Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
125 S LINDA AV
Address NEW:
125 S LINDA AV
Apply Date:
02/28/2011
Applicant:
N/A
Description:
SENIOR HOUSING APARTMENTS
Contractors:
  • W E O'NEIL

Permit Reviews

Permit Number - T11CM00617
Permit Status: C of o
Permit Description: SENIOR HOUSING APARTMENTS
Start Date Submittal Complete Date Status  
01/20/2012 REVISION - - 2ND 01/20/2012 COMPLETED Review Details
02/15/2012 REVISION - - 3RD 02/16/2012 COMPLETED Review Details
02/16/2012 REVISION - - 3RD 02/17/2012 COMPLETED Review Details
02/28/2011 PLANS OK TO SUBMIT - COMM 02/28/2011 COMPLETED Review Details
02/28/2011 COMMERCIAL - NEW 03/23/2011 COMPLETED Review Details
03/31/2011 RESUBMITTAL - TI ALL 04/20/2011 COMPLETED Review Details
04/20/2011 RESUBMITTAL - TI ALL 05/19/2011 COMPLETED Review Details
07/21/2011 REVISION - - 1ST 07/25/2011 COMPLETED Review Details
12/15/2011 REVISION - - 2ND 01/19/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM00617
Permit Status: C of o
Permit Description: SENIOR HOUSING APARTMENTS
Total Outstanding Activity Conditions - 1
Date Name
02/28/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T11CM00617
Permit Description: SENIOR HOUSING APARTMENTS
Total Completed Inspections - 46
Date Description Inspector Results Comments
07/07/2011 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
1) GL: 3-P-1, P-G/1
2) ELEVATOR PIT AT M-D/2-3
07/08/2011 ELECTRIC - UFER AQUIROZ Approved IVRS - Inspection :*
1) LINE K-6
07/19/2011 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
1) RETAINING WALL FOOTER GL B-C/2; G.4/P/01
07/19/2011 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
07/25/2011 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1) BLDG #2 PVC UNDERGROUND OK
08/01/2011 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
08/05/2011 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
08/08/2011 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
1) GL 1-15/P-J
11/16/2011 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
11/18/2011 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
1) OK SECONDARIES FROM BLDG TO SES.
2) PROTECT M/C PER 300.4 (1 1/4")
3) KITCHEN COUNTER RECEPTS PER 210.52 (C)
11/30/2011 ELECTRIC - INTERMEDIATE AQUIROZ Approved IVRS - Inspection :*
1) 1ST FLOOR UNITS 101 THRU 119
12/02/2011 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :*
12/05/2011 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection :*
1) MEDIUM PRESSURE GAS MAIN DOWN CORRIDOR OK
2) 60 POUND TEST OK
12/23/2011 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1) 2ND & 3RD FLOOR DWV OK PEX OK
OK TO INSULATE HOT & RETURN
NEED TO SEE FLANGES
12/28/2011 REINFORCED MASONRY PRE-GROUT LHANLY Approved 2nd lift/ 5th floor/ east wing complete
12/29/2011 FRAMING LHANLY Approved
02/22/2012 FIRE SPKLR - UG, PIPING, HYDRO DSIWARSKI Approved
05/17/2012 SHEET ROCK NAILING BBENEDON Approved 6TH FLOOR
05/25/2012 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR #221 &321 PER R. MORENO
06/18/2012 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
06/18/2012 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
06/22/2012 PLUMBING - GAS PRESS TEST FNL RMYERS Approved IVRS - Inspection :*
06/26/2012 FIREWALL/FIREBARRIER/FIRESTOP AQUIROZ Approved IVRS - Inspection :*
06/26/2012 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
06/26/2012 PLUMBING - SEWER HCS CONNECT AQUIROZ Approved IVRS - Inspection :*
06/26/2012 PLUMBING - ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
06/27/2012 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
06/28/2012 MECHANICAL - HYDRONIC PIPING MRAMBER Approved IVRS - Inspection :*
07/09/2012 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
07/10/2012 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
07/12/2012 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
07/13/2012 NPPO - FINAL RLEDONNE Approved
07/13/2012 SIGN - FINAL RLEDONNE Approved
07/13/2012 LANDSCAPE - FINAL RLEDONNE Approved
07/16/2012 PLUMBING - FINAL AQUIROZ Approved IVRS - Inspection :*
07/16/2012 PLUMBING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
07/17/2012 RIGHT OF WAY - FINAL TWOLFGAN Approved
07/18/2012 ZONING - FINAL RLEDONNE Approved
07/18/2012 ENGINEERING - FINAL RLEDONNE Approved
07/20/2012 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
07/25/2012 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
07/26/2012 CERTIFICATE OF OCCUPANCY AQUIROZ Approved IVRS - Inspection :*
07/26/2012 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
07/27/2012 FIRE SPKLR - FINAL WMOTTO Approved
07/30/2012 FIRE - FINAL KENB Approved As builts plans were given to Fire Code Administrator.
