| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2024 | Residential Building | APPROVED | |||
| 10/08/2024 | Site Engineering | APPROVED | |||
| 10/08/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/07/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-MDP-0724-00847 5563 S SWIRES RD. – R-2 New SFR (2nd Review) TRANSMITTAL DATE: October 7, 2024 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 16’-6” the required perimeter yard setback to the north and south property line is 11’-0”, proposed setback to the north property line is 7’-0”, and the proposed setback to the south property line is 7’-1”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 09/25/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 09/25/2024 | ROW Engineering Review | REVIEW COMPLETED | ROW permit required prior to working in the ROW |