/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0724-00847
Permit Status: Complete
Permit Description: SFR Model Plan (Model master plan TC-MDP-0424-00532)
Date Description Comments
02/11/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
07/29/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/29/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/16/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0724-00847
Permite Description: SFR Model Plan (Model master plan TC-MDP-0424-00532)
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
08/25/2025 COT - RSBU - Preslab N/A Re-inspection required 8-25-25: missing ufer, add chairs to all diagonal #4's, clean footings of excess debris/loose dirt, and compact section of pad along the northwestern portion of home.
09/26/2025 COT - RSBU - Interior Shear Bracing N/A Canceled 9-26-25: schedule this inspection when you have drywall installed to verify nailing.
03/06/2026 COT - RSEL - Electrical Final N/A Re-inspection required 3/6/2026
Outlet in laundry needs to be GFCI, water heater in garage needs disconnect wired, add address number at front building visible from street - minimum 4" in height. Paint plastic pipes outside, cut cleanout flush to grade in front, secure AC condensate line on roof with redwood block and secure electrical whip.
03/06/2026 COT - RSME - Mechanical Final N/A Re-inspection required 3/6/2026
Outlet in laundry needs to be GFCI, water heater in garage needs disconnect wired, add address number at front building visible from street - minimum 4" in height. Paint plastic pipes outside, cut cleanout flush to grade in front, secure AC condensate line on roof with redwood block and secure electrical whip.
03/06/2026 COT - RSPL - Plumbing Final N/A Re-inspection required 3/6/2026
Outlet in laundry needs to be GFCI, water heater in garage needs disconnect wired, add address number at front building visible from street - minimum 4" in height. Paint plastic pipes outside, cut cleanout flush to grade in front, secure AC condensate line on roof with redwood block and secure electrical whip.
03/06/2026 RSBU - Building Final N/A Re-inspection required 3/6/2026
Outlet in laundry needs to be GFCI, water heater in garage needs disconnect wired, add address number at front building visible from street - minimum 4" in height. Paint plastic pipes outside, cut cleanout flush to grade in front, secure AC condensate line on roof with redwood block and secure electrical whip.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0724-00847
Permit Description: SFR Model Plan (Model master plan TC-MDP-0424-00532)
Total Completed Inspections - 19
Date Description Inspector Results Comments
08/11/2025 COT - RSPL - Backwater Valve Passed 8.11.25
Approved
08/11/2025 COT - RSPL - Sewer Passed 8.11.25
Approved
08/11/2025 COT - RSPL - Rough Soil Passed 8.11.25
Approved
08/15/2025 COT - RSPL - Yard Water Line Passed
08/27/2025 COT - RSBU - Preslab Passed 8.27.2025
Corrections made from 8.25.2025 inspection, okay to proceed.
08/27/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 8.27.2025
Corrections made from 8.25.2025 inspection, okay to proceed.
09/26/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9-26-25: exterior clips/sheathing & framing approved. Okay to continue with construction.
09/26/2025 COT - RSBU - Roof Nailing Passed 9-26-25: okay to dry in roof.
11/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 11.03.2025
Approved. Added nail plate to oven vent at top plate, lowered thermostat to 48", fire foamed penetration.
11/03/2025 COT - RSEL - Grounding/Bonding Passed
11/10/2025 COT - RSBU - Interior Shear Bracing Passed 11/10/2025 approved.
12/16/2025 COT - RSEL - Electrical Underground Passed 12/16/2025
Approved. Schedule 40 conduit trenched to transformer with a 20ft run - okay to backfill with shading materials.
12/16/2025 BULD - Electrical Clearance Passed 12/16/2025
Clearance to TEP ECO.
03/06/2026 ENGR Engineering Final Passed
03/06/2026 COT - RSEL - Outdoor Lighting Passed
03/11/2026 COT - RSEL - Electrical Final Passed 03/11/2026
Corrections made to prior insertion.
03/11/2026 COT - RSME - Mechanical Final Passed 03/11/2026
Corrections made to prior insertion.
03/11/2026 COT - RSPL - Plumbing Final Passed 03/11/2026
Corrections made to prior insertion.
03/11/2026 RSBU - Building Final Passed 03/11/2026
Corrections made to prior inspection.

Documents

File Name Document Type  
2_MJCS_V2 (1)_V1.PDF DOCUMENTS VIEW
COFO_FINALCOFO_RESIDENTIAL (SSRS).PDF DOCUMENTS VIEW
MIDVALETRUSSES_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
5563 S SWIRES RD SITE.REV.2 (1)_V4.PDF DOCUMENTS VIEW
DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO NOTICE AND MAP.PDF SPECIAL APPLICATIONS VIEW
DDO APPLICATION AND PLANS.PDF SPECIAL APPLICATIONS VIEW