Permit Reviews
Permit Number - T11CM00617
Permit Status: C of o
Permit Description: SENIOR HOUSING APARTMENTS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/20/2012 | REVISION - - 2ND | 01/20/2012 | COMPLETED |
| 02/15/2012 | REVISION - - 3RD | 02/16/2012 | COMPLETED |
| 02/16/2012 | REVISION - - 3RD | 02/17/2012 | COMPLETED |
| 02/28/2011 | PLANS OK TO SUBMIT - COMM | 02/28/2011 | COMPLETED |
| 02/28/2011 | COMMERCIAL - NEW | 03/23/2011 | COMPLETED |
| 03/31/2011 | RESUBMITTAL - TI ALL | 04/20/2011 | COMPLETED |
| 04/20/2011 | RESUBMITTAL - TI ALL | 05/19/2011 | COMPLETED |
| 07/21/2011 | REVISION - - 1ST | 07/25/2011 | COMPLETED |
| 12/15/2011 | REVISION - - 2ND | 01/19/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T11CM00617
Permit Status: C of o
Permit Description: SENIOR HOUSING APARTMENTS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/28/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T11CM00617
Permit Description: SENIOR HOUSING APARTMENTS
Total Completed Inspections - 46
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2011 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* 1) GL: 3-P-1, P-G/1 2) ELEVATOR PIT AT M-D/2-3 |
| 07/08/2011 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection :* 1) LINE K-6 |
| 07/19/2011 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* 1) RETAINING WALL FOOTER GL B-C/2; G.4/P/01 |
| 07/19/2011 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/25/2011 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) BLDG #2 PVC UNDERGROUND OK |
| 08/01/2011 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 08/05/2011 | PLUMBING - PRE SLAB | RRICH | Approved | IVRS - Inspection :* |
| 08/08/2011 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* 1) GL 1-15/P-J |
| 11/16/2011 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 11/18/2011 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* 1) OK SECONDARIES FROM BLDG TO SES. 2) PROTECT M/C PER 300.4 (1 1/4") 3) KITCHEN COUNTER RECEPTS PER 210.52 (C) |
| 11/30/2011 | ELECTRIC - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* 1) 1ST FLOOR UNITS 101 THRU 119 |
| 12/02/2011 | PLUMBING - ROOF DRAINS | RMYERS | Approved | IVRS - Inspection :* |
| 12/05/2011 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* 1) MEDIUM PRESSURE GAS MAIN DOWN CORRIDOR OK 2) 60 POUND TEST OK |
| 12/23/2011 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1) 2ND & 3RD FLOOR DWV OK PEX OK OK TO INSULATE HOT & RETURN NEED TO SEE FLANGES |
| 12/28/2011 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | 2nd lift/ 5th floor/ east wing complete |
| 12/29/2011 | FRAMING | LHANLY | Approved | |
| 02/22/2012 | FIRE SPKLR - UG, PIPING, HYDRO | DSIWARSKI | Approved | |
| 05/17/2012 | SHEET ROCK NAILING | BBENEDON | Approved | 6TH FLOOR |
| 05/25/2012 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR #221 &321 PER R. MORENO |
| 06/18/2012 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/18/2012 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/22/2012 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 06/26/2012 | FIREWALL/FIREBARRIER/FIRESTOP | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/26/2012 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/26/2012 | PLUMBING - SEWER HCS CONNECT | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/26/2012 | PLUMBING - ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/27/2012 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 06/28/2012 | MECHANICAL - HYDRONIC PIPING | MRAMBER | Approved | IVRS - Inspection :* |
| 07/09/2012 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 07/10/2012 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
| 07/12/2012 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 07/13/2012 | NPPO - FINAL | RLEDONNE | Approved | |
| 07/13/2012 | SIGN - FINAL | RLEDONNE | Approved | |
| 07/13/2012 | LANDSCAPE - FINAL | RLEDONNE | Approved | |
| 07/16/2012 | PLUMBING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/16/2012 | PLUMBING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/17/2012 | RIGHT OF WAY - FINAL | TWOLFGAN | Approved | |
| 07/18/2012 | ZONING - FINAL | RLEDONNE | Approved | |
| 07/18/2012 | ENGINEERING - FINAL | RLEDONNE | Approved | |
| 07/20/2012 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 07/25/2012 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/26/2012 | CERTIFICATE OF OCCUPANCY | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/26/2012 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/27/2012 | FIRE SPKLR - FINAL | WMOTTO | Approved | |
| 07/30/2012 | FIRE - FINAL | KENB | Approved | As builts plans were given to Fire Code Administrator. |
| 07/30/2012 | FIRE - ALARM FINAL | KENB | Approved |