Permit: TC-COM-0425-00783

Parcel: 140327000


Addresses:

6024 S KIRTLEY DR

Inspection Status: Re-inspection required

Inspection History: COT - LCME - Mechanical Intermediate

Date Description Inspector Results Comments
01/06/2026 COT - LCME - Mechanical Intermediate Re-inspection required 1-6-26: secure exhaust at laundry room, add grommet to bathroom fans where awg wires are fed into fans, support fan exhaust above tub, remove tape at exhaust b-vent, add Boca plates to marked locations at laundry room, support bathroom exhaust horizontally- 1st floor bathroom, wye flex at master bathroom upstairs shall be installed horizontally, frame Chase and fire foam edges, support flex throughout upstairs, vapor barrier throughout 1st & 2nd floor must be repaired/replaced.
NOTE: schedule framing inspection. This inspection is required for this permit.
02/05/2026 COT - LCME - Mechanical Intermediate Re-inspection required 2-5-26: add a support for upstairs exhaust above tub, fire foam all edges/perimeter at osb in chute, support flex at upstairs-flex cannot lie directly on top of trusses, missing grommet at master bathroom's fan, fire foam penetration at top plate adjacent to upstairs tub. Provide UL listing for zip ties that were used to support the horizontal exhaust at the 1st floor bathroom-you may use zip ties as a means of support so long as it is rated for that purpose with a UL Listing of UL181 B. Everything requiring corrections with the exception of flex has been marked in red for you.
02/12/2026 COT - LCME - Mechanical Intermediate Re-inspection required (with fee) 2-12-26: Two of the items listed for correction from inspection on 2/5/26 have not been addressed. Missing fire foam at the top plate adjacent to tub in bedroom facing southeast together with the chute. These locations were previously marked in red and I remarked the areas again and added today's to better assist you finding the locations.
02/17/2026 COT - LCME - Mechanical Intermediate Re-inspection required 2-17-26: chute is not sealed-you must seal entire perimeter of chute and not just around the flex. Reschedule inspection, set a time-bring fire foam and will meet you here on site and show you exactly where fire foam is required.
02/18/2026 COT - LCME - Mechanical Intermediate Re-inspection required 2/18/26: per previous inspection noted on 2-5-26 and 1/6/26 (flex duct shall be properly secured throughout), per inspection on 1/6/26 (B-vent shall maintain 1" clearance from combustibles at 2nd story), drain lines running horizontal between floors shall be properly secured every 4', properly secure walls at first floor closet bedroom and 2nd floor master bedroom, all penetrations at vapor barrier shall be sealed (2nd floor, marked with red marker).
02/19/2026 COT - LCME - Mechanical Intermediate Passed
12/18/2025 COT - LCME - Mechanical Intermediate Re-inspection required 12-18-25: block all registers on 3 sides throughout, firefoam all horizontal penetrations from an unconditioned to conditioned space from garage to living space, frame open space from ground level to second floor at chase and firefoam any opening, firefoam 1st to 2nd floor penetrations at loft, firefoam top plate penetration at loft. STOPPED INSPECTION -ADDITIONAL ITEMS MAY ADDED.