Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Permit Number - TC-MDP-0724-00790

Inspection Description - RSBU - Building Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/23/2025 RSBU - Building Final  Re-inspection required Provide ladder for roof access. Provide traffic rated covers for sewer lines in driveway. Gfci receptacle left side of garage defective and is tied into water heater receptacle. Water circulating pump wires exposed. Missing hammer arrestor on hot line for dishwasher. Provide high water loop on dishwasher hose. Provide cover plates at receptacle kitchen island. Provide a set of approved plans prior to final. Stopped inspection was. Other items may apply. 5/23/2025
06/10/2025 RSBU - Building Final  Re-inspection required Provide ladder for roof access. Provide traffic rated covers for sewer lines in driveway. Gfci receptacle left side of garage defective and is tied into water heater receptacle. Water circulating pump wires exposed. Missing hammer arrestor on hot line for dishwasher. Provide high water loop on dishwasher hose. Provide cover plates at receptacle kitchen island. Provide a set of approved plans prior to final. Stopped inspection was. Other items may apply. 5/23/2025
6/10/25: copper piping hot water line at garage water heater needs to be insulated, thermostat shall be no higher than 48" above finish floor, T-top at bathroom exhaust requires screen, T-top must be properly fastened at rain cover, knock-outs at RTU need to be sealed with approved covers, grounds at disconnect and RTU must be appropriately identified.
06/16/2025 RSBU - Building Final  Passed Approved. All corrections have been made. 6/16/2025