Permit: TC-MDP-0524-00637
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
1691 S SAN JOSE DR UNIT 1
Address NEW:
1691 S SAN JOSE DR UNIT 1
Apply Date:
06/18/2024
Applicant:
Description:
GC model 100 duplex
Permit Reviews
Permit Number - TC-MDP-0524-00637
Permit Status: Complete
Permit Description: GC model 100 duplex
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/20/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 07/02/2024 | REQUIRES RESUBMIT |
| 07/25/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 08/09/2024 | REQUIRES RESUBMIT |
| 06/20/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 06/20/2024 | REQUIRES RESUBMIT |
| 09/10/2024 | RESTAMP - RESIDENTIAL v.1 | 09/10/2024 | APPROVED |
| 08/22/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 09/10/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0524-00637
Permit Status: Complete
Permit Description: GC model 100 duplex
| Date | Description | Comments |
|---|---|---|
| 05/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 05/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 05/17/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0524-00637
Permite Description: GC model 100 duplex
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2025 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 08/04/2025 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 8-4-25: exterior receptacle covers underneath main panel must be bubble wrap type or remove altogether and cover using a knockout plug, insulate hot copper line at water heaters with a minimum of R3 insulation, cleanouts not tightened/secured, and exterior railing noncompliant. |
| 08/04/2025 | RSBU - Building Final | N/A | Re-inspection required | 8-4-25: exterior receptacle covers underneath main panel must be bubble wrap type or remove altogether and cover using a knockout plug, insulate hot copper line at water heaters with a minimum of R3 insulation, cleanouts not tightened/secured, and exterior railing noncompliant. |
| 08/04/2025 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | 8-4-25: exterior receptacle covers underneath main panel must be bubble wrap type or remove altogether and cover using a knockout plug, insulate hot copper line at water heaters with a minimum of R3 insulation, cleanouts not tightened/secured, and exterior railing noncompliant. |
| 08/04/2025 | COT - RSEL - Electrical Underground | N/A | Re-inspection required | 8-4-25: notes from 7-17-25 indicate not ready. Provide written documentation that underground electric was done per plans and meets the 2018 IRC requirements. Submit to the city for review and approval. |
| 08/04/2025 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 8-4-25: exterior receptacle covers underneath main panel must be bubble wrap type or remove altogether and cover using a knockout plug, insulate hot copper line at water heaters with a minimum of R3 insulation, cleanouts not tightened/secured, and exterior railing noncompliant. |
| 08/04/2025 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 8-4-25: exterior receptacle covers underneath main panel must be bubble wrap type or remove altogether and cover using a knockout plug, insulate hot copper line at water heaters with a minimum of R3 insulation, cleanouts not tightened/secured, and exterior railing noncompliant. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0524-00637
Permit Description: GC model 100 duplex
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2024 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 10/28/2024 | |
| 12/20/2024 | COT - RSBU - Preslab | Passed | 12/20/24 corrections have been made, ok to proceed. | |
| 01/02/2025 | COT - RSBU - Preslab and floodplain | Passed | 1/02/25 Completed by Tom. |
|
| 01/02/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 01/07/2025 | COT - RSBU - Roof Nailing | Passed | 1-7-25, roof nailing approved. Okay to continue with construction. | |
| 01/07/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 1-7-25, exterior clips/sheathing approved. Okay to continue with construction. | |
| 01/14/2025 | COT - RSPL - Yard Water Line | Passed | 1/14/25 pass, ok to backfill shading required. | |
| 01/14/2025 | COT - RSPL - Sewer | Passed | 1/14/25 pass, ok to backfill shading required. | |
| 01/14/2025 | COT - RSPL - Backwater Valve | Passed | 1/14/25 pass, ok to backfill shading required. | |
| 02/25/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Passed 2/25/25 ok to drywall | |
| 03/10/2025 | COT - RSBU - Interior Shear Bracing | Passed | Sheetrock nailing: Ok to tape and texture throughout. | |
| 04/17/2025 | BULD - Electrical Clearance | Passed | 4-17-25, okay to energize panel. ECO clearance issued to TEP. | |
| 07/17/2025 | COT - BULD - SWG Clearance | Passed | 7.17.25 All electric |
|
| 07/17/2025 | RSBU - Building Progress | Passed | ||
| 08/04/2025 | COT - RSEL - Grounding/Bonding | Passed | 8-4-25: approved | |
| 08/15/2025 | ENGR Engineering Final | Passed | All previous items have been corrected |