Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
01/28/2015
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
RESTAURANT
Contractors:
  • RELIANCE COMMERCIAL CONSTRUCTION

Permit Reviews

Permit Number - T15CM00578
Permit Status: C of o
Permit Description: RESTAURANT
Start Date Submittal Complete Date Status  
01/28/2015 COMMERCIAL - TI 01/29/2015 COMPLETED Review Details
01/29/2015 COMMERCIAL - BLDG/FIRE/ZONING/ENG 02/26/2015 COMPLETED Review Details
02/26/2015 WALK THRU - COMM 02/26/2015 COMPLETED Review Details
02/26/2015 OTHER 02/27/2015 COMPLETED Review Details
04/28/2015 REVISION - - 1ST 06/18/2015 COMPLETED Review Details
06/18/2015 REVISION - - 2ND 06/25/2015 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T15CM00578
Permit Status: C of o
Permit Description: RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
01/28/2015 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T15CM00578
Permit Description: RESTAURANT
Total Completed Inspections - 26
Date Description Inspector Results Comments
03/16/2015 PLUMBING - ROUGH, SOIL BBENEDOI Approved PROVIDE FULL SIZE CO @ WALL AS SHOWN
03/23/2015 ELECTRIC - PROGRESS JMILITEL Approved IVRS - Inspection :*
03/25/2015 SHEET ROCK NAILING JMILITEL Approved IVRS - Inspection :*
04/07/2015 PLUMBING - GAS PRESSURE TEST JMILITEL Approved IVRS - Inspection :*
04/07/2015 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
04/07/2015 PLUMBING - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
04/07/2015 ELECTRIC - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
04/07/2015 STUCCO MESH JMILITEL Approved IVRS - Inspection :*
04/07/2015 FRAMING JMILITEL Approved IVRS - Inspection :*
04/15/2015 MECHANICAL - HOODS JMILITELLO Approved OK TO DOUBLE WRAP GREASE DUCT WITH OFFSET
04/15/2015 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
04/28/2015 PLUMBING - PROGRESS JMILITEL Approved IVRS - Inspection :*
05/04/2015 BUILDING ABOVE CEILING JMILITELLO Approved OK FOR CEILING TILES. STILL NEED TO SEE FINAL CONNECTIONS AT ANSUL VALVE
05/04/2015 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
05/04/2015 PLUMBING - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
05/04/2015 ELECTRIC - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
05/04/2015 BUILDING ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
06/17/2015 FIRE - KITCHEN EXH HOOD FINAL nspreng1 Approved PULL STATION AND LINK PASSED.
ALL GAS AND ELECTRIC UNDER HOOD SHUT DOWN.
MAKE UP AIR SHUT DOWN AND EXHAUST STAYED ON. ALL NOZZLES ARE WITHIN DESIGN PER PLANS. HOOD SYSTEM IS TIED INTO ALARM SYSTEM AND NOTIFICATION DEVICES ALL ACITIVATED AND ALARM WAS RECIEVED AT THE PANEL AND THE MONITORING COMPANY AS AN 'ALARM' WITH A RESET.
06/17/2015 FIRE SPKLR - FINAL nspreng1 Approved SPRINKLER HEAD ADDED WHERE UPRIGHT WAS CAPPED. INSULATION MOVED AWAY FROM UPRIGHT IN KITCHEN ( OVERHEAD)
SIGNS ON SPRINKLER RISER ROOM DOOR.
REPLACED PAINTED HEAD.
NO AS BUILDS REQUIRED - NO ADDITIONAL HEADS.
06/19/2015 FIRE - ALARM FINAL nspreng1 Approved
06/23/2015 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
06/23/2015 PLUMBING - FINAL JMILITEL Approved IVRS - Inspection :*
06/23/2015 ELECTRIC - FINAL JMILITEL Approved IVRS - Inspection :*
06/24/2015 HEALTH DEPT - FINAL 724-7908 ELOPEZ Approved
06/25/2015 BUILDING - FINAL JMILITEL Approved IVRS - Inspection :*
06/25/2015 FIRE - FINAL MBROWN Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW
001_TS.1.TIF CONSTRPLANS VIEW
002_101.TIF CONSTRPLANS VIEW
003_D.1.TIF CONSTRPLANS VIEW
004_A.1.TIF CONSTRPLANS VIEW
005_A1.1.TIF CONSTRPLANS VIEW
006_A.2.TIF CONSTRPLANS VIEW
007_A.3.TIF CONSTRPLANS VIEW
008_A.4.TIF CONSTRPLANS VIEW
009_K1.TIF CONSTRPLANS VIEW
010_K2.TIF CONSTRPLANS VIEW
011_K2.1.TIF CONSTRPLANS VIEW
012_K3.TIF CONSTRPLANS VIEW
013_K3.1.TIF CONSTRPLANS VIEW
014_K4.TIF CONSTRPLANS VIEW
015_K5.TIF CONSTRPLANS VIEW
016_K5.1.TIF CONSTRPLANS VIEW
017_M1.TIF CONSTRPLANS VIEW
018_MP.1.TIF CONSTRPLANS VIEW
019_M.2.TIF CONSTRPLANS VIEW
020_M.3.TIF CONSTRPLANS VIEW
021_M.4.TIF CONSTRPLANS VIEW
022_M.5.TIF CONSTRPLANS VIEW
023_M.8.TIF CONSTRPLANS VIEW
024_P1.1.TIF CONSTRPLANS VIEW
025_P2.1.TIF CONSTRPLANS VIEW
026_P3.1.TIF CONSTRPLANS VIEW
027_P4.1.TIF CONSTRPLANS VIEW
028_E.1.TIF CONSTRPLANS VIEW
029_E.2.TIF CONSTRPLANS VIEW
030_E.3.TIF CONSTRPLANS VIEW
031_E.4.TIF CONSTRPLANS VIEW
032_E.5.TIF CONSTRPLANS VIEW
033_E.6.TIF CONSTRPLANS VIEW
001_S.2.TIF CONSTRPLANS VIEW
002_S.3.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW