Permit: T08CM00189
Permit Details
Apply Date:
01/18/2008
Applicant:
N/A
Description:
TI:OFFICE/CHANGE OF USE
Contractors:
- KRAUS ANDERSON CONSTRUCTION COMP
Permit Reviews
Permit Number - T08CM00189
Permit Status: C of o
Permit Description: TI:OFFICE/CHANGE OF USE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/18/2008 | PLANS OK TO SUBMIT - COMM | 01/18/2008 | COMPLETED |
01/18/2008 | COMMERCIAL TI | 02/28/2008 | COMPLETED |
02/28/2008 | RESUBMITTAL | 03/18/2008 | COMPLETED |
03/18/2008 | RESUBMITTAL | 03/18/2008 | COMPLETED |
03/18/2008 | RESUBMITTAL | 04/08/2008 | COMPLETED |
04/08/2008 | RESUBMITTAL | 04/08/2008 | COMPLETED |
04/08/2008 | RESUBMITTAL | 04/18/2008 | COMPLETED |
04/18/2008 | RESUBMITTAL | 04/29/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM00189
Permit Status: C of o
Permit Description: TI:OFFICE/CHANGE OF USE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/18/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM00189
Permit Description: TI:OFFICE/CHANGE OF USE
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2008 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
05/16/2008 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* WATER TEST THRU HCS TO EXISTING SEWER OK |
06/12/2008 | FRAMING | GDABBS | Approved | IVRS - Inspection :* HARD LID FRAMING @ LOBBY & CORRIDORS |
07/08/2008 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* 1. PROVIDE A SECONDARY DRAIN PAN UNDER FAN COIL 2. SUPPORT DRAIN LINE FROM CONDENSATE PUMP 3. SECONDARY DRAIN TO BE TERMINATED TO A CONSPICUOUS LOCATION. 4. OK FOR CEILING TILES 5. LEAVE OUT AROUND FAN COIL |
07/16/2008 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* NOTE: HOSE BIB CANNOT BE LOCATED IN CLEAR SPACE OF ELECTRICAL DISCONNECT |
07/21/2008 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
07/22/2008 | RIGHT OF WAY - FINAL | MCASTRO | Approved | |
07/22/2008 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILES |
07/23/2008 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* RECEIVED BACTERIA REPORT FOR POTABLE WATER |
07/23/2008 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
07/23/2008 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
07/24/2008 | SIGN - FINAL | JYBARRA | Approved | PERMITS ISSUED FOR WINDOW DECALS; OK FOR C/O |
07/24/2008 | SIGN - FINAL | JYBARRA | Approved | STILL NEED TO PERMIT OR REMOVE WINDOW DECALS; SPOKE W/ MARK FROM FLUORESCO AND THEY ARE WORKING ON OBTAINING PERMITS FOR WINDOW SIGNS |
07/25/2008 | MECHANICAL - FINAL | JMILITEL | Approved | OK FOR FINAL |
07/25/2008 | ELECTRIC - ABOVE CEILING | LHANLY | Approved | |
07/25/2008 | ELECTRIC - INTERMEDIATE | LHANLY | Approved | |
07/25/2008 | BUILDING - PROGRESS | LHANLY | Approved | |
07/25/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | |
07/28/2008 | NPPO - FINAL | ACONNOR | Approved | |
07/28/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
08/12/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* SMOKE WALL HAS BEEN INSTALLED AND APPROVED BY FIRE DEPT |
08/12/2008 | SHEET ROCK NAILING | GDABBS | Approved | |
08/12/2008 | ENGINEERING - FINAL | NKALAHAR | Approved | -TEMP ASPHALT PATCH NEEDS TO BE ADDRESSED (PER SITE SUPER THIS IS NOT A TENANT RESPONSIBILITY-LANDLORD CONTACTED) CP-SWEEPER TO BE RUN THROUGH PARKING LOT CP-SOME CLEAN UP STILL LEFT TO CP |
08/12/2008 | FIRE - FINAL | CSCHULTZ | Approved | as approved by D. Mann |