Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* - USE THE ADHESIVE SEALANT ON YOUR ARMORFLEX TO COMPLETE THE JOB. - PLEASE INSTALL HB VAC BREAKERS OR REMOVE HBS - IN THE FUTURE I THINK THAT BOXING OUT FOR TUB P TRAPS WOULD BE BEST WHEN IN FOOTING. |
|
| 09/27/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 3 OF THE 4 TUB P-TRAPS INSTALLED IN THE FOOTING HAVE BLACK PIPE SHOWING, ALSO THE TRAP ARMS INSTALLED THROUGH YOUR FOOTINGS SHOULD HAVE A THICKER WRAP, CODE DOES CALL FOR PIPING IN FOOTINGS TO BE SLEEVED. ALSO, POLY SLEEVING IS LISTED FOR USE ON METALLIC PIPES. PLASTIC PIPING EXPANDS AND CONTRACTS AT A MUCH HIGHER RATE. MY AQUA PEX BOOK HAS A PICTURE OF A RIGID SLEEVE OR ARMORFLEX. |
|
| 09/19/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* OK TO BACKFILL RECALL ROUGH PLUMBING INSPECTION PRIOR TO CONCRETE. POLY SLEEVING NOT ADEQUATE PROTECTION OF PEX TUBING PENETRATING SLAB. REFER TO PEX INSTALLATION INSTRUCTIONS. |