Permit: TC-COM-0425-00783
Permit Details
Apply Date:
04/17/2025
Applicant:
George Zazueta
Description:
FIRE RESTORATION TO SFR - FIRE IN UPSTAIRS MASTER BEDROOM CLOSET- NEED TO DO ROOF REPAIR, 7 TRUSSES, ELECTRICAL, PLUMBING, HVAC, INSULATION AND DRYWALL
Permit Reviews
Permit Number - TC-COM-0425-00783
Permit Status: Issued
Permit Description: FIRE RESTORATION TO SFR - FIRE IN UPSTAIRS MASTER BEDROOM CLOSET- NEED TO DO ROOF REPAIR, 7 TRUSSES, ELECTRICAL, PLUMBING, HVAC, INSULATION AND DRYWALL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/03/2025 | ADMINISTRATIVE v.2 | 10/06/2025 | APPROVED |
| 10/03/2025 | RESTAMP - COMMERCIAL v.1 | 10/06/2025 | APPROVED |
| 04/23/2025 | COMMERCIAL REVIEW - FULL v.2 | 05/22/2025 | REQUIRES RESUBMIT |
| 06/17/2025 | COMMERCIAL REVIEW - FULL v.5 | 07/02/2025 | APPROVED |
| 08/14/2025 | COMMERCIAL REVIEW - FULL REVISION v.3 | 09/08/2025 | APPROVED |
| 05/30/2025 | COMMERCIAL REVIEW - FULL v.3 | 05/30/2025 | REQUIRES RESUBMIT |
| 04/22/2025 | COMMERCIAL REVIEW - FULL v.1 | 04/22/2025 | REQUIRES RESUBMIT |
| 08/11/2025 | COMMERCIAL REVIEW - FULL REVISION v.2 | 08/11/2025 | REQUIRES RESUBMIT |
| 06/16/2025 | COMMERCIAL REVIEW - FULL v.4 | 06/16/2025 | REQUIRES RESUBMIT |
| 10/03/2025 | ADMINISTRATIVE v.1 | 10/03/2025 | REQUIRES RESUBMIT |
| 12/17/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 12/22/2025 | APPROVED |
| 08/08/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 08/08/2025 | REQUIRES RESUBMIT |
| 07/02/2025 | RESTAMP - COMMERCIAL v.1 | 07/07/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0425-00783
Permit Status: Issued
Permit Description: FIRE RESTORATION TO SFR - FIRE IN UPSTAIRS MASTER BEDROOM CLOSET- NEED TO DO ROOF REPAIR, 7 TRUSSES, ELECTRICAL, PLUMBING, HVAC, INSULATION AND DRYWALL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/06/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0425-00783
Permit Status: Issued
Permit Description: FIRE RESTORATION TO SFR - FIRE IN UPSTAIRS MASTER BEDROOM CLOSET- NEED TO DO ROOF REPAIR, 7 TRUSSES, ELECTRICAL, PLUMBING, HVAC, INSULATION AND DRYWALL
| Date | Description | Comments |
|---|---|---|
| 05/14/2025 | AIR BALANCING REPORT IS REQUIRED. | |
| 07/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 07/03/2025 | THIS PERMIT IS A FIRE RESTORATION TO SINGLE FAMILY RESIDENCE-ANY OTHER USE WILL REQUIRE A TENANT IMPROVEMENT PERMIT | |
| 05/12/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0425-00783
Permite Description: FIRE RESTORATION TO SFR - FIRE IN UPSTAIRS MASTER BEDROOM CLOSET- NEED TO DO ROOF REPAIR, 7 TRUSSES, ELECTRICAL, PLUMBING, HVAC, INSULATION AND DRYWALL
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2025 | COT - FCON - Fire - Final | N/A | Not Applicable | |
| 12/24/2025 | COT - HCPL - Plumbing Intermediate | N/A | Re-inspection required (with fee) | 12-24-25: fire foam penetrations upstairs & from garage to living spaces-see previous notes, hot pex lines not secured, missing blocking at ends of shower-see detail 808/AD2 and flange detail for more, missing greywater-see previous notes. Stopped inspection-not ready. Note: framing inspection has been scheduled. |
| 02/18/2026 | COT - LCPL - Rough Soil | N/A | Not Applicable | |
