Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09CM01368
Parcel: 20566099C

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T09CM01368
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2009 SEPTIC APPROVAL WWM REVIEW Denied need septic design submitted to P C building codes for review & approval
06/09/2009 ANDREW CONNOR NPPO REVIEW Needs Review Needs to be reviewed when returned!
06/10/2009 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T09CM01368
11221 East Nebraska Road
New SFR


TRANSMITTAL: June 12, 2009


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) This review is for a new single-family residence (SFR) in the SR Zone (LUC Section 2.2.4.2.A.1). Provide the correct zoning on the plot plan, in the site data information and on all the adjacent lots. The Development Designator is "C" (LUC Section 3.2.3.1.A) and the Perimeter Yard Indicator is BB (LUC Section 3.2.6.4). This site is subject to LUC Section 3.5.7.1.F.

2) It appears that the resent lot split (12-07-2005) has not been review and approved by the City of Tucson as required (LUC Sections 4.3.1, 4.3.2 & 4.3.3). In addition, two of the three parcels do not meet the minimum lot size requirements for the SR Zone (LUC Section 3.2.14). The minimum parcel size in the SR Zone is one hundred forty-four thousand (144,000) square feet (approximately 3.30 AC) (LUC Sections 2.2.4.A.1 & 3.2.3.1.A). Parcel 205-66-099D is listed as 2.04 AC, which is approximately eighty eight thousand eight hundred sixty two (88,862) square feet, by the Pima County Assessor. Parcel 205-66-099E is listed as eleven thousand seven hundred twenty (11,720) square feet, or approximately 0.27 AC. An approved lot split shall be required to proceed with an further development on this site.

3) Demonstrate minimum legal access to all proposed lots (LUC Sections 4.3.1, 4.3.3.B.7, 4.2.14.5.A, & .B, 3.2.8.2, 3.2.8.3).

4) There appears to be a SFR on the site according to the records with the Pima County Assessor and the aerial photos. The maximum number of units in the SR Zone is one (1) (LUC Sections 2.2.4.2.A.1 and 3.2.3.1.A). Provide a demo permit for the existing SFR.

5) The property lines on the plot plan are incomplete. Provide the correct property lines with dimensions on the plot plan. Also place dimension of the proposed structure and any existing structures to remain from the nearest edge of each structure to each property line (LUC Section 3.2.6.4).

6) Revise the legal description to match the legal description provide by the County.

7) The minimum type size is twelve point (12 pt) for all text and dimensions.

Please be aware that there may be additional comments relative to information provided on subsequent submittals.
06/17/2009 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 06/18/2009,

Drainage Report:

1. It is not clear which offsite watershed that actually impacts the proposed development. Is it the 42.75 acres, the 43.78 acres or the 52.68 acres?
2. What dos the cross hatched areas, shown on the drainage exhibits, represent? Provide a description for the cross hatch in the legend.
3. Show on the drainage exhibits the proposed structures, the proposed finished floor elevation, the proposed grading around the structure and through out the parcel, the proposed structure access, etc. Please be advised that the structure shall be provided with an all weather access. Access through the erosion setback area is not considered all weather access.
4. According to Section 8.4. of the Drainage Manual, "No Building shall be built within the erosion-hazard setback limit associated with the main channel, unless adequate bank protection is first installed". Determine the erosion setback line from the onsite tributary to the Pantano and show the setback line on the drainage exhibits. Show the proposed structure outside all erosion-hazard limits. Additionally, if the structure is located within a sheet flow of the regulatory floodplain, as stated in the "Erosion Hazard Setback" Section of the Report, the structure shall be built on a fill that extends at least 25' on all sides of the building (see Section 8.4 of the Drainage Manual).
5. Determine the minimum finished floor elevation for the proposed structure (i.e. 28xx.xx feet).
6. The proposed corral needs to be shown on the drainage exhibit. Verify that the corral will not be obstructing the onsite wash runoffs.

