Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Apply Date:
08/16/2024
Applicant:
Stephanie Bebee
Description:
PV 1520 SFR

Permit Reviews

Permit Number - TC-MDP-0724-00790
Permit Status: Inspections
Permit Description: PV 1520 SFR
Start Date Submittal Complete Date Status  
08/22/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 08/22/2024 REQUIRES RESUBMIT Review Details
09/20/2024 SITE FROM MODEL PERMIT - PRODUCTION v.2 09/24/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0724-00790
Permit Status: Inspections
Permit Description: PV 1520 SFR
Total Outstanding Activity Conditions - 4
Date Name
07/12/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
09/24/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
09/24/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/24/2024 Post-Tension Inspection Report is required.

Conditions

Permit Number - TC-MDP-0724-00790
Permit Status: Inspections
Permit Description: PV 1520 SFR
Date Description Comments
07/12/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
09/24/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0724-00790
Permite Description: PV 1520 SFR
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
11/21/2024 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required Provide address tag. 11/20/2024
11/21/24: Anchor bolt spacing not per plan, anchor bolts required at interior bearing walls, anchor bolts required 12" from edge of sill plate, anchor bolts must be located in middle third of width of plate. RSP4 required on north wall, H2.5 must be properly fastened, CS16 straps at garage must be 54" in length currently 48", LSTHD 8 required at back patio entrance. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
11/21/2024 COT - RSBU - Roof Nailing N/A Re-inspection required Provide address tag. 11/20/2024
11/21/24: Anchor bolt spacing not per plan, anchor bolts required at interior bearing walls, anchor bolts required 12" from edge of sill plate, anchor bolts must be located in middle third of width of plate. RSP4 required on north wall, H2.5 must be properly fastened, CS16 straps at garage must be 54" in length currently 48", LSTHD 8 required at back patio entrance, nailing at shearwall not per schedule. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0724-00790
Permit Description: PV 1520 SFR
Total Completed Inspections - 7
Date Description Inspector Results Comments
10/21/2024 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 10/21/2024
10/21/2024 COT - RSPL - Sewer Passed
10/21/2024 COT - RSPL - Rough Soil Passed Okay to backfill. Shading required. 10/21/2024
10/25/2024 COT - RSEL - Electrical Underground Passed
10/25/2024 COT - RSEL - Grounding/Bonding Passed
10/28/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Corrections made 10/28/24
10/28/2024 COT - RSBU - Preslab Passed Corrections made 10/28/24

Documents

File Name Document Type  