Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
DUPLEX NEW
Address NEW:
3428 E BERMUDA ST #01
Apply Date:
11/21/2005
Applicant:
CHRYSALIS LIVING DESIGN
Description:
NEW DUPLEX: TD#16-23-37 R1 As built site plan
Contractors:
  • M W 2 DEVELOPMENT CORPORATION

Permit Reviews

Permit Number - T05CM05814
Permit Status: Expired
Permit Description: NEW DUPLEX: TD#16-23-37 R1 As built site plan
Start Date Submittal Complete Date Status  
04/17/2006 RESUBMITTAL - SITE ALL 06/05/2006 COMPLETED Review Details
07/12/2006 RESUBMITTAL - SITE ALL 07/25/2006 COMPLETED Review Details
07/26/2006 RESUBMITTAL - SITE 08/02/2006 COMPLETED Review Details
08/01/2006 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 08/02/2006 COMPLETED Review Details
08/15/2006 REVISION - - 1ST 08/15/2006 COMPLETED Review Details
11/21/2005 PLANS OK TO SUBMIT - SITE 12/16/2005 COMPLETED Review Details
12/19/2005 SITE 02/02/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM05814
Permit Status: Expired
Permit Description: NEW DUPLEX: TD#16-23-37 R1 As built site plan
Total Outstanding Activity Conditions - 2
Date Name
11/21/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
07/13/2006 LANDSCAPE INSPECTOR MUST CHECK FOR PROTECTION OF TREES TO REMAIN IN PLACE PRIOR TO GRUBBING OR GRADING.

Outstanding Inspections

Permit Status: Expired
Permit Number: T05CM05814
Permite Description: NEW DUPLEX: TD#16-23-37 R1 As built site plan
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
NPPO PRE PERMIT INSPECTION N/A Not Inspected
03/15/2007 LANDSCAPE - FINAL N/A Not ready for Inspection
03/15/2007 NPPO - FINAL N/A Not ready for Inspection

Completed Inspections

Permit Status: Expired
Permit Number: T05CM05814
Permit Description: NEW DUPLEX: TD#16-23-37 R1 As built site plan
Total Completed Inspections - 24
Date Description Inspector Results Comments
08/16/2006 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
- WATER AND SEWER INSTALLED PER APPROVED SITE PLAN.
- CONNECTIONS TO EXISTING ABS @ EXISTING HOUSES ARE OK
- I WAS TOLD THAT A JOINT SEWER AGREEMENT IS REQUIRED WHEN MORE THAN 1 BUILDING IS CONNECTED TO A COMMON SEWER. PLEASE PROVIDE DOCUMENTATION FROM COUNTRY RECORDER.
09/19/2006 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
JOINT SEWER AGREEMENT REQUIRED FOR THREE SEPARATE BUILDINGS THAT SHARE A COMMON SEWER.
09/28/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
- USE THE ADHESIVE SEALANT ON YOUR ARMORFLEX TO COMPLETE THE JOB.
- PLEASE INSTALL HB VAC BREAKERS OR REMOVE HBS
- IN THE FUTURE I THINK THAT BOXING OUT FOR TUB P TRAPS WOULD BE BEST WHEN IN FOOTING.
09/29/2006 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection :*
OK 2 - #4 TO REBAR
10/06/2006 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
OK TO POUR
10/06/2006 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
ENSURE REBAR IS ELEVATED OFF THE GROUND
10/25/2006 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
11/06/2006 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
11/08/2006 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
1) OK INTERIOR WIRING COVER
2) NOTE: CHIME TRANSFORMER WIRING NOT COMPLETE LOW VOLTAGE AND LINE VOLTAGE AT CHIME ? RE-DO AS NEEDED
11/08/2006 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
11/15/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
T-STAT WIRE MUST BE INSIDE WALL PRIOR TO SHEETROCK.
ON FINAL BE SURE ALL T-TOPS HAVE SCREEN.
OK FOR SHEETROCK.
11/20/2006 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
11/20/2006 FRAMING AQUIROZ Approved IVRS - Inspection :*
11/21/2006 PLUMBING - INTERMEDIATE RMYERS Approved OK TO COVER ALL AREAS
12/06/2006 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
UNITS A & B
OK TO TAPE THROUGHOUT
03/01/2007 ELECTRIC - TEMPORARY SERVICE RHOLLAND Approved IVRS - Inspection :*
03/01/2007 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection :*
03/02/2007 TEP CLEARANCE - AM JWEATHER Approved TMPP CLEARED FOR #1 & #2 PER R. HOLLANDER
03/27/2007 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
03/27/2007 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
03/29/2007 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :*
03/30/2007 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
03/30/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
03/30/2007 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*

Documents