Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T11CM00617
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/20/2012 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 04/03/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT ON SITE WALL PROGRESS AREA |
|
| 03/30/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 03/28/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT ON INFILL |
|
| 03/27/2012 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 03/23/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT 6TH FLOOR IN FILL |
|
| 03/23/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) 2ND LIFT AT 6TH FLOOR INFILL | |
| 03/22/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) IN FILL UP TO 6TH FLOOR |
|
| 03/21/2012 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 03/16/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT 5TH FLOOR IN FILL |
|
| 03/15/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT 5TH FLOOR IN FILL |
|
| 03/14/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4TH FLOOR INFILL |
|
| 03/12/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT INFILL |
|
| 03/09/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT 2ND FLOOR INFILL |
|
| 02/10/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 02/09/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT AT ---- |
|
| 02/08/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GL B-M/1 & 2 PARAPET OK GL A-M/6 & 7 PARAPET OK |
|
| 01/25/2012 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 01/24/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT PARAPET ON EAST WING |
|
| 01/23/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) PARAPET ON GL: Q/1-9, 2ND LIFT P/1-7 EAST WING |
|
| 01/21/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL P/7.5 1ST LIFT, 2ND LIFT ON ELEVATOR SHAFT THE FLOOR 2) AFTER HOURS INSPECTION $165.00 PAID WITH CHECK #10750 |
|
| 01/20/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M/1-7 2ND LIFT 6TH FLOOR AND 1ST LIFT ON ELEVATOR SHAFT 6TH FLOOR |
|
| 01/19/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: K/1-7 2ND LIFT 6TH FLOOR, M/1-7 1ST LIFT 6TH FLOOR |
|
| 01/18/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: J/2-7 2ND LIFT 6TH FLOOR |
|
| 01/17/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) J-M/2-7 1ST LIFT 4TH FLOOR |
|
| 01/13/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL H & J/1-7 1ST LIFT, G & H/1-7 2ND LIFT 6TH FLOOR |
|
| 01/12/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: C-F/4 2ND LIFT, G/4-7, D/4-7, F/4-7 M/ 2ND LIFT 6TH FLOOR |
|
| 01/11/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: B.8/4-7, C/2-4, C-F/2 ALL 2ND LIFT 6TH FLOOR |
|
| 01/10/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL D-G/4-7 1ST LIFT 6TH FLOOR, G/2-4 1ST LIFT, D-J/7 1ST LIFT 6TH FLOOR |
|
| 01/09/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: G-J/1 1ST LIFT, G/2-4 1ST LIFT 6TH FLOOR |
|
| 01/06/2012 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: C-G/1 1ST LIFT 6TH FLOOR, 4-7/A 1ST LIFT AND C/4-7 1ST LIFT 6TH FLOOR |
|
| 01/05/2012 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) GL: B/1-4 BOND BEAM, C/2-4 BOND BEAM |
|
| 12/28/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2nd lift/ 5th floor/ east wing complete | |
| 12/27/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 5TH FLOOR/ 1ST LIFT/ EAST WING | |
| 12/22/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 12/21/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: 3-12/Q 1ST LIFT 5TH FLOOR, .05-8.5/P 1ST LIFT 5TH FLOOR |
|
| 12/20/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: Q/1-8 1ST LIFT 5TH FLOOR |
|
| 12/19/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) H/1-7 1ST LIFT, J/1-7 ?, K/1-7 1ST LIFT, M/1-7 1ST LIFT 5TH FLOOR |
|
| 12/19/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL: J/1-7, K/1-7, M/1-7 2ND LIFT 5TH FLOOR | |
| 12/15/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) J/1-3 2ND LIFT 5TH FLOOR AND G-J/1 2ND LIFT 5TH FLOOR |
|
| 12/13/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/12/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | CANCELLED DUE TO RAIN | |
| 12/09/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL F/4-7, E/4-7, G-4-7 2ND LIFT 5TH FLOOR, F-J/7 2ND LIFT 5TH FLOOR |
|
| 12/08/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: 5-7/B.7-C 2ND LIFT, F/2-4 2ND LIFT, G/2-4 2ND LIFT 5TH FLOOR |
|
| 12/07/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: A/4-7 2ND LIFT, 4/A-F 2ND LIFT, C/2-4, D/2-4 2ND LIFT 5TH FLOOR |
