Permit Number: TC-MDP-0524-00637
Parcel: 118043870

Review Status: Requires Resubmit

Review Details: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2

Permit Number - TC-MDP-0524-00637
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2024 Residential Building APPROVED
08/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/09/2024 Site Engineering REQUIRES RESUBMIT 1. Due to the close proximity of the building to the floodplain, the proposed finished floor elevation of 6 inches above natural grade existing is not acceptable. The finished floor elevation shall be at least one foot above the highest natural existing grade within the proposed building footprint. Please provide a proposed finished floor elevation in feet NAVD88.

Mike Ortiz
michael.ortiz@tucsonaz.gov
08/05/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-MDP-0524-00637
1691 S SAN JOSE DR. – R-2
New Duplex (2nd Review)

TRANSMITTAL DATE: August 5, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-3 zone (UDC 4.7.9). A duplex is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

1. Zoning acknowledges that a revision to the model plan has been submitted but until the revision is approved by all review agencies Zoning cannot approve this permit. Based on the 12’-0” dimension provided on revised model plan TC-MDP-0224-00221 rear elevation the required perimeter yard setback from the proposed duplex to the north property line is 8’-0”, no actual proposed setback was provided”. A Design Development Option (DDO) may be required. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

2. Remove the “6’-0” S.B. dimension shown from the south property line and the associated setback line as they are not correct. The minimum side street perimeter yard setback is 10’-0”, UDC Article 6.4.5.C.1.b.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/25/2024 PDSD Application Completeness Express REVIEW COMPLETED
07/31/2024 ROW Engineering Review REVIEW COMPLETED Previous comments have been addressed, ROW permit required prior to working in the ROW.