Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM04543
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/21/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - I FOUND THE LETTER APPROVING PEX, WHAT ABOUT THE APPROVAL FOR THE ZIPSTICKS - THEY ALREADY CHANGED THE HANGERS - ABS THRU THE ROOF OK - NEED TO SEE THE PEX SUPPORTED AFTER INSULATION |
|
| 03/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. WILL REQUIRE A STAMPED LETTER ALLOWING PEX IN LIEU OF COPPER 2. ONLY ONE THIRD OF THE TOTAL DEVELOPED LENGTH MAY BE RUN IN THE HORIZONTAL POSITION 3. NAIL GUARDS 4. INSULATE HOT PIPING 5. HARD CAP DEMO'D PIPING 6. WILL REQUIRE LETTER ALLOWING "ZIP STICKS" IN LIEU OF HANGERS |