Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/09/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CONDUITS WITH OVER 360 DEG. TO HAVE CEILING J-BOXES INSTALLED, WILL CHECK ON CEILING INSPECTION OK WALL COVER |
|
| 11/08/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* FINISH PREVIOUS ITEMS |
|
| 11/06/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* LOCKED NO ACCESS |
|
| 10/30/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. PROTECT VDV CABLES IN WALLS FROM SHARP METAL EDGES 2. SUPPORT VDV CABLES IN WALLS & FLOOR 3. NO MORE THAN 360 DEG. IN CONDUIT RUNS 4. SUPPORT M/C CABLE WITHIN 12" OF BOXES 5. TIGHTEN LOOSE FITTINGS 6. WE HAVE BOXES OVERFILLED 7. SUPPORT CONDUITS ABOVE PANELS 8. PROTECT M/C CABLES IN STUD CHANNELS 9. FILL UNUSED OPENINGS |
|
| 09/20/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NO INTERMEDIATE WORK DONE |
|
| 09/19/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK LECTURE ROOM RECEPTACLES-CHECK REVISION FOR ADDITIONAL OUTLETS |
|
| 09/04/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UPSTAIRS LIDS |
|
| 08/23/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS |
|
| 08/21/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. PROTECT M/C CABLE IN CHANNELS OF STUDS 2. FINISH PREVIOUS ITEMS 1, 5 & 7 RECEIVED LETTER FROM MC CONDUITS & FITTINGS |
|
| 08/20/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |
|
| 08/16/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. SECURE MC CABLE WITHIN 12" OF BOXES -- 330.30 2. GROUND ALL METAL JUNCTION BOXES 3. PREVENT DI-ELECTRIC CONTACT 4. PROVIDE BACK BRACING TO PREVENT BOX MOVEMENT 5. TIGHTEN LOOSE FITTINGS & FULLY SEAT FITTINGS 6. PLANS CALL FOR 3/4" EMT MINIMUM & COMPRESSION FITTING 7. PROTECT PVC CONDUITS AT BASE PLATE 8. NEED AUTHORIZATION TO USE MC & PVC IN WALLS |
|
| 08/15/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELLED |