Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
6135 E 22ND ST
Address NEW:
6135 E 22ND ST
Apply Date:
09/07/2005
Applicant:
GOLDSTEIN, GENE
Description:
FIRE DAMAGE REPAIR - RESTAURANT
Architects:
  • GOLDSTEIN, GENE
Contractors:
  • GOLDSTEIN CONSTRUCTION MANAGEMEN

Permit Reviews

Permit Number - T05CM04615
Permit Status: Final
Permit Description: FIRE DAMAGE REPAIR - RESTAURANT
Start Date Submittal Complete Date Status  
04/05/2006 REVISION - WALK THRU 04/05/2006 COMPLETED Review Details
04/18/2006 REVISION - WALK THRU 04/18/2006 COMPLETED Review Details
09/07/2005 COMMERCIAL TI 11/09/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM04615
Permit Status: Final
Permit Description: FIRE DAMAGE REPAIR - RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
09/07/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05CM04615
Permit Description: FIRE DAMAGE REPAIR - RESTAURANT
Total Completed Inspections - 16
Date Description Inspector Results Comments
11/22/2005 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*MINIMUM 12" TALL ADDRESS DISPLAY REQUIRED.
11/22/2005 FRAMING LHANLY Approved IVRS - Inspection :*
11/23/2005 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*EXISTING GREASE DUCTS & SHAFTS OK
CONDENSATE FROM A/C UNIT CANNOT TERMINATE INTO A SEWER VENT. RUN DRAIN FROM A/C & MAKE UP AIR UNIT DOWN INTO KITCHEN & TERMINATE INTO THE FLOOR DRAIN. VENT CONNECTOR ON WATER HEATER MUST BE 3" NOT 4". PROVIDE A LOW COMBUSTION AIR VENT IN WATER HEATER ROOM
11/23/2005 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
11/23/2005 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved A PLAN & PERMIT IS REQUIRED FOR HOOD
11/30/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
12/07/2005 ENGINEERING - FINAL NKALAHAR Approved BOTTOM OF HANDICAPPED PARKING SIGN NEEDS TO BE AT 84"
01/10/2006 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) ON FINAL FINISH CONNECTING MAKE UP AIR UNIT
01/10/2006 ELECTRIC - FINAL RMAJUTA Approved PER INSP CARD
01/10/2006 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
ELECTRICAL CONTRACTOR WORK FINISHED MECH LV CONNECTION TO BE BY MECH. CONTRACTOR
05/22/2006 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
UNDERGROUND ROUGH SOIL OK
PROVIDE PIPE WRAPS THRU CONCRETE.
1. PROVIDE P-TRAP ON INDIRECT DRAIN FROM SANITIZER BOWL WITH CLEANOUT FOR OVER 5'.
2. PROVIDE 1/4" PER FOOT FALL ON TRAP ARM OF 2-COMPS OF 3 COMP SINK.
3. VENT FROM FLOW CONTROL TO BE PER PLAN.
4. HAND SINK SHALL HAVE LONG RADIUS DRAINAGE FITTINGS.
5. VENT FROM WATER HEATER TO BE 2' ABOVE TOP OF PARAPET WHEN WITHIN 8'
15 PSI TEST FROM METER THRU NO ANSUL VALVE INSTALLED NOW.
05/25/2006 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
APPROVED PER APPROVED PLAN.
05/25/2006 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
06/01/2006 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RECEIVED (2) IN HOUSE BACKFLOW CERTIFICATIONS (1) FOR ICE MAKER (1) FOR CARBONATOR (ONLY)
06/06/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
OK FOR FINAL
06/07/2006 FIRE - FINAL LLAKEY Approved

Documents

File Name Document Type  
T05CM04615 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
None LETTER OF COMPLETION VIEW
None DOCUMENTS VIEW