07/30/2012 FIRE - ALARM FINAL KENB Approved

Documents

File Name Document Type  
C OF O_07-30-2012.TIF CERT OF OCC VIEW
TEMP C OF O_07-27-2012.TIF CERT OF OCC VIEW
001_A0.0.TIF CONSTRPLANS VIEW
002_A0.1.TIF CONSTRPLANS VIEW
003_A0.2.TIF CONSTRPLANS VIEW
004_C1.TIF CONSTRPLANS VIEW
005_C2.TIF CONSTRPLANS VIEW
006_C3.TIF CONSTRPLANS VIEW
007_C4.TIF CONSTRPLANS VIEW
008_C5.TIF CONSTRPLANS VIEW
009_C6.TIF CONSTRPLANS VIEW
010_A1.1.TIF CONSTRPLANS VIEW
011_A2.1.TIF CONSTRPLANS VIEW
012_A2.2.TIF CONSTRPLANS VIEW
013_A2.3.TIF CONSTRPLANS VIEW
014_A2.4.TIF CONSTRPLANS VIEW
015_A2.5.TIF CONSTRPLANS VIEW
016_A2.6.TIF CONSTRPLANS VIEW
017_A3.1.TIF CONSTRPLANS VIEW
018_A3.2.TIF CONSTRPLANS VIEW
019_A3.3.TIF CONSTRPLANS VIEW
020_A3.4.TIF CONSTRPLANS VIEW
021_A4.1.TIF CONSTRPLANS VIEW
022_A4.2.TIF CONSTRPLANS VIEW
023_A5.1.TIF CONSTRPLANS VIEW
024_A5.2.TIF CONSTRPLANS VIEW
025_A6.1.TIF CONSTRPLANS VIEW
026_A7.1.TIF CONSTRPLANS VIEW
027_A8.1.TIF CONSTRPLANS VIEW
028_A8.2.TIF CONSTRPLANS VIEW
029_A9.1.TIF CONSTRPLANS VIEW
030_A9.2.TIF CONSTRPLANS VIEW
031_S1.0.TIF CONSTRPLANS VIEW
032_S1.1.TIF CONSTRPLANS VIEW
033_S1.2.TIF CONSTRPLANS VIEW
034_S1.3.TIF CONSTRPLANS VIEW
035_S1.4.TIF CONSTRPLANS VIEW
036_S1.5.TIF CONSTRPLANS VIEW
037_S1.6.TIF CONSTRPLANS VIEW
038_S2.0.TIF CONSTRPLANS VIEW
039_S2.1.TIF CONSTRPLANS VIEW
040_S2.2.TIF CONSTRPLANS VIEW
041_S2.3.TIF CONSTRPLANS VIEW
042_S2.4.TIF CONSTRPLANS VIEW
043_S2.5.TIF CONSTRPLANS VIEW
044_S2.6.TIF CONSTRPLANS VIEW
045_S2.7.TIF CONSTRPLANS VIEW
046_S3.0.TIF CONSTRPLANS VIEW
047_S3.1.TIF CONSTRPLANS VIEW
048_S4.0.TIF CONSTRPLANS VIEW
049_S4.1.TIF CONSTRPLANS VIEW
050_S5.0.TIF CONSTRPLANS VIEW
051_S5.1.TIF CONSTRPLANS VIEW
052_S5.2.TIF CONSTRPLANS VIEW
053_S6.0.TIF CONSTRPLANS VIEW
054_S6.1.TIF CONSTRPLANS VIEW
055_IS1.1.TIF CONSTRPLANS VIEW
056_IS1.2.TIF CONSTRPLANS VIEW
057_IS2.1.TIF CONSTRPLANS VIEW
058_IS3.1.TIF CONSTRPLANS VIEW
059_IS3.2.TIF CONSTRPLANS VIEW
060_IS3.3.TIF CONSTRPLANS VIEW
061_IS3.4.TIF CONSTRPLANS VIEW
062_IS3.5.TIF CONSTRPLANS VIEW
063_IS3.6.TIF CONSTRPLANS VIEW
