Permit: TC-COM-0624-01123
Permit Details
Status:
Needs Resubmittal
Type:
Commercial Building
Address:
1501 N ORACLE RD
Address NEW:
1501 N ORACLE RD
Apply Date:
06/11/2024
Applicant:
Description:
Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
Permit Reviews
Permit Number - TC-COM-0624-01123
Permit Status: Needs resubmittal
Permit Description: Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/07/2025 | ADMINISTRATIVE v.1 | 11/07/2025 | REQUIRES RESUBMIT |
| 01/28/2025 | COMMERCIAL REVIEW - FULL v.2 | 03/10/2025 | REQUIRES RESUBMIT |
| 05/06/2026 | SPECIAL INSPECTION REVIEW v.1 | 05/08/2026 | REQUIRES RESUBMIT |
| 06/06/2025 | COMMERCIAL REVIEW - FULL v.4 | 06/09/2025 | APPROVED |
| 06/09/2025 | RESTAMP - COMMERCIAL v.1 | 06/18/2025 | REQUIRES RESUBMIT |
| 06/18/2025 | RESTAMP - COMMERCIAL v.2 | 06/18/2025 | APPROVED |
| 10/16/2025 | HAST - COMMERCIAL NEW ADD/ALT FAST TRACK v.1 | 11/07/2025 | APPROVED |
| 04/30/2025 | COMMERCIAL REVIEW - FULL v.3 | 05/30/2025 | REQUIRES RESUBMIT |
| 11/18/2025 | ADMINISTRATIVE v.2 | 11/18/2025 | APPROVED |
| 02/05/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/12/2026 | REQUIRES RESUBMIT |
| 06/17/2024 | COMMERCIAL REVIEW - FULL v.1 | 07/26/2024 | REQUIRES RESUBMIT |
| 02/23/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 02/27/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0624-01123
Permit Status: Needs resubmittal
Permit Description: Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
Total Outstanding Activity Conditions - 20
| Date | Name |
|---|---|
| 05/07/2026 | Level __: (FRP) FIBER REINFORCE POLIMER PULL TEST THAT ARE ADHERED TO CONCRETE SURFACE. |
| 05/07/2026 | Level __: SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 05/07/2026 | Level __: Post-Installed Anchor Inspection Report is required. |
| 05/07/2026 | Level __: SPECIAL INSPECTION FOR REINFORCING STEEL IS REQUIRED. |
| 05/08/2025 | AIR BALANCING REPORT IS REQUIRED. |
| 05/08/2025 | ELEVATOR INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED. |
| 05/08/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 05/08/2025 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 05/08/2025 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 05/08/2025 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
| 05/08/2025 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
| 05/08/2025 | SPECIAL INSPECTION FOR Fire-Resistant Penetrations and Joints IS REQUIRED |
| 05/08/2025 | SPECIAL INSPECTION FOR SPRAY-APPLIED FIRE PROOFING IS REQUIRED. |
| 05/08/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
| 10/31/2025 | Masonry Inspection Report submittal review is required. |
| 10/31/2025 | Concrete floor repair and strengthening at roof (Level 17) lounge with calculations must be submitted and approved prior to installation of work. |
| 10/31/2025 | Concrete shear head strengthening with calculations must be submitted and approved prior to installation of work. |
| 10/31/2025 | Fiber Reinforced Polymer (FRP) Slab and Wall Strengthening with calculations must be submitted and approved prior to installation of work. |
| 10/31/2025 | SPECIAL INSPECTION FOR Column Shear Strengthening IS REQUIRED |
| 10/31/2025 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
Conditions
Permit Number - TC-COM-0624-01123
Permit Status: Needs resubmittal
Permit Description: Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
| Date | Description | Comments |
|---|---|---|
| 05/07/2026 | Level 16: (FRP) FIBER REINFORCE POLIMER PULL TEST THAT ARE ADHERED TO CONCRETE SURFACE. | |
| 06/17/2024 | Please contact Pima County Addressing to verify the official address. Addressing@pima.gov or 520-724-9512 | |
| 05/08/2025 | Level 16: SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 06/18/2025 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 06/18/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 05/08/2025 | Level 16: Post-Installed Anchor Inspection Report is required. | |
| 05/07/2026 | Level 16/17: SPECIAL INSPECTION FOR REINFORCING STEEL IS REQUIRED. | |
| 01/28/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 10/16/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 10/31/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. Special inspection certificate(s) need to be provided for masonry and column shear strengthening. |
Outstanding Inspections
Permit Status: Needs Resubmittal
Permit Number: TC-COM-0624-01123
Permite Description: Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
Total Outstanding Inspections - 16
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - FCON - Fire - Final | N/A | Not Ready | ||
| 06/18/2026 | COT - HCME - Venting | N/A | Not Ready | |
| 06/24/2026 | COT - HCEL - Electrical Above Ceiling | N/A | Not Ready | |
| 06/24/2026 | COT - HCME - Mechanical Above Ceiling | N/A | Not Ready | |
| 05/18/2026 | COT - HCPL - Rough Soil | N/A | Partial Pass | |
| 07/09/2026 | COT - HCEL - Electrical Underground | N/A | Partial Pass | |
| 07/09/2026 | COT - HCEL - Grounding/Bonding | N/A | Partial Pass | |
| 07/15/2026 | COT - HCPL - Gas Pressure Test | N/A | Not Applicable | |
| 07/22/2026 | COT - HCBU - Interior Shear Bracing | N/A | Partial Pass | 7/22/26: drywall nailing 15th floor approved @West and East corridors and units |
| 07/22/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | N/A | Partial Pass | 7/22/26:Screw pattern inspection 15 west corridor. 15 East wing |
| 07/08/2026 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | |
| 07/08/2026 | COT - HCBU - Framing | N/A | Partial Pass | |
| 07/08/2026 | COT - HCME - Mechanical Intermediate | N/A | Partial Pass | |
| 07/08/2026 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | |
| 07/24/2026 | BULD - Electrical Clearance | N/A | Re-inspection required | 7/24/26: Addresses tag required at meter base, torque sheet required at time of inspection, conduit duct seal required at raceway from exterior of building to interior of building, ensure lock out tag outs are all installed at SES. |
| COT - BULD - SWG Clearance | N/A | Scheduled |
Completed Inspections
Permit Status: Needs Resubmittal
Permit Number: TC-COM-0624-01123
Permit Description: Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/03/2026 | PDSD Building Division Pre-Construction Meeting | Passed | ||
| 07/09/2026 | COT - HCPL - Plumbing Above Ceiling | Passed |
Scheduled Inspections
Scheduled Inspections - TC-COM-0624-01123
Status: Needs Resubmittal
Description: Total renovation of 17 story Tucson House Building including replacement of mechanical and electrical systems and elevators. Complete update of parking and site areas.
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 07/27/2026 | COT - HCPL - Plumbing Intermediate | Scheduled | |
| 07/27/2026 | COT - BULD - SWG Clearance | Scheduled | |
| 07/27/2026 | BULD - Electrical Clearance | Scheduled |