Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Commercial Building
Apply Date:
04/16/2024
Applicant:
Laura Moreno
Description:
Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.

Permit Reviews

Permit Number - TC-COM-0424-00685
Permit Status: Issued
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Start Date Submittal Complete Date Status  
09/03/2025 RESTAMP - COMMERCIAL v.1 09/04/2025 APPROVED Review Details
03/17/2025 RESTAMP - COMMERCIAL v.1 03/20/2025 APPROVED Review Details
05/14/2024 COMMERCIAL REVIEW - FULL v.1 05/14/2024 REQUIRES RESUBMIT Review Details
02/11/2025 COMMERCIAL REVIEW - FULL v.1 03/13/2025 REQUIRES RESUBMIT Review Details
08/28/2025 COMMERCIAL REVIEW - FULL REVISION v.2 09/03/2025 APPROVED Review Details
05/14/2024 COMMERCIAL REVIEW - LIMITED v.2 05/29/2024 APPROVED Review Details
04/22/2024 COMMERCIAL REVIEW - LIMITED v.1 05/07/2024 REQUIRES RESUBMIT Review Details
03/14/2025 COMMERCIAL REVIEW - FULL v.2 03/17/2025 APPROVED Review Details
07/31/2025 COMMERCIAL REVIEW - FULL REVISION v.1 08/25/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0424-00685
Permit Status: Issued
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Total Outstanding Activity Conditions - 1
Date Name
05/29/2024 AIR BALANCING REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0424-00685
Permit Status: Issued
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Date Description Comments
05/06/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-0424-00685
Permite Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
05/29/2025 COT - LCEL - Electrical Intermediate N/A Not Ready
09/17/2025 COT - LCPL - Plumbing Intermediate N/A Partial Pass 9-17-25: new underground plumbing for a new shower & water station located at Area B approved-Okay to backfill progress areas.
09/30/2025 COT - LCBU - Framing N/A Partial Pass 9-30-25: drywall nailing for area b approved. Okay for tape & texture.
11/24/2025 COT - LCEL - Electrical Underground N/A Partial Pass 11-24-25: verified electrical underground conduit, ground rods & 3/0 copper at 30" below grade for HazMat container located at exterior northwest corner of building. Okay to backfill progress areas with the use of shading materials and continue with cons at progress areas.
12/17/2025 COT - LCME - Mechanical Intermediate N/A Re-inspection required 12-17-25: copper air line, fire sprinkler, together with condensation copper line above ceiling cannot be in contact with other metals-add 10 mil tape or install copper hangers, add insulation around pookie joints, replace/add duct hanger on south end of shipping/receiving/control area.
12/17/2025 COT - LCEL - Electrical Above Ceiling N/A Re-inspection required 12-17-25: remove unused/old conduit above ceiling at entry to shipping/receiving at north wall, label all junction boxes, add knockouts to junction boxes where needed, secure/install clamp to conduit located on south wall.

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-0424-00685
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Total Completed Inspections - 3
Date Description Inspector Results Comments
03/25/2025 BULD - Electrical Clearance Passed 2705 E. Medina STE 111-2. (meter #2)
09/17/2025 PDSD Building Division - Demo - Final Passed 9-17-25: demo final approved.
09/19/2025 COT - LCBU - Excavation/Rebar/Zoning Passed 9-19-25: reinforcement at pour back sections in Area B verified per plans-okay for concrete placement at progress areas.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-42315.00-FULL SET-REV-25-0828_V2.PDF DOCUMENTS VIEW
CONS-42315.00-FULL-REV-RESPONSE 25-0312_V2.PDF DOCUMENTS VIEW
SPAPP-REVISION RESPONSE LETTER-25-0312-2025-03-13_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-42315.00-IFP DEMO SET-24-0401_V1-REV1 SET-24-0509_V2.PDF DOCUMENTS VIEW