Permit: TC-COM-0426-00560
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
3300 S PARK AV BLDG 3
Address NEW:
3300 S PARK AV BLDG 3
Apply Date:
04/15/2026
Applicant:
Brandon Willmon
Description:
New 2-story Building 3 on a vocational educational campus. Scope includes the building, parking lot, and connection between the second stories of existing Building 2 and new Building 3.
Permit Reviews
Permit Number - TC-COM-0426-00560
Permit Status: Inspections
Permit Description: New 2-story Building 3 on a vocational educational campus. Scope includes the building, parking lot, and connection between the second stories of existing Building 2 and new Building 3.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/04/2026 | COMMERCIAL REVIEW - FULL v.2 | 06/24/2026 | REQUIRES RESUBMIT |
| 07/08/2026 | ADMINISTRATIVE v.1 | 07/08/2026 | REQUIRES RESUBMIT |
| 04/20/2026 | COMMERCIAL REVIEW - FULL v.1 | 05/12/2026 | REQUIRES RESUBMIT |
| 06/30/2026 | COMMERCIAL REVIEW - FULL v.4 | 07/09/2026 | APPROVED |
| 06/26/2026 | COMMERCIAL REVIEW - FULL v.3 | 06/26/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-0426-00560
Permit Status: Inspections
Permit Description: New 2-story Building 3 on a vocational educational campus. Scope includes the building, parking lot, and connection between the second stories of existing Building 2 and new Building 3.
| Date | Description | Comments |
|---|---|---|
| 05/26/2026 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 04/20/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 04/20/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/20/2026 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0426-00560
Permite Description: New 2-story Building 3 on a vocational educational campus. Scope includes the building, parking lot, and connection between the second stories of existing Building 2 and new Building 3.
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/22/2026 | COT - HCEL - Grounding/Bonding | N/A | Partial Pass | 7/22/26: partial pass for UFER |
| 07/22/2026 | COT - HCPL - Sewer | N/A | Not Ready | 7/22/26: NOT READY. ADDED INSPECTION TO PERMIT CARD |
| 07/22/2026 | BULD - Electrical Clearance | N/A | Partial Pass | 7/22/26: partial pass for UFER |
| 07/31/2026 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | 7-31-26: verified 20 branch circuit Schedule 40 electrical conduits consisting of 3/4" & 1" for Panel L1D, L1B, L1C. Okay to backfill progress areas using shading materials. |
| 08/04/2026 | COT - HCBU - Preslab | N/A | Partial Pass | 8/4/2026 Partial pass. Elevator sump pit approved. Okay for concrete placement. |
| 08/06/2026 | COT - HCPL - Rough Soil | N/A | Partial Pass | 8/6/2026 Partial pass. In slab underground plumbing approved. Okay to backfill all progress areas. Shading required. |
| 07/24/2026 | COT - HCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 7-24-26: interior column footings at G/L: 7, 9, 10 verified per S1.1/Footing schedule F15, F12, F14, F8, F10 & Column Schedule C1, C2, C4, C1, C3. Okay for concrete placement. |
| COT - HCEL - Electrical Underground | N/A | Scheduled |
Scheduled Inspections
Scheduled Inspections - TC-COM-0426-00560
Status: Inspections
Description: New 2-story Building 3 on a vocational educational campus. Scope includes the building, parking lot, and connection between the second stories of existing Building 2 and new Building 3.
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 08/11/2026 | COT - HCEL - Electrical Underground | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.