| 02/18/2026 | COT - LCME - Mechanical Intermediate | N/A | Re-inspection required | 2/18/26: per previous inspection noted on 2-5-26 and 1/6/26 (flex duct shall be properly secured throughout), per inspection on 1/6/26 (B-vent shall maintain 1" clearance from combustibles at 2nd story), drain lines running horizontal between floors shall be properly secured every 4', properly secure walls at first floor closet bedroom and 2nd floor master bedroom, all penetrations at vapor barrier shall be sealed (2nd floor, marked with red marker). |
| 09/03/2026 | COT - LCPL - Plumbing Final | N/A | Re-inspection required | 9-3-26: missing anti-tip device and stove, missing dishwasher and hammer arrestor, missing hammer arrestor at refrigerator, missing receptacle cover/replace receptacle to weather resistant gfci at exterior wall adjacent to back sliding glass door, missing vacuum breaker at hose bib, a fire rated door from garage to home is required, threshold at garage does not meet ADA standards, missing receptacle covers at garage, pressure relief valve at water heater not connected, remove all debris from back yard. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. 2ND FLOOR NOT WALKED. |
| 09/03/2026 | COT - LCBU - Building Final | N/A | Re-inspection required | 9-3-26: missing anti-tip device and stove, missing dishwasher and hammer arrestor, missing hammer arrestor at refrigerator, missing receptacle cover/replace receptacle to weather resistant gfci at exterior wall adjacent to back sliding glass door, missing vacuum breaker at hose bib, a fire rated door from garage to home is required, threshold at garage does not meet ADA standards, missing receptacle covers at garage, pressure relief valve at water heater not connected, remove all debris from back yard. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. 2ND FLOOR NOT WALKED. |
| 07/21/2025 | COT - HCBU - TCO | N/A | Not Ready | 7-21-25: not ready for TCO. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0425-00783
Permit Description: FIRE RESTORATION TO SFR - FIRE IN UPSTAIRS MASTER BEDROOM CLOSET- NEED TO DO ROOF REPAIR, 7 TRUSSES, ELECTRICAL, PLUMBING, HVAC, INSULATION AND DRYWALL
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2025 | ENGR Engineering Final | Passed | Site is clear from any repair work. | |
| 11/14/2025 | BULD - Electrical Clearance | Passed | 11-14-25: okay to energize meter 157584487. RECN issued to TEP. | |
| 12/05/2025 | COT - HCPL - Gas Pressure Test | Passed | 12.4.25 Approved |
|
| 12/11/2025 | COT - LCEL - Electrical Intermediate | Passed | 12-11-25: electrical intermediates approved. Schedule plumbing & mechanical intermediates when ready. |
|
| 02/18/2026 | COT - HCPL - Plumbing Intermediate | Passed | ||
| 02/18/2026 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 02/18/2026 | COT - LCBU - Roof Nailing | Passed | ||
| 02/19/2026 | COT - LCME - Mechanical Intermediate | Passed | ||
| 02/19/2026 | COT - LCBU - Framing | Passed | ||
| 03/27/2026 | COT - HCBU - Interior Shear Bracing | Passed | 3-27-26: interior shear bracing approved. Okay to tape & texture. | |
| 05/18/2026 | COT - LCEL - Electrical Final | Passed | 5/18/2026 approved. All corrections were made. | |
| 09/02/2026 | COT - LCME - Mechanical Final | Passed | ||
| 09/03/2026 | TRSP - ROW - Notice of Completion | Passed | no impact to right of way, restoration strictly limited to the structure on private property | |
| 10/22/2026 | COT - BULD - SWG Clearance | Passed | 10/22/26: okay to install gas meter-SWG clearance issued. |