Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Apply Date:
01/04/2007
Applicant:
INTERTECH
Description:
NEW BANKING FACILITY
Architects:
  • SWAN WAYNE E
Contractors:
  • WOODBURN CONSTRUCTION CO

Permit Reviews

Permit Number - T07CM00069
Permit Status: C of o
Permit Description: NEW BANKING FACILITY
Start Date Submittal Complete Date Status  
01/04/2007 PLANS OK TO SUBMIT - 3RD PARTY 01/05/2007 COMPLETED Review Details
01/05/2007 3RD PARTY REVIEW-COMMERCIAL 02/16/2007 COMPLETED Review Details
02/16/2007 POST 3RD PARTY REVIEW 06/20/2007 COMPLETED Review Details
04/11/2007 SITE 06/20/2007 COMPLETED Review Details
07/19/2007 RESUBMITTAL - SITE ALL 08/21/2007 COMPLETED Review Details
07/19/2007 RESUBMITTAL 08/21/2007 COMPLETED Review Details
08/29/2007 RESUBMITTAL 09/14/2007 COMPLETED Review Details
08/29/2007 RESUBMITTAL - SITE ALL 09/13/2007 COMPLETED Review Details
09/11/2007 RESUBMITTAL - SITE 09/14/2007 COMPLETED Review Details
09/14/2007 RESUBMITTAL 10/29/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM00069
Permit Status: C of o
Permit Description: NEW BANKING FACILITY
Total Outstanding Activity Conditions - 1
Date Name
01/04/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM00069
Permit Description: NEW BANKING FACILITY
Total Completed Inspections - 35
Date Description Inspector Results Comments
11/14/2007 PLUMBING - ROUGH, SOIL BBENEDON Approved
11/14/2007 ELECTRIC - UFER RJIROUDE Approved IVRS - Inspection :*
1/0 COPPER MORE THAN 20' IN FOOTING
11/14/2007 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
USE TAPE TO HOLD WRAPS IN PLACE
WRAPS MUST BE VISIBLE AFTER CONCRETE
11/14/2007 EXCAVATION/LAYOUT REBAR & ZON GDABBS Approved IVRS - Inspection :*
1. 7 PIER FOOTINGS AS PER DETAIL S1.0/102 & 102A 4 ON SOUTH & 3 ON NORTH
2. 100 L.F FOOTING FOR WEST SCREEN WALL
11/14/2007 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
11/29/2007 STEM WALL/RETAINING WALL GDABBS Approved IVRS - Inspection :*
12/06/2007 REINFORCED MASONRY PRE-GROUT GDABBS Approved IVRS - Inspection :*
DUMPSTER ENCLOSURE AND 40" SITE WALL AT N/W CORNER OF SITE
12/10/2007 FRAMING GDABBS Approved IVRS - Inspection :*
12/10/2007 ROOF NAILING GDABBS Approved IVRS - Inspection :*
12/12/2007 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
12/13/2007 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
DWV WATER TEST THRU ROOF OK
WATER PIPING THRU BUILDING FROM STUB TO EXTERIOR OK

