Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM00189
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/23/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
06/10/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV THRU ROOF TEST OK WATER TEST OK 1. NEED TO SEE CONTINUATION OF 2" WATER ON EXTERIOR |
|
06/09/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* THERE IS NO FALL OR SUPPORT ON PIPING FROM DOUBLE ELL LEFT A HANDOUT PER 2006 UPC ILLUSTRATED TRAINING MANUAL. MAKE CORRECTION. |
|
06/06/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER DISTRIBUTION IS OK DWV TEST THRU ROOF PARTIAL APPROVAL 1. PROVIDE LISTING FOR 4" DOUBLE ELL TO BE USED AS DRAINAGE FITTING. RETEST CARRIERS WITH SPUD NIPPLES INSTALLED SUPPORT PIPING IN CARRIER AREA |