|
| 12/06/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/05/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL E/4-7, J/1-7 1ST LIFT 5TH FLOOR |
|
| 12/02/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/01/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) A/4-7, D/2-7, C/2-4, E/2-4, F/2-7 1ST LIFT 5TH FLOOR |
|
| 11/30/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: C-F/4-1ST LIFT 5TH FLLOR, 7/A-J 1ST LIFT 5TH FLOOR, STAIRWAY 1ST LIFT 5TH FLOOR |
|
| 11/29/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: 2/A-G 1ST LIFT 5TH FLOOR |
|
| 11/28/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 11/23/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: M.5/7-8 1ST LIFT 4TH FLOOR |
|
| 11/22/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: M.5-K/9-15 2ND LIFT 4TH FLOOR, 10-14/?-M 2ND LIFT 4TH FLOOR |
|
| 11/21/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL: 1-8/P 2ND LIFT 4TH FLOOR, 3/P-Q 2ND LIFT, 6/M.5-P.5 2ND LIFT, 8/M.3-P.3 2ND LIFT 4TH FLOOR | |
| 11/18/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*. 1) GL: P/1-2; P-Q/2, ?/1-9 ALL 2ND LIFT 4TH FLOOR |
|
| 11/17/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) M.-Q/4-15 1ST LIFT 4TH FLOOR, M-M.5/2-3 2ND LIFT 4TH FLOOR |
|
| 11/15/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M-N/2-3 1ST LIFT 4TH FLOOR, P/1-8 1ST LIFT 4TH FLOOR, Q/1-14 1ST LIFT 4TH FLOOR |
|
| 11/14/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 11/10/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALL AT 9' 4" GL: M/1-7 OK TO GROUT PROGRESS AREA (4TH FLOOR) |
|
| 11/09/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M/2-7 1ST LIFT 4TH FLOOR |
|
| 11/08/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 11/08/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL G-J/2-7 2ND LIFT 4TH FLOOR |
|
| 11/04/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 11/03/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: C-F/2-7 2ND LIFT 4TH FLOOR |
|
| 11/02/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL A-C/2-7 2ND LIFT 4TH FLOOR | |
| 11/01/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL H-K/2-7 1ST LIFT 4TH FLOOR |
|
| 10/31/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL C-G/2-7 1ST LIFT 4TH FLOOR |
|
| 10/28/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 7/A-E 1ST LIFT 4TH FLOOR, 2/A-G 1ST LIFT 4TH FLOOR, B/2-4 1ST LIFT, A/4-7 1ST LIFT 4TH FLOOR |
|
| 10/27/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 10/26/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL: 9-13/K 2ND LIFT 3RD FLOOR |
|
| 10/25/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 15/J-K 2ND LIFT 3RD FLOOR |
|
| 10/24/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STAIRWELL (C114) AT 9' 4", 3RD AFFE ALL WALLS; CMU WALLS AT 56" AFFE-3RD FLOOR; GL: 9/M-P; 11/M-P; 13/M-P OK TO GROUT PROGRESS AREAS |
|
| 10/21/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU EAST CORRIDOR WALL AT 9' 4" AFFE 3RD FLOOR; GL: P/1-8; CMU WALLS AT 9' 4" GL: 10/O-Q 12/O-Q; SOUTHEAST STAIRWELL (C114) SOUTH WALL-26' 4" AFFE. OK TO GROUT PROGRESS AREAS |
|
| 10/20/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALLS AT 9' 4" ABOVE 3RD F.F.E. GL: 1/P-Q, 3/P-Q, 6/P-Q; 8/P-Q; 3/M-O OK TO GROUT PROGRESS AREAS |
|
| 10/19/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) (C114) SOUTHEAST STAIRWELL AT 20' 4"; 3RD FLOOR CMU WALLS AT 56" AFFE; GL: Q/8-14; 10/O-Q; 12/O-Q; 14/O-Q; 6/O-Q OK TO GROUT PROGRESS AREAS |
|
| 10/18/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL P-4/1 1ST LIFT 3RD FLOOR, P/1-6 1ST LIFT 3RD FLOOR; P-M.5/1-8 1ST LIFT 3RD FLOOR |
|
| 10/17/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M-P/1 1ST LIFT 3RD FLOOR, 1ST FLOOR ELEVATOR SHAFT 3RD FLOOR AND P/1-2 1ST LIFT 3RD FLOOR |
|
| 10/13/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL J-M/2-7 2ND LIFT 3RD FLOOR |
|
| 10/12/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M/2-7 2ND LIFT 3RD FLOOR |
|
| 10/11/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT GL K/2-7 3RD FLOOR, GL J-K/4-7 2ND LIFT 3RD FLOOR |
|
| 10/10/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL C-F/4-7 2ND LIFT 3RD FLOOR, GL G./2-4 2ND LIFT 3RD FLOOR 2) AFTER HOURS INSPECTION PAID WITH CHECK #153 FOR $165.00 |
|
| 10/07/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL E/F/2-7 2ND LIFT 3RD FLOOR D-F/4 2ND LIFT 3RD FLOOR | |
| 10/06/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 10/05/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* G.L. B-F/2-7 1ST LIFT 3RD FLOOR |
|
