Permit: T09CM01368
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
11221 E NEBRASKA RD
Address NEW:
11221 E NEBRASKA RD
Apply Date:
05/29/2009
Applicant:
N/A
Description:
NEW SFR
Permit Reviews
Permit Number - T09CM01368
Permit Status: C of o
Permit Description: NEW SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/08/2010 | RESUBMITTAL | 01/29/2010 | COMPLETED |
| 01/14/2011 | REVISION - - 1ST | 01/19/2011 | COMPLETED |
| 01/19/2011 | REVISION - - 2ND | 01/20/2011 | COMPLETED |
| 01/29/2010 | RESUBMITTAL | 01/29/2010 | COMPLETED |
| 05/29/2009 | PLANS OK TO SUBMIT - RES | 06/02/2009 | COMPLETED |
| 06/02/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 07/02/2009 | COMPLETED |
| 07/08/2011 | REVISION - - 3RD | 07/08/2011 | COMPLETED |
| 08/25/2009 | RESUBMITTAL | 09/15/2009 | COMPLETED |
| 09/15/2009 | RESUBMITTAL | 10/05/2009 | COMPLETED |
| 10/13/2009 | RESUBMITTAL | 10/26/2009 | COMPLETED |
| 12/15/2009 | RESUBMITTAL | 01/05/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM01368
Permit Status: C of o
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/29/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T09CM01368
Permit Description: NEW SFR
Total Completed Inspections - 32
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2010 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/21/2010 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
| 05/25/2010 | STEM WALL/RETAINING WALL | RFREIDIN | Approved | 1) PLEASE LEAVE COPY OF CERTIFIED PAD HEIGHT. NOTED AS #11 ON THE FRONT PAGE OF PLAN, IF YOU HAVE IT FINE CONTINUE, IF NOT DON'T GO ANY FURTHER WITHOUT IT |
| 06/03/2010 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* 1) FROM LAST INSPECTION SEE 2ND PAGE OF PLAN 2) I NEED THE PAD ELEVATION CERT., IF YOU DON'T HAVE DON'T GO ANY FURTHER |
| 06/22/2010 | REINFORCED MASONRY PRE-GROUT | RFREIDIN | Approved | IVRS - Inspection :* 1) LOOKED AT PAPERWORK REF., WELDING, I ASSUME IT WAS FOR VERT. BARS ATTACHED TO GARAGE I BEAM HEADER-PLEASE TAKE THAT INFO, ALSO WITH A DETAIL OF CROSS SECTION SHOWING GABLE END, COMPLETE WITH I BEAM, WITH SIZE OF BEAM AND AS ONLY SUPPORT FOR OPENING |
| 08/10/2010 | ELECTRIC - TEMPORARY SERVICE | DQUINN | Approved | IVRS - Inspection :* |
| 08/10/2010 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection :* |
| 08/11/2010 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER D. QUINN |
| 08/24/2010 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* 1) POST FOOTING AT OUTSIDE PORCH NORTH, SOUTH AND WEST SIDES AND SLAB AT SAME OK |
| 09/17/2010 | FRAMING | WLAHR | Approved | |
| 09/17/2010 | EXT METAL CLIPS/EXT SHEATHING | WLAHR | Approved | 1) POST TO BEAM CONNECTOR AND PLANS CALLS FOR PC88 2) UNABLE TO GET ONTO ROOF 3) CALL IN FRAMING WHEN COMPLETED WITH ELECTRIC, PLUMBING AND MECHANICAL INTERMEDIATES |
| 09/22/2010 | ROOF NAILING | DWALKER | Approved | 1) OK TO COVER ROOF-NEED APPROVED TRUSS DRAWINGS ON SITE FOR REVIEW |
| 11/19/2010 | MECHANICAL - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection : See detailed listing on site.| 999* BLOCK REGISTERS MIN 3 SIDES |
| 12/13/2010 | ELECTRIC - INTERMEDIATE | WLAHR | Approved | 1) NOTE: SUPPORT 4 GANG BOXES |
| 12/30/2010 | PLUMBING - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) TRAPS NEEDED AT BATH TUBS, WATER TEST NEEDED ON ALL DWV 2) OVER FILL OF CONDUCTORS IN BOXES AND UNSUPPORTED 4 GANG BOXES |
| 01/21/2011 | U VALUE FOR WINDOW | WLAHR | Approved | IVRS - Inspection :* |
| 02/14/2011 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* |
| 05/18/2011 | PLUMBING - GAS PRESSURE TEST | WLAHR | Approved | IVRS - Inspection :* |
| 06/30/2011 | FIRE SPKLR - FINAL | WMOTTO | Approved | |
| 07/01/2011 | NPPO - FINAL | DROBERTS | Approved | NO NPPO ITEMS NOTED ON THE PLANS, NO GRADING PERMIT NOTED BEING APPROVED FOR THIS SITE. |
| 07/01/2011 | NPPO PRE PERMIT INSPECTION | DROBERTS | Approved | NO NPPO ITEMS NOTED ON THE APPROVED PLANS FOR THIS SITE. |
| 07/12/2011 | PLUMBING - SEWER HCS CONNECT | WLAHR | Approved | |
| 07/12/2011 | PLUMBING - GAS PRESS TEST FNL | WLAHR | Approved | IVRS - Inspection :* |
| 07/12/2011 | PLUMBING - YARD WTR LINE/TEST | WLAHR | Approved | IVRS - Inspection :* |
| 07/12/2011 | MECHANICAL - FINAL | WLAHR | Approved | IVRS - Inspection :* |
| 07/12/2011 | PLUMBING - FINAL | WLAHR | Approved | IVRS - Inspection :* |
| 07/12/2011 | ELECTRIC - FINAL | WLAHR | Approved | IVRS - Inspection :* |
| 07/12/2011 | BUILDING - FINAL | WLAHR | Approved | IVRS - Inspection :* |
| 07/12/2011 | ZONING - FINAL | DROBERTS | Approved | |
| 07/12/2011 | ENGINEERING PRE-CONSTRUCTION | DROBERTS | Approved | |
| 07/12/2011 | LANDSCAPE INSPECTION | DROBERTS | Approved | |
| 07/10/2013 | FLOODPLAIN INSP | GBONILLA | Approved | PER 9150 FINAL |