Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T11CM00617
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2012 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/26/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 06/21/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 06/20/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - OK 5TH FLOOR - FIRE PUMP FEEDER - OK ENTRY SIDEWALK LTG SOUTH SIDE |
|
| 06/18/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SOUND SYSEM WIRING TO BE SUPPORTED PER CODE & SPEAKERS TO HAVE SISMEC SUPPORT TO STRUCTURE. MUST USE OWN SUPPORT WIRES DISC SW. FOR AIR HANDER IN VIOLATION 110.26 NEC J-BOXS FOR FEEDERS COVERS NEED TO ALLOW ACCESS |
|
| 05/14/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 05/11/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 05/10/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CONTRACTOR TO LOCK OUT/TAG OUT 2) OK ROUGH IN PLANTERS |
|
| 05/09/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CONTRACTOR TO LOCK OUT/TAG OUT |
|
| 04/25/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR WEIGHT ROOM WALLS AND 3RD FLOOR LAUNDRY 2) 5TH FLOOR ENTRY SOFFITS |
|
| 04/18/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 04/17/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 4TH FLOOR SOFFITS/HARD LIDS |
|
| 04/13/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK ROOMS #603 & 605 |
|
| 04/11/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 1ST FLOOR ROUGH, EXCEPT GRID 2) OK WALLS 1ST FLOOR |
|
| 04/09/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK ROOMS #505, 507 AND SOFFITS 3RD FLOOR LAUNDRY 2) OK 3RD FLOOR ROUGH-GRID CEILING LEFT |
|
| 04/05/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK #405 & 407 |
|
| 04/03/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK ROOMS 305 & 307 |
|
| 03/28/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK ENTRY SOFFITS LTG. |
|
| 03/23/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 5TH OK ROOM #519 & 520-STILL NEED LAUNDRY AND SOFFITS |
|
| 03/22/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) IOK 205 AND 207 WALLS/HARD LIDS |
|
| 03/20/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK WALLS EXCEPT ROOMS 605, 603 AND PATIO AREA 2) OK HARD LIDS |
|
| 03/08/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 3, 4 & 5TH FLOOR MAIN CORRIDOR WALLS |
|
| 03/06/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK WALLS EXCEPT, LAUNDRY 205, 207, 505, 507, EXTERIOR WALLS |
|
| 02/22/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 1ST FLOOR CORRIDOR WALLS |
|
| 02/10/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 4TH FLOOR: CK VERTICAL RISER |
|
| 01/27/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 3RD FLOOR WALLS AND CEILINGS OK |
|
| 01/25/2012 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK 2ND FLOOR EXCEPT #205 AND 207-EXTERIOR WALL. WALLS AND HARDLIDS |
|
| 11/30/2011 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 1ST FLOOR UNITS 101 THRU 119 |
|
| 11/18/2011 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 11/10/2011 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PROTECT M/C INSIDE OF STUD CHANNEL 2) SECURE M/C WITHIN 12" OF FITTINGS AND 6' 3) CHECK PLAN FOR COUNTER TOP RECEPT AND 210.52 |
|
| 11/07/2011 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |