Permit Details

Status:
Issued
Type:
Commercial Building
Apply Date:
04/16/2024
Applicant:
Laura Moreno
Description:
Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.

Permit Reviews

Permit Number - TC-COM-0424-00685
Permit Status: Issued
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Start Date Submittal Complete Date Status  
09/03/2025 RESTAMP - COMMERCIAL v.1 09/04/2025 APPROVED Review Details
03/17/2025 RESTAMP - COMMERCIAL v.1 03/20/2025 APPROVED Review Details
05/14/2024 COMMERCIAL REVIEW - FULL v.1 05/14/2024 REQUIRES RESUBMIT Review Details
02/11/2025 COMMERCIAL REVIEW - FULL v.1 03/13/2025 REQUIRES RESUBMIT Review Details
08/28/2025 COMMERCIAL REVIEW - FULL REVISION v.2 09/03/2025 APPROVED Review Details
05/14/2024 COMMERCIAL REVIEW - LIMITED v.2 05/29/2024 APPROVED Review Details
04/22/2024 COMMERCIAL REVIEW - LIMITED v.1 05/07/2024 REQUIRES RESUBMIT Review Details
03/14/2025 COMMERCIAL REVIEW - FULL v.2 03/17/2025 APPROVED Review Details
07/31/2025 COMMERCIAL REVIEW - FULL REVISION v.1 08/25/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0424-00685
Permit Status: Issued
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Total Outstanding Activity Conditions - 1
Date Name
05/29/2024 AIR BALANCING REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0424-00685
Permit Status: Issued
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Date Description Comments
05/06/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-0424-00685
Permite Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
11/24/2025 COT - LCEL - Electrical Underground N/A Partial Pass 11-24-25: verified electrical underground conduit, ground rods & 3/0 copper at 30" below grade for HazMat container located at exterior northwest corner of building. Okay to backfill progress areas with the use of shading materials and continue with cons at progress areas.
02/25/2026 COT - LCEL - Electrical Final N/A Re-inspection required 2-25-26: install permanent label on panel CP1.
02/25/2026 COT - LCME - Mechanical Final N/A Re-inspection required 2-25-26: pookie exhaust and wrap at warehouse, seal penetration at east wall into next door suite at warehouse, complete air compressor copper tie at warehouse and add vertical & horizontal supports on copper line, warehouse missing hose at mop sink.
12/22/2025 COT - LCEL - Electrical Above Ceiling N/A Partial Pass 12-22-25: partial pass-okay to continue with construction at quality control & shipping/receiving areas.
12/22/2025 COT - LCME - Mechanical Intermediate N/A Partial Pass 12-22-25: partial pass-okay to continue with construction at quality control & shipping/receiving areas.
01/21/2026 COT - LCPL - Plumbing Intermediate N/A Canceled 1-21-26: canceled by contractor.
01/26/2026 COT - LCEL - Electrical Intermediate N/A Re-inspection required 1-26-26: label all junction boxes above ceiling, hot copper water lines 3/4" or larger must be insulation with minimum of R3, add 10 mil tape to all locations where copper lines are in contact with seismic wires, provide supports to copper lines that are resting directly on top of ceiling grid (supports attached directly to the ceiling grid is not allowed). Reschedule inspection when corrections are made.

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-0424-00685
Permit Description: Open Office area's height for multi-purpose option. Includes ceiling & associated mech, elec REV1: expanding area of work and installing equipment, self-contained chemical storage in the private yard REV2: The additional scope that includes expanding the area of work to house new equipment and adding a new unisex shower, janitor’s closet with a mop sink, and a new storage closet. This revision includes the architectural, mechanical, and electrical improvements required for the updated scope.
Total Completed Inspections - 10
Date Description Inspector Results Comments
03/25/2025 BULD - Electrical Clearance Passed 2705 E. Medina STE 111-2. (meter #2)
09/17/2025 PDSD Building Division - Demo - Final Passed 9-17-25: demo final approved.
09/19/2025 COT - LCBU - Excavation/Rebar/Zoning Passed 9-19-25: reinforcement at pour back sections in Area B verified per plans-okay for concrete placement at progress areas.
12/22/2025 COT - LCBU - Framing Passed 12-22-25: framing approved.
01/21/2026 COT - LCEL - Electrical Underground Passed 1-21-26: approved.
02/25/2026 COT - FCON - Sprinkler - Final Passed passed on 7/10/2024
02/25/2026 COT - LCEL - Electrical Above Ceiling Passed 2-25-26: approved.
02/25/2026 COT - LCME - Mechanical Intermediate Passed 2-25-26: approved.
02/25/2026 COT - LCPL - Plumbing Intermediate Passed 2-25-26: approved.
02/25/2026 COT - LCEL - Electrical Intermediate Passed 2-25-26: approved.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-42315.00-FULL SET-REV-25-0828_V2.PDF DOCUMENTS VIEW
CONS-42315.00-FULL-REV-RESPONSE 25-0312_V2.PDF DOCUMENTS VIEW
SPAPP-REVISION RESPONSE LETTER-25-0312-2025-03-13_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-42315.00-IFP DEMO SET-24-0401_V1-REV1 SET-24-0509_V2.PDF DOCUMENTS VIEW