Permit: T07CM04543
Permit Details
Apply Date:
12/05/2007
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:HEALTH CENTER
Architects:
- MASCIA, FRANK
Contractors:
- KNOTHOLE CREATIONS L L C
Permit Reviews
Permit Number - T07CM04543
Permit Status: C of o
Permit Description: TI:HEALTH CENTER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/04/2008 | POST 3RD PARTY REVIEW | 02/13/2008 | COMPLETED |
| 12/05/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 12/12/2007 | COMPLETED |
| 12/12/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 02/04/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM04543
Permit Status: C of o
Permit Description: TI:HEALTH CENTER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/05/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM04543
Permit Description: TI:HEALTH CENTER
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2008 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* YOU WILL NEED TO REMOVE AND PLUG ABANDON PIPE PENTRATIONS THRU SLAB AND ROOF |
| 03/21/2008 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/25/2008 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* - FLEX DUCTS & HANGER STRAPS NOT INSTALLED PER PLAN SEE DETAIL M2.0 - SOME DIFFUSERS MISSING OBD FOR BALANCING - REPLACE DAMAGED SUPPLY DUCT - OK TO SHEETROCK SOFFITS - SEAL SPOT WELDS & SEAMS ON NEW DUCT ON ROOF - SUPPORT GAS LINES - REMOVE GAS FLEX FROM SW UNIT - PROVIDE CONDENSATE DRAINS AS NEEDED - RESUPPORT CONDENSATE DRAINS - PROVIDE TRAPS AS NEEDED - PROVIDE FRESH AIR INTAKES AS NEEDED - GAS FLEX CANNOT PENETRATE THE CABINET OF A FURNACE - RESUPPORT ELEC. CONDUITS - PROVIDE SERVICE RECEPTACLES ON ROOF AS REQUIRED BY NEC |
| 03/28/2008 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE THROUGHOUT |
| 04/02/2008 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
| 04/02/2008 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 04/16/2008 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILES |
| 04/23/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 04/25/2008 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
| 04/29/2008 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/29/2008 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/29/2008 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/29/2008 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
| 04/29/2008 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* |
| 05/01/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* PENDING FIRE FINAL -- ALL TRADES ARE COMPLETE |
| 05/01/2008 | FIRE SPKLR - FINAL | CSCHULTZ | Approved | |
| 05/01/2008 | FIRE - FINAL | CSCHULTZ | Approved | |
| 05/01/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 05/01/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 05/02/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 05/02/2008 | NPPO - FINAL | JLINVILL | Approved | |
| 05/02/2008 | LANDSCAPE - FINAL | JLINVILL | Approved | |
| 05/02/2008 | ENGINEERING - FINAL | NKALAHAR | Approved | NO SITE WORK PER PLAN REMINDED CONTRACTOR TO FINISH ALL CLEAN UP INCLUDING PAINT CANS AT N SIDE OF BUILDING |
| 05/02/2008 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 05/05/2008 | PERMIT FINALED | BFLORES | Approved |