Permit: T05CM05097
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
3655 N FLOWING WELLS RD
Address NEW:
3655 N FLOWING WELLS RD
Apply Date:
10/06/2005
Applicant:
SHARON BONESTEEL
Description:
TI: DAY CARE REMODEL INTERIOR : 2 ACCESSIBILE TOILET ROOMS,CERAMIC TILE FLOOR W/ FRP TO 4 FEET UP WALL ON WATER- RESISTANT GYP BD, WOOD STUDS AND JOISTS W/ GYP BD..
Contractors:
- FARWEST DEVELOPMENT AND CONSTRUCTION OF THE SOUT
Permit Reviews
Permit Number - T05CM05097
Permit Status: C of o
Permit Description: TI: DAY CARE
REMODEL INTERIOR :
2 ACCESSIBILE TOILET ROOMS,CERAMIC TILE FLOOR W/ FRP TO 4 FEET UP WALL ON WATER- RESISTANT GYP BD, WOOD STUDS AND JOISTS W/ GYP BD..
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/06/2005 | COMMERCIAL TI | 12/08/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM05097
Permit Status: C of o
Permit Description: TI: DAY CARE
REMODEL INTERIOR :
2 ACCESSIBILE TOILET ROOMS,CERAMIC TILE FLOOR W/ FRP TO 4 FEET UP WALL ON WATER- RESISTANT GYP BD, WOOD STUDS AND JOISTS W/ GYP BD..
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/06/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM05097
Permit Description: TI: DAY CARE
REMODEL INTERIOR :
2 ACCESSIBILE TOILET ROOMS,CERAMIC TILE FLOOR W/ FRP TO 4 FEET UP WALL ON WATER- RESISTANT GYP BD, WOOD STUDS AND JOISTS W/ GYP BD..
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2005 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :*NOT INSTALLED PER PLAN NO REDLINES ON SITE REINSPECTED 3:20 PM REINSPECTED 4:15 PM ABS DWV UNDERSLAB OK OK TO COVER REDLINE CHANGES TO PLAY YARDWATER FROM METER THRU RPPBP TO P.O.C TO EXISTING OK OK TO COVER |
| 12/14/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 12/14/2005 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1. REMOVE BLAKE TEE AND INSTALL DIRECTIONAL FITTING - MAKE ALL CONNECTIONS, TEST ALL PIPE |
| 12/22/2005 | ELECTRIC - SERVICE UPGRADE | CCLEMENS | Approved | IVRS - Inspection :*SERVICE OK TO BE ENERGIZED FOR THE PURPOSE OF CHANGE OVER. CALL FOR COMPLETE SERVICE AND BRANCH CKT INSPECTION WHEN COMPLETE |
| 12/23/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | INCR |
| 12/28/2005 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/20/2006 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :*HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP LAVATORY TRAP ARM TO BE 1 1/2" ( MAX 3" 6" DEV. LENGTH) SECURE CLOSET FLANGES OVEHEAD PIPING TO BE SUPPORTED PER TABLE 3-1 |
| 01/23/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/24/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/01/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 02/01/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 02/02/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* CLOSET FLANGES OK |
| 02/10/2006 | FIRE - FINAL | LLAKEY | Approved | |
| 02/10/2006 | FIRE - ALARM FINAL | LLAKEY | Approved | |
| 02/17/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
| 02/21/2006 | ENGINEERING - FINAL | DROBERTS | Approved | PER PHONE CALL |
| 02/21/2006 | SIGN - FINAL | JYBARRA | Approved | |
| 02/21/2006 | BUILDING - FINAL | AQUIROZ | Approved | |
| 02/21/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | |
| 02/21/2006 | ELECTRIC - FINAL | CCLEMENS | Approved |