| 10/03/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL A/2-7 1ST LIFT 3RD FLOOR |
|
| 10/02/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) GL 8-12/M-P 2ND LIFT 2ND FLOOR |
|
| 09/29/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 9-15/K 2ND LIFT 2ND FLOOR |
|
| 09/28/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 8/0 1ST LIFT AND 1/P-Q 2ND LIFT |
|
| 09/27/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 12-14-15/M-J 1ST LIFT 2ND FLOOR |
|
| 09/23/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GL P/38 1ST LIFT PROF 5-8 1ST LIFT 2ND FLOOR |
|
| 09/22/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT ON ELEVATOR SHAFT 2ND FLOOR; GL: 1/P-Q 1ST LIFT, 1-3/P 1ST LIFT ALSO 2ND FLOOR |
|
| 09/21/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL K-M/2-7 2ND LIFT ON 2ND FLOOR |
|
| 09/20/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL J/2-7 2ND LIFT 2ND FLOOR |
|
| 09/19/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL G-H/2-7 2ND LIFT 2ND FLOOR |
|
| 09/16/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) GL B-G/4-7 2ND LIFT 2ND FLOOR | |
| 09/15/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL H-J/2-4 2ND LIFT 2ND FLOOR, 2/H-J 2ND LIFT AND ?/H-J 2ND LIFT 2ND FLOOR |
|
| 09/13/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) 1ST LIFT 2ND FLOOR GL G-K/4-7 2) REMOVE WATER AWAY FROM BLDG |
|
| 09/13/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR GL A/2-7, 2ND LIFT C-D/2-4 2ND LIFT, GL M/2/7 1ST LIFT |
|
| 09/09/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND FLOOR: 1) INTERIOR WALLS AT 56" GL: D/4.5-7; H,J,K/2.4 OK TO GROUT PROGRESS AREAS |
|
| 09/08/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR: PATIO WALLS GL: 7/A-E; INTERIOR MASONRY WALLS GL: 4.5/A-E; E/4-5.7 NOTE: ENSURE M.C.J. IS CUT IN STAIRWELL WALL AT GL: C/4-7 (MISSED) |
|
| 09/07/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) PATIO OPENINGS GL 2/A-P; INTERIOR WALLS AT B-G, 2-4 AT 56" OK TO GROUT PROGRESS AREAS |
|
| 09/06/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
| 09/01/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT ELECTOR GLL/15/8 3RD LIFT |
|
| 08/31/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL P/1-8 3RD LIFT, 3/P-Q 3RD LIFT, 4/P-Q 3RD LIFT; 8/P-Q 3RD LIFT |
|
| 08/30/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL ?/J-M 2) 8' LIFT ON ELEVATOR |
|
| 08/29/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M-Q 7-12 8' LIFT |
|
| 08/26/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL N-6/7-? 4' LIFT, Q/1-12 4' LIFT |
|
| 08/25/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* G.L. P-Q/1 4' LIFT, P-Q/3 4' LIFT, M.C.-Q/6 4' LIFT M-D/1 4' LIFT |
|
| 08/24/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* K-M/1.8-7 3RD LIFT, J-M-5/14-15 1ST LIFT |
|
| 08/23/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR 2ND LIFT 12' LIFT G-K K-M 1-6.5 12' LIFT |
|
| 08/22/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GL J-M 2ND LIFT, K 1-6 2ND LIFT, M1-6 1ST LIFT | |
| 08/19/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GL J/2.7 4' LIFT |
|
| 08/18/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL C-D/4-7 12' LIFT, J/2-4 4' LIFT |
|
| 08/17/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL M/4-7 1ST LIFT, C/4-7 12' LIFT, E & F/4-7 12' LIFT |
|
| 08/16/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL C/4.5-7 8' LIFT AND G-J/1 4' LIFT |
|
| 08/15/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH WING: GL: 2/A-G AT 12' 8"; INTERIOR WALLS AT GL 4-7 AT 12' OK TO GROUT PROGRESS AREAS |
|
| 08/11/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 1ST LIFT C-D/4-7, G/4-7 2ND LIFT 4-7(A-C.5 2ND LIFT |
|
| 08/10/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT E-F/R, E-6/2-4 F/2-7, E/4-7 1ST LIFT |
|
| 08/09/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT GL A/2-7, 4/A-D, C/2-4 AND D/2-4 |
|
| 08/05/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT C-F/2-4 |
|
| 07/26/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4' LIFT GL Q/1-15 B-5/2 |
|
| 07/15/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEM AT GL 3-6/P, 4TH LIFT AT ELEVATOR PIT |
|
| 07/14/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 07/13/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEM AT GL 15-8/K-M, K-M/1-6 OK |
|
| 07/12/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT ON ELEVATOR SHAFT |
|
| 07/11/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEM AT GL A-F/2-7 |
|
| 07/07/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 3-14/P |