Permit: T05CM05773
Permit Details
Apply Date:
11/16/2005
Applicant:
BOB VOLSTEADT
Description:
RECREATION CENTER:NEW
Contractors:
- PULTE HOME CORPORATION ARIZONA *C
Permit Reviews
Permit Number - T05CM05773
Permit Status: C of o
Permit Description: RECREATION CENTER:NEW
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/14/2006 | RESUBMITTAL | 02/15/2006 | COMPLETED |
02/15/2006 | RESUBMITTAL | 04/24/2006 | COMPLETED |
05/16/2006 | RESUBMITTAL | 06/15/2006 | COMPLETED |
06/15/2006 | RESUBMITTAL | 06/21/2006 | COMPLETED |
06/22/2006 | RESUBMITTAL | 06/22/2006 | COMPLETED |
06/22/2006 | RESUBMITTAL | 07/10/2006 | COMPLETED |
11/02/2006 | REVISION - - 1ST | 11/02/2006 | COMPLETED |
11/16/2005 | PLANS OK TO SUBMIT - COMM | 12/02/2005 | COMPLETED |
12/02/2005 | COMMERCIAL NEW | 01/19/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05773
Permit Status: C of o
Permit Description: RECREATION CENTER:NEW
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
11/16/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM05773
Permit Description: RECREATION CENTER:NEW
Total Completed Inspections - 45
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2006 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | Need plan and permit for fire service underground pipe. |
10/12/2006 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | THIS INSPECTION FOR 3" CW STUBBED UP AND OUT AT SOUTH WEST CORNER 100 PSI AIR TEST APP 5 OK |
10/13/2006 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* |
10/18/2006 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* MAIN SLAB FOR COMMUNITY CENTER BUILDING |
10/18/2006 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* MAIN SLAB FOR COMMUNITY CENTER BUILDING |
10/18/2006 | ELECTRIC - UFER | GDABBS | Approved | IVRS - Inspection :* |
10/18/2006 | ELECTRIC - UFER | RSUBA | Approved | IVRS - Inspection :* |
11/16/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
11/22/2006 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
12/05/2006 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* 4" SDR 35 FROM PUBLIC MANHOLE #12 EAST WITH (3) IN LINE CLEANOUTS TO 15' FROM BUILDING BEDDING, LAYING, TRACER WIRE OK SHADING ON SITE, SHALL AIR TEST AT LATER DATE & PROVIDE AUTHORIZATION TO DISCHARGE FOR MANHOLE #12 PIMA COUNTY & PCDEQ FOR TIE IN AT BUILDING. |
12/13/2006 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1. SUPPLY & EXHAUST IN RESTROOMS 2. OK TO SHEETROCK 3. CHECKED CONDENSATE DRAINS. |
12/14/2006 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
12/15/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* CLOSET FLANGES OK |
12/15/2006 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 15 PSI TEST FROM METER LOCATION TO (2) ROOFTOP UNITS (CAPPED) |
12/15/2006 | PLUMBING - PROGRESS | RRICH | Approved | WATER TEST WASTE & VENT THRU ROOF OK WATER PIPING AIR TEST OK 1. SHALL SEE TUBULAR TRAP & ACCESS PANEL AT EVAC 2. CLOSET FLANGES TO HAVE DUTCHMEN 3. TRAP PRIMER INSTALL CORRECTLY |
12/18/2006 | PLUMBING - ROOF DRAINS | RRICH | Approved | WATER TEST 3" RD & 3" OFRD (2) LOCATIONS OK |
12/19/2006 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* INSIDE & OUTSIDE |
12/20/2006 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* 1. SCREEN WALL FOOTING FOR ELECT. SWITCH GEAR NORTH SIDE 2. SCREEN WALL FOOTING FOR POOL EQUIP. - SOUTH SIDE |
12/20/2006 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* OK 2 -4" PVC OUT 20' FROM BUILDING |
01/04/2007 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
01/04/2007 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
01/08/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
01/30/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | OK FOR CEILING TILES |
04/05/2007 | ELECTRIC - CONSTRUCTION POWER | IVR USER | Approved | IVRS - AP canceled |
04/06/2007 | ELECTRIC - TEMP POWER FOR TEST | RJIROUDE | Approved | IVRS - Inspection :* |
04/06/2007 | ELECTRIC - CABLE DROP | RJIROUDE | Approved | IVRS - Inspection :* |
04/09/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. JIROUDEK |
04/12/2007 | OUTDOOR LIGHTING FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
04/13/2007 | RIGHT OF WAY - FINAL | SDAMRON | Approved | |
04/13/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
04/13/2007 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
04/13/2007 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
04/13/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
04/13/2007 | FIRE - FINAL | LTHOMAS | Approved | |
04/20/2007 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
04/23/2007 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | |
05/10/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* OK FOR FINAL AIR BALANCE OK |
06/29/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* RECEIVED BACTERIA REPORT RECEIVED HCS RELEASE FROM PIMA COUNTY |
07/03/2007 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
07/03/2007 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* |
07/05/2007 | NPPO - FINAL | ACONNOR | Approved | |
07/05/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
07/11/2007 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* OK FOR C OF O |
08/22/2007 | ENGINEERING - FINAL | JBRUCKME | Approved | |
08/22/2007 | PERMIT FINALED | JBRUCKME | Approved |