Site Plan:

1. Provide property description (D.S. 2-02.1.2.).
2. Provide lot dimensions and bearings (D.S. 2-02.1.5.).
3. Show all existing buildings and structures as required by D.S. 2-02.1.6.
4. Provide width of driveway as required by D.S. 2-02.1.11. Additionally, the driveway can not be within the erosion-hazard area. Relocate the driveway to provide all weather access.
5. Provide the 100-year floodplain water surface elevations as required by D.S. 2-02.1.15.
6. The shown finish floor elevation for the proposed building appears to be incorrect. Revise the proposed building finished floor elevation in accordance with the Drainage Report recommendation D.S. 2-02.1.16.
7. Provide the proposed finish grades as required by D.S. 2-02.1.16.
8. Provide the estimated cut and fill (D.S. 2-02.1.17.).
9. It is not clear if Nebraska Road is an access easement or public right of way. Add the width and the recordation information if the street is an easement or dimension the right of way if Nebraska is public (D.S. 2-02.1.19.).
10. Show all easements of record, if applicable, as required by D.S. 2-02.1.20.
11. The Site Plan needs to be stamped by a registered civil engineer.
12. Clarify how the cut/fill slopes will be treated and or stabilized. Provide a geotechnical report addressing slope treatment/stabilization.
06/26/2009 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 6-29-09
Activity: T09CM01368
Address: 11221 E. Nebraska
Applicant: Troy Williams

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

2. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. All plan pages should reference this code. Appeal to the Building Official for alternate code use. (Ref: pages 2, 5, 10)

FLOOR PLANS:
3. Specify width of all doors on floor plan (closets, toilet rooms, and utility room).
4. Specify safety glazing in hazardous locations, R308.4. Less than 60" above tub/shower floors.
5. Specify finished floor elevation of porch areas and designate the accessible route for the Inclusive Home Design Ordinance.
6. Show fireplace hearth size and materials, R1001 or R1004. Provide fireplace cut sheets or note the requirement for deferred submittal approval prior to installation.
7. Show the location of attic access min. 22"x30", R807.

STRUCTURAL PLANS:
8. Clarify keynotes and keynote references on page 7.
9. Justify the lintel schedule for the proposed design.

SECTIONS - DETAILS:
10. Provide accurate cross references for section view drawings.
11. Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d.
12. Specify insulation R-value for stud wall cavities.
13. Specify gable-end bracing with connections to the structure, R802.10.3.
14. Specify exterior wall covering for gable ends. Specify thermal barrier protection from rigid foam on gable ends per R314.5.3 if stucco is to be applied.

PLUMBING PLAN:
15. Show the size and location of all cleanouts, P3005.2. Cleanouts are required at the kitchen sink area UPC 707.4 W/ State amendment.
16. Specify the size of the required vent through roof at the master bathroom branch group, P3101.1.

MECHANICAL PLAN:
17. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. (Note provided specifies that ductwork in unconditioned spaced to be insulated with R-5)
18. Show the condensate line and secondary for HVAC units, M1411.3.
19. Flues connected to more than one appliance shall be not less than the area of the largest connector plus 50% of the additional connectors. Water heater typical - 3" flue. Furnace - 4" flue. IRC M1805.3.
20. Show dryer vent size and location for venting to exterior (max 25' w/bend reductions), M1502.2, M1502.6.

ELECTRICAL PLAN:
21. Use Table E3602.13 for sizing 15, 20 & 30 AMP branch circuit conductors. Use Table E3605.1 (60 degree C column) for sizing branch circuits and conductors rated <100 amps.
22. Justify the 40amp over current protection for the range circuit with a proposed load of 13,500 watts.
23. Bedroom outlets shall be protected with combination-type arc-fault breakers (receptacles, lights, and smoke detectors), E3802.12. (Ref: circuits 19, 21, 26)
24. GFCI protection required for receptacles in garages, E3802.
25. Receptacles shall not be located below a counter where the countertop extends more than 6" beyond its support base, E3801.4.5. Island or peninsula counter tops with a long dimension of 24" and a short dimension of 12" or greater shall have at least one receptacle, E3801.4.2.
26. Exterior outlets at grade level shall be provided at both the front and back of the dwelling, E3801.7. These outlets shall be GFCI protected E3802.3.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review
06/30/2009 DAVE MANN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/02/2009 CPIERCE1 OUT TO CUSTOMER Completed
07/02/2009 SUE REEVES REJECT SHELF Completed