Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Address NEW:
7040 E BROADWAY BL
Apply Date:
09/01/2006
Applicant:
N/A
Description:
TI: RESTAURANT R1-revision of mechanical,plumbing, & electrcial
Contractors:
  • SHANNON CONSTRUCTION LLC

Permit Reviews

Permit Number - T06CM04878
Permit Status: Final
Permit Description: TI: RESTAURANT R1-revision of mechanical,plumbing, & electrcial
Start Date Submittal Complete Date Status  
07/30/2007 3RD PARTY REVIEW-REVISION/OTHER 07/31/2007 COMPLETED Review Details
09/01/2006 COMMERCIAL TI 09/01/2006 COMPLETED Review Details
09/01/2006 3RD PARTY REVIEW-COMMERCIAL TI 11/09/2006 COMPLETED Review Details
11/09/2006 POST 3RD PARTY REVIEW 11/16/2006 COMPLETED Review Details
11/30/2006 RESUBMITTAL 11/30/2006 COMPLETED Review Details
11/30/2006 PLANS OK TO SUBMIT - SITE 11/30/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM04878
Permit Status: Final
Permit Description: TI: RESTAURANT R1-revision of mechanical,plumbing, & electrcial
Total Outstanding Activity Conditions - 1
Date Name
09/01/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM04878
Permit Description: TI: RESTAURANT R1-revision of mechanical,plumbing, & electrcial
Total Completed Inspections - 31
Date Description Inspector Results Comments
06/19/2007 ROOF NAILING GDABBS Approved IVRS - Inspection :*
ADDITIONAL PERLANS AT NEW RANGE HOOD & SHEATING
06/21/2007 FRAMING GDABBS Approved REMOVED WOOD STUD WALL AT OVERHEAD HOODS IN KITCHEN AND REPLACED WITH METAL STUD WALL - 20 GAUGE
06/26/2007 MECHANICAL - HOOD SYSTEMS JMILITEL Approved IVRS - Inspection :*
FIREWRAP OK
EXTEND STAINLESS 18" BEYOND ALL SIDES OF HOODS
06/27/2007 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
06/28/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
OK FOR CEILING TILES
07/02/2007 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
07/11/2007 FIRE SPKLR - FINAL LLAKEY Approved SEE SPRINKLER PERMIT APPROVALS
07/12/2007 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
SHALL SEE SAFETY CABLE ATTACHED FOR UNITS ON WHEELS
AND LISTING PLATES FOR NEW TILT SKILLETS
07/12/2007 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
SHALL SEE SAFETY CABLE ATTACHED FOR UNITS ON WHEELS
AND LISTING PLATES FOR NEW TILT SKILLETS
07/26/2007 NPPO - FINAL ACONNOR Approved N/A
07/26/2007 LANDSCAPE - FINAL ACONNOR Approved N/A
07/26/2007 NPPO - FINAL ACONNOR Approved
07/26/2007 RIGHT OF WAY - FINAL SDAMRON Approved PER EMAIL
07/26/2007 SIGN - FINAL JSONKIN Approved IVRS - Inspection :*
07/31/2007 FIRE - FINAL LLAKEY Approved
08/01/2007 PLUMBING - ABOVE CEILING RRICH Approved REVISED PLAN ON SITE
08/01/2007 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
REVISED PLAN ON SITE
08/01/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
08/01/2007 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
08/01/2007 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
08/01/2007 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :*
08/02/2007 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
08/02/2007 MECHANICAL - FINAL LHANLY Approved IVRS - Inspection :*
08/03/2007 MECHANICAL - HOODS LHANLY Approved
08/03/2007 MECHANICAL - INTERMEDIATE LHANLY Approved
09/26/2007 BUILDING - PROGRESS LHANLY Approved
09/26/2007 BUILDING ABOVE CEILING LHANLY Approved
09/28/2007 BUILDING - FINAL RRICH Approved IVRS - Inspection :*
09/28/2007 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
10/26/2007 ENGINEERING - FINAL NKALAHAR Approved CORRECTION NOTICE ISSUED 3 DAYS

-PLACE CONTROLS AROUND MATERIAL STOCKPILES
-CLEAN UP STUCCO/MORTAR WASHOUT
ENSURE ALL DRAINAGE/STORMDRAINS ARE PROTECTED
-ENSURE ALL WASHOUT-INCLUDING PAINT-IS CONTAINED PER EPA REGULATIONS

$75 RE-INSPECTION FEE AND NOTICE OF VIOLATION

FAXED INSPECTION TO 602-438-8183
12/29/2010 HEALTH DEPT - FINAL 724-7908 PCHEALTH Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
T06CM04878-R2_001.TIF CONSTRPLANS VIEW
T06CM04878-R_001.TIF CONSTRPLANS VIEW
T06CM04878-R_002.TIF CONSTRPLANS VIEW
T06CM04878-R_003.TIF CONSTRPLANS VIEW
T06CM04878-R_004.TIF CONSTRPLANS VIEW
T06CM04878-R_005.TIF CONSTRPLANS VIEW
T06CM04878-R_006.TIF CONSTRPLANS VIEW
T06CM04878-R_007.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL004.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL005.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL006.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL007.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL008.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL009.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL010.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL011.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL012.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL013.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL014.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL015.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL016.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL017.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL018.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL019.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL020.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL021.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL022.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL023.TIF CONSTRPLANS VIEW
4878-01-0001-01-ORIGINAL024.TIF CONSTRPLANS VIEW