Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
3925 E GRANT RD
Address NEW:
3925 E GRANT RD
Apply Date:
01/22/2004
Applicant:
THE PLANNING CENTER
Description:
TI:RETAIL
Contractors:
  • BATEMAN HALL INC ,

Permit Reviews

Permit Number - T04CM00284
Permit Status: C of o
Permit Description: TI:RETAIL
Start Date Submittal Complete Date Status  
01/03/2005 REVISION 02/16/2005 COMPLETED Review Details
01/05/2005 REVISION - WALK THRU 01/05/2005 COMPLETED Review Details
01/22/2004 SITE 02/25/2004 COMPLETED Review Details
03/09/2004 PLANS OK TO SUBMIT - COMM 03/09/2004 COMPLETED Review Details
03/09/2004 COMMERCIAL TI 04/12/2004 COMPLETED Review Details
03/11/2004 RESUBMITTAL - SITE 06/09/2004 COMPLETED Review Details
05/05/2004 RESUBMITTAL 06/09/2004 COMPLETED Review Details
05/11/2005 REVISION 05/11/2005 COMPLETED Review Details
05/11/2005 REVISION 05/18/2005 COMPLETED Review Details
06/21/2004 RESUBMITTAL 07/14/2004 COMPLETED Review Details
07/23/2004 RESUBMITTAL 07/29/2004 COMPLETED Review Details
07/29/2004 COMMERCIAL NEW 09/07/2004 COMPLETED Review Details
09/07/2004 RESUBMITTAL 10/13/2004 COMPLETED Review Details
10/13/2004 REVISION - WALK THRU 10/13/2004 COMPLETED Review Details
10/13/2004 REVISION 11/08/2004 COMPLETED Review Details
12/21/2004 PLANS OK TO SUBMIT - COMM 12/30/2004 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T04CM00284
Permit Description: TI:RETAIL
Total Completed Inspections - 37
Date Description Inspector Results Comments
11/18/2004 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved Need plan submittal and permit for underground fire sprinkler piping.
11/18/2004 ELECTRIC - UFER RSUBA Approved OK UFER @ SOUTH END PER NEC & APPROVED PLAN
11/18/2004 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection :*/OK 3/0 TO REBAR FOR BONDING JUMPER SOUTHSIDE COL #
12/14/2004 ROOF NAILING HLEYVA Approved IVRS - Inspection :*
1) EXCEPT FRONT AND DRIVE THRU
12/17/2004 EXCAVATION/LAYOUT REBAR & ZON HLEYVA Approved IVRS - Inspection :*/OK LEGS? @ FRONT
12/20/2004 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved IVRS - Inspection :*/NEED TO SEE CONNECTION BETWEEN BLDG DRAIN & HCS
12/20/2004 REINFORCED MASONRY PRE-GROUT HLEYVA Approved IVRS - Inspection :*
12/23/2004 STEM WALL/RETAINING WALL HLEYVA Approved IVRS - Inspection :*
1) ? AT DRIVE THROUGH, FREEZER FLOOR AND SLABS AT DECK
12/23/2004 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
1) OK 3/4" AND 1" PVC FROM ED2 OUT TO EQUIPMENT
12/23/2004 STEM WALL/RETAINING WALL HLEYVA Approved IVRS - Inspection :*
12/27/2004 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection :*/PLEASE PROVIDE A SET OF APPROVED REVISED PLANS BEFORE NEXT INSP. REVISION ON UNDERGROUND AT THIS TIME NOT READY
02/23/2005 TEP CLEARANCE - AM RMAJUTA Approved OK-TEMP POWER FOR TESR ON BOND PER SANTA CRUZ
03/01/2005 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
03/24/2005 FIRE SPKLR - FINAL LTHOMAS Approved
03/24/2005 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
03/25/2005 RIGHT OF WAY - FINAL PWHIDDON Approved
03/25/2005 SIGN - FINAL RDEAR Approved IVRS - Inspection :*
03/30/2005 FRAMING BSTEVENS Approved IVRS - Inspection :*
03/30/2005 BUILDING PRE-SLAB BSTEVENS Approved IVRS - Inspection :*
04/14/2005 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
04/14/2005 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
04/14/2005 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
04/21/2005 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
04/22/2005 FIRE - FINAL LLAKEY Approved
04/26/2005 LANDSCAPE - FINAL ACONNOR Approved
04/28/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
04/28/2005 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*
04/28/2005 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection :*
05/19/2005 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection :*
1) EXCEPT FOR ROOF DRAINS BY OTHERS
06/08/2005 PLUMBING - PROGRESS TRINIVJR Approved
06/08/2005 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved
06/08/2005 PLUMBING - ROOF DRAINS TRINIVJR Approved
06/08/2005 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :*
1) PLUMBING FINAL IS OK
2) OK FOR C OF O
06/14/2005 ENGINEERING - FINAL JBRUCKME Approved
06/16/2005 PERMIT FINALED LJACKSON Approved
06/16/2005 BUILDING - FINAL HLEYVA Approved
06/16/2005 SHEET ROCK NAILING HLEYVA Approved