Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2006 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 01/19/2006 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :*CHECKED 3 NEW BATHROOM EXHAUST FANS. OK TO COMPLETE CEILING |