064_IS3.7.TIF CONSTRPLANS VIEW
065_IS3.8.TIF CONSTRPLANS VIEW
066_IS3.9.TIF CONSTRPLANS VIEW
067_IS4.0.TIF CONSTRPLANS VIEW
068_M1.1.TIF CONSTRPLANS VIEW
069_M1.2.TIF CONSTRPLANS VIEW
070_M1.3.TIF CONSTRPLANS VIEW
071_M1.4.TIF CONSTRPLANS VIEW
072_M1.5.TIF CONSTRPLANS VIEW
073_M1.6.TIF CONSTRPLANS VIEW
074_M1.7.TIF CONSTRPLANS VIEW
075_M2.1.TIF CONSTRPLANS VIEW
076_M2.2.TIF CONSTRPLANS VIEW
077_M3.1.TIF CONSTRPLANS VIEW
078_M4.1.TIF CONSTRPLANS VIEW
079_M4.2.TIF CONSTRPLANS VIEW
080_M4.3.TIF CONSTRPLANS VIEW
081_M4.4.TIF CONSTRPLANS VIEW
082_M4.5.TIF CONSTRPLANS VIEW
083_M4.6.TIF CONSTRPLANS VIEW
084_M4.7.TIF CONSTRPLANS VIEW
085_M5.1.TIF CONSTRPLANS VIEW
086_M5.2.TIF CONSTRPLANS VIEW
087_M6.1.TIF CONSTRPLANS VIEW
088_M6.2.TIF CONSTRPLANS VIEW
089_P1.1.TIF CONSTRPLANS VIEW
090_P1.2.TIF CONSTRPLANS VIEW
091_P1.3.TIF CONSTRPLANS VIEW
092_P1.4.TIF CONSTRPLANS VIEW
093_P1.5.TIF CONSTRPLANS VIEW
094_P1.6.TIF CONSTRPLANS VIEW
095_P1.7.TIF CONSTRPLANS VIEW
096_P1.8.TIF CONSTRPLANS VIEW
097_P2.1.TIF CONSTRPLANS VIEW
098_P3.1.TIF CONSTRPLANS VIEW
099_P4.1.TIF CONSTRPLANS VIEW
100_P4.2.TIF CONSTRPLANS VIEW
101_P4.3.TIF CONSTRPLANS VIEW
102_P5.1.TIF CONSTRPLANS VIEW
103_P5.2.TIF CONSTRPLANS VIEW
104_FP-1.TIF CONSTRPLANS VIEW
105_FP-2.TIF CONSTRPLANS VIEW
106_FP-3.TIF CONSTRPLANS VIEW
107_FP-4.TIF CONSTRPLANS VIEW
108_FP-5.TIF CONSTRPLANS VIEW
109_FP-6.TIF CONSTRPLANS VIEW
110_E0.1.TIF CONSTRPLANS VIEW
111_E1.1.TIF CONSTRPLANS VIEW
112_E2.1.TIF CONSTRPLANS VIEW
113_E2.2.TIF CONSTRPLANS VIEW
114_E2.3.TIF CONSTRPLANS VIEW
115_E2.4.TIF CONSTRPLANS VIEW
116_E3.1.TIF CONSTRPLANS VIEW
117_E3.2.TIF CONSTRPLANS VIEW
118_E3.3.TIF CONSTRPLANS VIEW
119_E3.4.TIF CONSTRPLANS VIEW
120_E3.5.TIF CONSTRPLANS VIEW
121_E4.1.TIF CONSTRPLANS VIEW
122_E5.1.TIF CONSTRPLANS VIEW
123_E5.2.TIF CONSTRPLANS VIEW
124_E6.1.TIF CONSTRPLANS VIEW
125_E6.2.TIF CONSTRPLANS VIEW
126_E6.3.TIF CONSTRPLANS VIEW
127_E7.1.TIF CONSTRPLANS VIEW
128_E7.2.TIF CONSTRPLANS VIEW
129_E7.3.TIF CONSTRPLANS VIEW
130_E7.4.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW