Permit: T07CM04543

Parcel: 12302288A


Addresses:

2501 E ELM ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
03/25/2008 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
- FLEX DUCTS & HANGER STRAPS NOT INSTALLED PER PLAN
SEE DETAIL M2.0
- SOME DIFFUSERS MISSING OBD FOR BALANCING
- REPLACE DAMAGED SUPPLY DUCT
- OK TO SHEETROCK SOFFITS
- SEAL SPOT WELDS & SEAMS ON NEW DUCT ON ROOF
- SUPPORT GAS LINES
- REMOVE GAS FLEX FROM SW UNIT
- PROVIDE CONDENSATE DRAINS AS NEEDED
- RESUPPORT CONDENSATE DRAINS
- PROVIDE TRAPS AS NEEDED
- PROVIDE FRESH AIR INTAKES AS NEEDED
- GAS FLEX CANNOT PENETRATE THE CABINET OF A FURNACE
- RESUPPORT ELEC. CONDUITS
- PROVIDE SERVICE RECEPTACLES ON ROOF AS
REQUIRED BY NEC