Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T05CM05814
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/13/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approv-Cond | |
| 07/13/2006 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | |
| 07/20/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Denied | To: MW2 DATE: July 21, 2006 FROM: Suzanne Bohnet, CFM Engineering Division SUBJECT: 3428 E. Bermuda St., Units 1 and 2 Duplex Site plan T05CM05814 (Third Review) RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please include a response letter to the comments along with the corrected copies of the SP with your next submittal. Site Plan: 1. Please provide the dimension from the street centerline to the curb on the Site Plan sheet. 2. Please provide the dimension from the street centerline to the proposed sidewalk. 3. The area between the sidewalk and curb scales to 2.5 feet and is labeled as 2 feet. Please clarify and ensure that the plan and label are consistent. 4. Please add the dimension from the property line to the sidewalk. 5. The enclosure for the refuse container must contain steel pipes or bollards between the container and the enclosure's rear and side walls to prevent damage while being serviced (DS 6-01.4.2.C.2). The inside dimension is 10'x10', which is inside the posts, not from wall to wall. This makes a minimum dimension for the refuse container enclosure 14' wide x11'8" deep. A detail of the container enclosure is included with the returned SP. Please revise the SP to accommodate these dimensions. After the corrections have been made, I will review this over the counter for approval. If you have any questions, please do not hesitate to contact me. Suzanne Bohnet, CFM, Engineer Associate (520) 791-5550 x1188 office Suzanne.Bohnet@tucsonaz.gov |
| 07/21/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: T05CM05814b 3428 E Bermuda St. No. 1 and 2 Site Plan - New Duplex and 2 existing Single Family residence buildings (Multifamily Development) TRANSMITTAL DATE: July 21, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. Due to remaining issues that must be addressed for engineering, zoning cannot approve the plans at this time. Also, the zoning comments were not addressed as requested. Zoning however, is willing to review and approve the plans over the counter when the remaining engineering issues and the requersted information by zoning have been provided/addressed or added to the plan as requested. 1. The previous comment has not been completely addressed. Per the response comments building floor plans were included with the re-submittal. The requested information was not in the package. Also the floor plans for the both the new and existing buildings should be drawn on the footprint drawing of the site plan or separate floor plan drawings should be included with the site plan package. Add or include the requested information. Previous Comment All existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use. It does not appear that the building footprints have been depicted on the plan as they exist on site. Indicate all existing porch structures, overhangs, carports, sheds etc and dimension the all the building footprints. Indicate the building height for each existing and proposed structure. Include in the next site plan submittal, dimensioned floor plan drawing of the existing buildings to verify the number of bedrooms and building square footages. DS 2-02.2.1.A.6 2. See comment which also relates to the previous comment. The number of parking spaces required cannot be verified until the requested floor plans for the existing and new buildings are submitted with the site plan package. (A portion of the previous comment has been left as reference for the reviewer.) Vehicle parking is based on the number of bedrooms per unit. The required parking cannot be verified until the floor plans for all the buildings are provided for review. DS 2-02.2.1.A.8 3. The zoning comments are minor in nature and the Zoning Reviewer with an appointment can review the revised site plan over the counter. If the applicant wishes to do so please call for an appointment once the plans have been revised and all outstanding zoning comments have been addressed. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\DSD\T05CM05814b.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 07/25/2006 | DAVID RIVERA | ZONING HC SITE | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/25/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 07/25/2006 | SUE REEVES | REJECT SHELF | Completed |