Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Address NEW:
1790 W SAHUARO DR
Apply Date:
08/12/2005
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
ADD: TRADE SERVICE & REPAIR WORKSPACE REPAIR AND SERVICING OF SMALL DRILL RIGS.

Permit Reviews

Permit Number - T05CM04237
Permit Status: C of o
Permit Description: ADD: TRADE SERVICE & REPAIR WORKSPACE REPAIR AND SERVICING OF SMALL DRILL RIGS.
Start Date Submittal Complete Date Status  
08/12/2005 PLANS OK TO SUBMIT - 3RD PARTY 08/15/2005 COMPLETED Review Details
08/15/2005 3RD PARTY REVIEW-COMMERCIAL 09/22/2005 COMPLETED Review Details
09/22/2005 POST 3RD PARTY REVIEW 09/28/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05CM04237
Permit Status: C of o
Permit Description: ADD: TRADE SERVICE & REPAIR WORKSPACE REPAIR AND SERVICING OF SMALL DRILL RIGS.
Total Outstanding Activity Conditions - 1
Date Name
08/12/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM04237
Permit Description: ADD: TRADE SERVICE & REPAIR WORKSPACE REPAIR AND SERVICING OF SMALL DRILL RIGS.
Total Completed Inspections - 38
Date Description Inspector Results Comments
10/18/2005 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*
12/09/2005 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*DOWN SPOUT MATERIAL TO BE CAST IRONG CLOSET FLANGE
INSULATE COLD
12/21/2005 MECHANICAL - PROGRESS JMILITEL Approved IVRS - Inspection :*
WORK IS PROGRESSING - OK TO PROCEED
12/21/2005 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*
THERE MAY NO BE ANY CONNECTIONS BETWEEN THE METER AND THE RPPBP
12/21/2005 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
12/22/2005 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
12/22/2005 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
12/22/2005 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
12/22/2005 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
YARDWATER - OK
CLOSET FLANGE - OK
12/22/2005 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
12/22/2005 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
12/22/2005 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
12/22/2005 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
12/22/2005 FRAMING AQUIROZ Approved IVRS - Inspection :*
12/22/2005 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
12/22/2005 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
12/22/2005 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
12/22/2005 ENGINEERING - FINAL MRUSSO Approved
12/23/2005 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :*MAY NOT CUT ABS INTO SIDE OF SQUARE DOWN SPOUT
GUTTER NOT CONNECTED TO DRAIN
12/28/2005 ELECTRIC - UNDERGROUND CCLEMENS Approved IVRS - Inspection :*
1) NEED MINIMUM #4 CU GROUND TAP TO PANEL "C" DISCONNECT
2) NEED MINIMUM 2/0 CU TO BOND BLDG STEEL AND METAL PIPE SYSTEMS
12/28/2005 SIGN - FINAL JYBARRA Approved IVRS - Inspection :* NEED TO PERMIT EXST DOOR SIGN AND REMOVE EXST SF ON SITE OR OBTAIN PERMITS
12/28/2005 OUTDOOR LIGHTING FINAL CCLEMENS Approved IVRS - Inspection :*
12/28/2005 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :*
12/28/2005 ELECTRIC - OUTDOOR LIGHTING CCLEMENS Approved IVRS - Inspection :$
12/28/2005 ELECTRIC - PROGRESS CCLEMENS Approved IVRS - Inspection :*
12/28/2005 ELECTRIC - TEMP POWER FOR TEST CCLEMENS Approved IVRS - Inspection :
The service is not per code.| 210*
12/28/2005 ELECTRIC - CONSTRUCTION POWER CCLEMENS Approved IVRS - Inspection :
The service is not per code.| 210*
12/28/2005 ELECTRIC - CABLE DROP CCLEMENS Approved IVRS - Inspection :
The service is not per code.| 210*
12/28/2005 ELECTRIC - ABOVE CEILING CCLEMENS Approved IVRS - Inspection :*
12/28/2005 ELECTRIC - INTERMEDIATE CCLEMENS Approved IVRS - Inspection :*
12/29/2005 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*OK FOR FINAL C OF O
12/29/2005 ELECTRIC - SERVICE UPGRADE CCLEMENS Approved IVRS - Inspection :*OK TO ENERGIZE SERVICE FOR CHANGE OVER
12/30/2005 TEP CLEARANCE - AM JKOZUCH Approved ECO
01/18/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*I REC'D LETTER APPROVING ABS ON RNL & COLD WATER INSULATION DELETED INSIDE
PLUMBING FINAL OK
OK FOR C OF O PENDING ANY OTHER INSPECTION
01/26/2006 NPPO - FINAL ACONNOR Approved
02/16/2006 LANDSCAPE - FINAL ACONNOR Approved
05/31/2006 BUILDING - FINAL AQUIROZ Approved
06/21/2006 PERMIT FINALED AKLAPPE Approved