Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04543
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/01/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/29/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CLEANOUTS IN DRIVEWAY TO BE MADE TRAFFIC RATED 2. FINISH INSULATION AT WATER HEATER 3. ADD CLIPS TO THE SINKS 4. CHECK CLEAN OUT SCREWS 5. CLEAN BACTERIA REPORT |
|
| 04/25/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CLEAN BACTERIA REPORT PER UPC 2006 609.9 2. PROVIDE THERMOSTAT MIXING VALVE AT LAVS 3. PROVIDE WATER HAMMER ARRESTOR FOR EXISTING URINAL 4. PROVIDE LISTING FOR CLEANOUTS IN DRIVEWAY 5. LIST MAY NOT BE COMPLETE |