Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM05773

Parcel: 141353620

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T05CM05773

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
02/23/2007 PLUMBING - PROGRESS Approved IVRS - Inspection :*
01/18/2007 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
SHALL HAVE ACCESS TO APPROVED SITE PLAN AND TEST IN PLACE AT TIME OF INSPECTION.
12/15/2006 PLUMBING - PROGRESS Partial Approval WATER TEST WASTE & VENT THRU ROOF OK
WATER PIPING AIR TEST OK
1. SHALL SEE TUBULAR TRAP & ACCESS PANEL AT EVAC
2. CLOSET FLANGES TO HAVE DUTCHMEN
3. TRAP PRIMER INSTALL CORRECTLY
11/21/2006 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
SITE SEWER PRE-CONSTRUCTION
MEETING WITH LEO BORDERLAND, BRIAN T.L ROOF
4" BUILDING SEWER TO MEET 2003 UPC MINIMUM REQUIREMENTS.