Permit: T06CM00756
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
3931 E PARADISE FALLS DR
Address NEW:
3931 E PARADISE FALLS DR
Apply Date:
02/06/2006
Applicant:
BURLINI SILBERSCHLAG LTD
Description:
TI:OFFICE 63' x 60' ON FIRST FLOOR, 25' x 54' ON 2ND FLOOR. METAL STUDS W/ GYP BD
Contractors:
- RIO WEST DEVELOPMENT AND CONSTRU
Permit Reviews
Permit Number - T06CM00756
Permit Status: C of o
Permit Description: TI:OFFICE
63' x 60' ON FIRST FLOOR, 25' x 54' ON 2ND FLOOR. METAL STUDS W/ GYP BD
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/06/2006 | PLANS OK TO SUBMIT - COMM | 03/23/2006 | COMPLETED |
| 03/23/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 06/02/2006 | COMPLETED |
| 06/02/2006 | POST 3RD PARTY REVIEW | 10/19/2006 | COMPLETED |
| 06/07/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 06/13/2007 | COMPLETED |
| 10/22/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 10/22/2007 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM00756
Permit Description: TI:OFFICE
63' x 60' ON FIRST FLOOR, 25' x 54' ON 2ND FLOOR. METAL STUDS W/ GYP BD
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/19/2007 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* CALL FOR PRE-SLAB INSP. |
| 07/11/2007 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
| 08/07/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* OK TO SHEETROCK ONE SIDE |
| 08/30/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* OK TO COVER WALLS RECALL FOR CLOSET FLANGE INSP |
| 09/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | FOOTINGS FOR ELECTRIC SERVICE AREA OK TO POUR FOOTING PER PLAN DETAIL #10, PAGE A3.15 |
| 09/13/2007 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 10/01/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 10/01/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 11/08/2007 | ELECTRIC - ABOVE CEILING | IVR USER | Approved | IVRS - RI canceled |
| 11/09/2007 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* CONDUITS WITH OVER 360 DEG. TO HAVE CEILING J-BOXES INSTALLED, WILL CHECK ON CEILING INSPECTION OK WALL COVER |
| 11/28/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* ENSURE THAT A SPRINKLER HEAD IS INSTALLED IN STAIRWAY |
| 12/18/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILES |
| 12/18/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 12/20/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* OK FOR CEILING TILES |
| 02/06/2008 | TEP CLEARANCE - AM | BFLORES | Approved | OK TEMP POWER FOR TEST TMPP PER R.HOLLANDER |
| 03/21/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 03/21/2008 | FIRE - FINAL | LTHOMAS | Approved | |
| 08/12/2008 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | |
| 08/12/2008 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | |
| 08/12/2008 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 08/26/2008 | NPPO - FINAL | ACONNOR | Approved | |
| 08/26/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 08/29/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 08/29/2008 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 10/31/2008 | PERMIT FINALED | LJACKSON | Approved | |
| 10/31/2008 | ENGINEERING - FINAL | JSANDERS | Approved |