1. SHALL INSPECT CORRECT CLOSET FLANGE CORRECTLY
12/18/2007 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :*
1. OK WALLS
2. OK 2 1/2" PVC FROM TEP PULL BOX TO SES
3. OK 3/4" PVC FOR WALL LIGHT
4. OK 3/4" PVC FOR BALLARD LIGHT FROM BUILDING TO 1ST LIGHT
5. PROVIDE LETTER FROM ENGINEERING APPROVING CHANGE IN PVC SIZE
6. INSTALL WARNING RIBBON ABOVE SERVICE CONDUCTORS PER NEC 300.5
12/18/2007 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
12/19/2007 STUCCO MESH GDABBS Approved IVRS - Inspection :*
12/20/2007 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
01/18/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
- FLEX DUCTS NOT INSTALLED PER DETAILS ON PLANS
- USE ONLY UL LISTED DUCT TAPE AS PER IMC
- PROVIDE OVERFLOW SENSORS AS PER PLAN
- PROVIDE BUSHINGS AROUND REFER LINE CONNECTIONS TO FAN COIL
- READJUST SUPPORTS ON FC-1 BLOCKING SERVICE PANEL
- SECURE SUPPORTS TO STRUCTURE
- FINISH INSULATING REFER LINES
- T-STATS TO BE ADA HEIGHT 48" MAX
- REVISE PLANS SHOWING PROPER LOCATION OF CONDENSORS
01/24/2008 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
01/31/2008 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
02/08/2008 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
02/13/2008 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
02/20/2008 SIGN - FINAL JSONKIN Approved
02/21/2008 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
TEMPERED GLASS SYSTEM
02/21/2008 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
02/22/2008 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
02/26/2008 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RECEIVED CLEAN BACTERIA REPORT FOR POTABLE WATER SYSTEM
05/19/2008 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
05/19/2008 OUTDOOR LIGHTING FINAL RJIROUDE Approved IVRS - Inspection :*
05/19/2008 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved IVRS - Inspection :*
05/19/2008 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
05/19/2008 ELECTRIC - CABLE DROP RJIROUDE Approved IVRS - Inspection :*
05/19/2008 FIRE - FINAL LTHOMAS Approved
08/14/2008 LANDSCAPE - FINAL ACONNOR Approved
08/28/2008 ENGINEERING - FINAL NKALAHAR Approved PER N KALAHAR - SITE NOW MATCHES STAMPED PLAN PROVIDED BY PATRICIA GEHLEN
09/02/2008 PERMIT FINALED NKALAHAR Approved
09/16/2008 BUILDING - FINAL LHANLY Approved

Documents

File Name Document Type  
C OF O_09-16-2008.TIF CERT OF OCC VIEW
TEMP C OF O_02-27-2008.TIF CERT OF OCC VIEW
T07CM00069_001.TIF CONSTRPLANS VIEW
T07CM00069_002.TIF CONSTRPLANS VIEW
T07CM00069_003.TIF CONSTRPLANS VIEW
T07CM00069_004.TIF CONSTRPLANS VIEW
T07CM00069_005.TIF CONSTRPLANS VIEW
T07CM00069_006.TIF CONSTRPLANS VIEW
T07CM00069_007.TIF CONSTRPLANS VIEW
T07CM00069_008.TIF CONSTRPLANS VIEW
T07CM00069_009.TIF CONSTRPLANS VIEW
T07CM00069_010.TIF CONSTRPLANS VIEW
T07CM00069_011.TIF CONSTRPLANS VIEW
T07CM00069_012.TIF CONSTRPLANS VIEW
T07CM00069_013.TIF CONSTRPLANS VIEW
T07CM00069_014.TIF CONSTRPLANS VIEW
T07CM00069_015.TIF CONSTRPLANS VIEW
T07CM00069_016.TIF CONSTRPLANS VIEW
T07CM00069_017.TIF CONSTRPLANS VIEW
T07CM00069_018.TIF CONSTRPLANS VIEW
T07CM00069_019.TIF CONSTRPLANS VIEW
T07CM00069_020.TIF CONSTRPLANS VIEW
T07CM00069_021.TIF CONSTRPLANS VIEW
T07CM00069_022.TIF CONSTRPLANS VIEW
T07CM00069_023.TIF CONSTRPLANS VIEW
T07CM00069_024.TIF CONSTRPLANS VIEW
T07CM00069_025.TIF CONSTRPLANS VIEW
T07CM00069_026.TIF CONSTRPLANS VIEW
T07CM00069_027.TIF CONSTRPLANS VIEW
T07CM00069_028.TIF CONSTRPLANS VIEW
T07CM00069_029.TIF CONSTRPLANS VIEW
T07CM00069_030.TIF CONSTRPLANS VIEW
T07CM00069_031.TIF CONSTRPLANS VIEW
T07CM00069_032.TIF CONSTRPLANS VIEW
T07CM00069_033.TIF CONSTRPLANS VIEW
T07CM00069_034.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW