Permit: TC-COM-0925-01709
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
2850 E DREXEL RD
Address NEW:
2850 E DREXEL RD
Apply Date:
09/19/2025
Applicant:
Andrew Venne
Description:
Tenant Improvment
Permit Reviews
Permit Number - TC-COM-0925-01709
Permit Status: Inspections
Permit Description: Tenant Improvment
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/19/2025 | COMMERCIAL REVIEW - FULL v.1 | 10/21/2025 | APPROVED |
| 10/21/2025 | ADMINISTRATIVE v.1 | 10/21/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-0925-01709
Permit Status: Inspections
Permit Description: Tenant Improvment
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 10/09/2025 | AIR BALANCING REPORT IS REQUIRED. |
| 10/09/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0925-01709
Permit Status: Inspections
Permit Description: Tenant Improvment
| Date | Description | Comments |
|---|---|---|
| 10/21/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 09/19/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0925-01709
Permite Description: Tenant Improvment
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2026 | COT - LCEL - Electrical Above Ceiling | N/A | Re-inspection required | 5-20-26: labeling junction at northeast section of office space areas, all electrical conduits must be individually supported and cannot be zip tied to existing wiring. The conduits must be supported by independent support wires, rods, or cables attached by the structural ceiling. See NEC 300.11 (B) for information. |
| 05/20/2026 | COT - LCME - Mechanical Intermediate | N/A | Re-inspection required | 5-20-26: add supports to flex where resting on ceiling grid-supports are required within 4' of registers, insulate all ducting, complete flex tie ins to registers, tape all tears at ducts/trunks- this is required to avoid condensation build up. |
| 03/24/2026 | COT - LCBU - Framing | N/A | Partial Pass | 3-24-26: interior wall framing along the north side of building (warehouse side) approved. Okay to insulate & install drywall at progress areas. (pending wall framing at doors). |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0925-01709
Permit Description: Tenant Improvment
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2026 | PDSD Building Division Pre-Construction Meeting | Passed | ||
| 02/25/2026 | COT - LCPL - Rough Soil | Passed | ||
| 03/25/2026 | COT - LCEL - Electrical Intermediate | Passed | 3-25-26: in wall electrical intermediates at warehouse & office areas approved. | |
| 05/05/2026 | COT - HCBU - Interior Shear Bracing | Passed | 5-5-26: all drywall screw inspections approved. | |
| 05/05/2026 | COT - HCPL - Plumbing Intermediate | Passed | 5-5-26: approved. |
Scheduled Inspections
Scheduled Inspections - TC-COM-0925-01709
Status: Inspections
Description: Tenant Improvment
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 05/21/2026 | COT - LCBU - Framing | Scheduled | |
| 05/21/2026 | COT - LCEL - Electrical Above Ceiling | Scheduled | |
| 05/21/2026 | COT - LCME - Mechanical Intermediate | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.